Literature DB >> 2688252

Duplex Doppler ultrasound in determination of renal artery stenosis.

K W Sievers1, E Löhr, W R Werner.   

Abstract

Twenty-six cases of renal artery stenosis were evaluated with Doppler ultrasound using the pulsatile flow index (PFI). To establish normal values, the PFI in 60 renal arteries in 30 healthy volunteers was obtained. Normal values by PFI ranged between 0.48 and 0.71 (mean +/- SD: 0.6 +/- 0.06). In renal artery stenosis the PFI range was 0.72-0.79. The normal upper limit was 0.71. The PFI failed in three patients; however, an ultrasound examination showed secondary renal disease (two patients with stenosis on both sides with a shrunken kidney on one side, and one patient with hypernephroma on the opposite side). The PFI was normal (14 of 14 patients) in patients without angiographic evidence of stenosis or after successful dilatation.

Entities:  

Mesh:

Year:  1989        PMID: 2688252     DOI: 10.1007/bf02926499

Source DB:  PubMed          Journal:  Urol Radiol        ISSN: 0171-1091


  2 in total

1.  [Screening and diagnosis for eliminating renovascular hypertension. Value of 24-hour blood pressure monitoring and color-coded duplex ultrasound diagnosis].

Authors:  K L Schulte; K P Spies; D van Gemmeren; T Lenz; R Gotzen; A Distler; F Fobbe
Journal:  Med Klin (Munich)       Date:  1997-06-15

2.  Doppler studies in normal kidneys of healthy children.

Authors:  T Scholbach
Journal:  Pediatr Nephrol       Date:  1996-04       Impact factor: 3.714

  2 in total