| Literature DB >> 26878851 |
M Willegger1, E Benca1, L Hirtler2, K Hradecky1, J Holinka1, R Windhager1, R Schuh3.
Abstract
PURPOSE: Current methods of anterior talofibular ligament (ATFL) reconstruction fail to restore the stability of the native ATFL. Therefore, augmented anatomic ATFL reconstruction gained popularity in patients with attenuated tissue and additional stress on the lateral ankle ligament complex. The aim of the present study was to evaluate the biomechanical stability of the InternalBrace (Arthrex Inc., Naples, FL, USA), a tape augmentation designed to augment the traditional Broström procedure.Entities:
Keywords: Anterior talofibular ligament reconstruction; Biomechanical stability; Bone mineral density; Lateral ankle instability; Tape augmentation
Mesh:
Year: 2016 PMID: 26878851 PMCID: PMC4823330 DOI: 10.1007/s00167-016-4048-7
Source DB: PubMed Journal: Knee Surg Sports Traumatol Arthrosc ISSN: 0942-2056 Impact factor: 4.342
Fig. 1Surgical exposure before dissection of the ATFL in a right ankle specimen from the IB group. A curved haemostat is placed under the anterior talofibular ligament (ATFL). IER inferior extensor retinaculum, PLT peroneus longus tendon, PBT peroneus brevis tendon
Fig. 2Biomechanical test set-up: Wood’s metal and a custom-made steel cup (1) were used for proximal fixation. A Kirschner wire (2) prevented relative tibiofibular movement. The lower leg specimen (3) was mounted into the testing platform (4) using a Kirschner wire (5) drilled through the calcaneus and locked into the guide block (6) of the mounting platform
Fig. 3a and b Schematic drawing of the native ATFL (a) (group ATFL) and the InternalBrace® (Arthrex Inc., Naples, FL, USA) tape augmentation (b) (group IB)
Descriptive data of the tested ankle specimens
| Group | Intact ATFL ( | Tape augmentation (InternalBrace) ( |
|
|---|---|---|---|
| Age (years) | 76.6 ± 12.8 | 79.6 ± 11.2 | n.s. |
| BMD (g/cm2) | 0.46 ± 0.18 | 0.44 ± 0.16 | n.s. |
| Sex (male/female) | 3 m/3 f | 3 m/3 f | n.s. |
| Side (left/right) | 2 l/4 r | 4 l/2 r | n.s. |
Mean values and standard deviations of maximal tolerated torque to failure and failure angle at maximum tolerated torque to failure
| Group | Intact ATFL ( | Tape augmentation (InternalBrace) ( |
|
|---|---|---|---|
| Max. failure torque (Nm) | 8.3 ± 4.5 | 11.2 ± 7.1 | n.s. |
| Failure angle (°) | 33 ± 10 | 46 ± 16 | n.s. |