Clinical results with titanium crowns fabricated with machine duplication and spark erosion.

M Andersson1, B Bergman, C Bessing, G Ericson, P Lundquist, H Nilson.   

Abstract

A new method for fabrication of metal crowns has been developed by one of the authors (M.A.). There are two principles involved: machine duplication of models and electric discharge machining. The metal used is pure unalloyed titanium, which is processed as a coping and later covered by a composite resin. In 1986, 205 separate titanium crowns were made on 149 patients. One year later 192 crowns on 137 patients could be examined. Five crowns had been replaced by new ones owing to fracture of the composite resin. In accordance with the CDA quality evaluation system the following results were obtained for the remaining 187 crowns: margin integrity, 186 excellent or satisfactory (99.5%); anatomic form, 185 excellent or satisfactory (98.9%); and surface and color, 181 excellent or satisfactory results (96.8%). The 1-year results are promising, and further follow-up studies will be made.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2686338     DOI: 10.3109/00016358909007713

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  5 in total

1.  Multitechnique characterization of CPTi surfaces after electro discharge machining (EDM).

Authors:  Spiros Zinelis; Youssef S Al Jabbari; Andrew Thomas; Nick Silikas; George Eliades
Journal:  Clin Oral Investig       Date:  2013-03-17       Impact factor: 3.573

Review 2.  Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports.

Authors:  Telma Dantas; Sara Madeira; Michael Gasik; Paula Vaz; Filipe Silva
Journal:  Materials (Basel)       Date:  2021-04-29       Impact factor: 3.623

3.  Use of zinc phosphate cement as a luting agent for Denzir trade mark copings: an in vitro study.

Authors:  Karl-Johan M Söderholm; Eduardo Mondragon; Ileana Garcea
Journal:  BMC Oral Health       Date:  2003-02-07       Impact factor: 2.757

4.  Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest.

Authors:  Jinshuang Wu; Xianli Wang; Helin Xing; Tianwen Guo; Chaofang Dong; Sefei Yang
Journal:  Biomed Res Int       Date:  2017-08-23       Impact factor: 3.411

5.  Trace elements can influence the physical properties of tooth enamel.

Authors:  Elnaz Ghadimi; Hazem Eimar; Benedetto Marelli; Showan N Nazhat; Masoud Asgharian; Hojatollah Vali; Faleh Tamimi
Journal:  Springerplus       Date:  2013-10-02
  5 in total