Literature DB >> 26878107

Performance of in-pixel circuits for photon counting arrays (PCAs) based on polycrystalline silicon TFTs.

Albert K Liang1, Martin Koniczek, Larry E Antonuk, Youcef El-Mohri, Qihua Zhao, Robert A Street, Jeng Ping Lu.   

Abstract

Photon counting arrays (PCAs), defined as pixelated imagers which measure the absorbed energy of x-ray photons individually and record this information digitally, are of increasing clinical interest. A number of PCA prototypes with a 1 mm pixel-to-pixel pitch have recently been fabricated with polycrystalline silicon (poly-Si)-a thin-film technology capable of creating monolithic imagers of a size commensurate with human anatomy. In this study, analog and digital simulation frameworks were developed to provide insight into the influence of individual poly-Si transistors on pixel circuit performance-information that is not readily available through empirical means. The simulation frameworks were used to characterize the circuit designs employed in the prototypes. The analog framework, which determines the noise produced by individual transistors, was used to estimate energy resolution, as well as to identify which transistors contribute the most noise. The digital framework, which analyzes how well circuits function in the presence of significant variations in transistor properties, was used to estimate how fast a circuit can produce an output (referred to as output count rate). In addition, an algorithm was developed and used to estimate the minimum pixel pitch that could be achieved for the pixel circuits of the current prototypes. The simulation frameworks predict that the analog component of the PCA prototypes could have energy resolution as low as 8.9% full width at half maximum (FWHM) at 70 keV; and the digital components should work well even in the presence of significant thin-film transistor (TFT) variations, with the fastest component having output count rates as high as 3 MHz. Finally, based on conceivable improvements in the underlying fabrication process, the algorithm predicts that the 1 mm pitch of the current PCA prototypes could be reduced significantly, potentially to between ~240 and 290 μm.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26878107      PMCID: PMC5503204          DOI: 10.1088/0031-9155/61/5/1968

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

Review 2.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach.

Authors:  L Abbene; G Gerardi; F Principato; S Del Sordo; R Ienzi; G Raso
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

4.  Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.

Authors:  Polad M Shikhaliev; Shannon G Fritz
Journal:  Phys Med Biol       Date:  2011-03-02       Impact factor: 3.609

5.  Modeling the performance of a photon counting x-ray detector for CT: energy response and pulse pileup effects.

Authors:  Katsuyuki Taguchi; Mengxi Zhang; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; Einar Nygard; Neal E Hartsough; Benjamin M W Tsui; William C Barber
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors.

Authors:  Youcef El-Mohri; Larry E Antonuk; Martin Koniczek; Qihua Zhao; Yixin Li; Robert A Street; Jeng-Ping Lu
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

  6 in total
  1 in total

1.  Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.

Authors:  Martin Koniczek; Larry E Antonuk; Youcef El-Mohri; Albert K Liang; Qihua Zhao
Journal:  Med Phys       Date:  2017-05-22       Impact factor: 4.071