Improved mass resolution and mass accuracy in TOF-SIMS spectra and images using argon gas cluster ion beams.

Hyun Kyong Shon1, Sohee Yoon1, Jeong Hee Moon2, Tae Geol Lee3.   

Abstract

The popularity of argon gas cluster ion beams (Ar-GCIB) as primary ion beams in time-of-flight secondary ion mass spectrometry (TOF-SIMS) has increased because the molecular ions of large organic- and biomolecules can be detected with less damage to the sample surfaces. However, Ar-GCIB is limited by poor mass resolution as well as poor mass accuracy. The inferior quality of the mass resolution in a TOF-SIMS spectrum obtained by using Ar-GCIB compared to the one obtained by a bismuth liquid metal cluster ion beam and others makes it difficult to identify unknown peaks because of the mass interference from the neighboring peaks. However, in this study, the authors demonstrate improved mass resolution in TOF-SIMS using Ar-GCIB through the delayed extraction of secondary ions, a method typically used in TOF mass spectrometry to increase mass resolution. As for poor mass accuracy, although mass calibration using internal peaks with low mass such as hydrogen and carbon is a common approach in TOF-SIMS, it is unsuited to the present study because of the disappearance of the low-mass peaks in the delayed extraction mode. To resolve this issue, external mass calibration, another regularly used method in TOF-MS, was adapted to enhance mass accuracy in the spectrum and image generated by TOF-SIMS using Ar-GCIB in the delayed extraction mode. By producing spectra analyses of a peptide mixture and bovine serum albumin protein digested with trypsin, along with image analyses of rat brain samples, the authors demonstrate for the first time the enhancement of mass resolution and mass accuracy for the purpose of analyzing large biomolecules in TOF-SIMS using Ar-GCIB through the use of delayed extraction and external mass calibration.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26861497     DOI: 10.1116/1.4941447

Source DB:  PubMed          Journal:  Biointerphases        ISSN: 1559-4106            Impact factor:   2.456


  6 in total

1.  Temperature Dependence of Arn+ Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature.

Authors:  Claude Poleunis; Vanina Cristaudo; Arnaud Delcorte
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-27       Impact factor: 3.109

Review 2.  Mass Spectrometry Imaging: A Review of Emerging Advancements and Future Insights.

Authors:  Amanda Rae Buchberger; Kellen DeLaney; Jillian Johnson; Lingjun Li
Journal:  Anal Chem       Date:  2017-12-13       Impact factor: 6.986

Review 3.  Biological tissue sample preparation for time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging.

Authors:  Sohee Yoon; Tae Geol Lee
Journal:  Nano Converg       Date:  2018-09-25

4.  (CO2)n+, (H2O)n+, and (H2O)n+ (CO2) gas cluster ion beam secondary ion mass spectrometry: analysis of lipid extracts, cells, and Alzheimer's model mouse brain tissue.

Authors:  Kelly Dimovska Nilsson; Anthi Karagianni; Ibrahim Kaya; Marcus Henricsson; John S Fletcher
Journal:  Anal Bioanal Chem       Date:  2021-05-11       Impact factor: 4.142

Review 5.  Mass Spectrometry Imaging and Integration with Other Imaging Modalities for Greater Molecular Understanding of Biological Tissues.

Authors:  Tiffany Porta Siegel; Gregory Hamm; Josephine Bunch; Jo Cappell; John S Fletcher; Kristina Schwamborn
Journal:  Mol Imaging Biol       Date:  2018-12       Impact factor: 3.488

Review 6.  [Mass spectrometry imaging technology and its application in breast cancer research].

Authors:  Mengting Zhang; Yulu Zhang; Haojiang Wang; Ning Li; Bo Li; Hong Xiao; Wei Bian; Zongwei Cai
Journal:  Se Pu       Date:  2021-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.