Literature DB >> 26860914

Effect of Watermarking on Diagnostic Preservation of Atherosclerotic Ultrasound Video in Stroke Telemedicine.

Nilanjan Dey1,2,3, Soumyo Bose2, Achintya Das4, Sheli Sinha Chaudhuri1, Luca Saba5, Shoaib Shafique6, Andrew Nicolaides7,8, Jasjit S Suri9,10,11.   

Abstract

Embedding of diagnostic and health care information requires secure encryption and watermarking. This research paper presents a comprehensive study for the behavior of some well established watermarking algorithms in frequency domain for the preservation of stroke-based diagnostic parameters. Two different sets of watermarking algorithms namely: two correlation-based (binary logo hiding) and two singular value decomposition (SVD)-based (gray logo hiding) watermarking algorithms are used for embedding ownership logo. The diagnostic parameters in atherosclerotic plaque ultrasound video are namely: (a) bulb identification and recognition which consists of identifying the bulb edge points in far and near carotid walls; (b) carotid bulb diameter; and (c) carotid lumen thickness all along the carotid artery. The tested data set consists of carotid atherosclerotic movies taken under IRB protocol from University of Indiana Hospital, USA-AtheroPoint™ (Roseville, CA, USA) joint pilot study. ROC (receiver operating characteristic) analysis was performed on the bulb detection process that showed an accuracy and sensitivity of 100 % each, respectively. The diagnostic preservation (DPsystem) for SVD-based approach was above 99 % with PSNR (Peak signal-to-noise ratio) above 41, ensuring the retention of diagnostic parameter devalorization as an effect of watermarking. Thus, the fully automated proposed system proved to be an efficient method for watermarking the atherosclerotic ultrasound video for stroke application.

Entities:  

Keywords:  Atherosclerosis; Bulb detection; Bulb diameter; Carotid video; Operating characteristics; Peak signal-to-noise ratio; Stroke; Telemedicine; Watermarking

Mesh:

Year:  2016        PMID: 26860914     DOI: 10.1007/s10916-016-0451-3

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  36 in total

1.  Compact storage of medical images with patient information.

Authors:  R Acharya; D Anand; S Bhat; U C Niranjan
Journal:  IEEE Trans Inf Technol Biomed       Date:  2001-12

2.  Inter-greedy technique for fusion of different segmentation strategies leading to high-performance carotid IMT measurement in ultrasound images.

Authors:  Filippo Molinari; Guang Zeng; Jasjit S Suri
Journal:  J Med Syst       Date:  2010-05-08       Impact factor: 4.460

3.  The secure authorization model for healthcare information system.

Authors:  Wen-Shin Hsu; Jiann-I Pan
Journal:  J Med Syst       Date:  2013-09-06       Impact factor: 4.460

4.  Rapid automated classification of anesthetic depth levels using GPU based parallelization of neural networks.

Authors:  Musa Peker; Baha Şen; Hüseyin Gürüler
Journal:  J Med Syst       Date:  2015-02-04       Impact factor: 4.460

5.  Improved correlation between carotid and coronary atherosclerosis SYNTAX score using automated ultrasound carotid bulb plaque IMT measurement.

Authors:  Nobutaka Ikeda; Ajay Gupta; Nilanjan Dey; Soumyo Bose; Shoaib Shafique; Tadashi Arak; Elisa Cuadrado Godia; Luca Saba; John R Laird; Andrew Nicolaides; Jasjit S Suri
Journal:  Ultrasound Med Biol       Date:  2015-01-28       Impact factor: 2.998

6.  Lumen segmentation and stenosis quantification of atherosclerotic carotid arteries in CTA utilizing a centerline intensity prior.

Authors:  Hui Tang; Theo van Walsum; Reinhard Hameeteman; Rahil Shahzad; Lucas J van Vliet; Wiro J Niessen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

Review 7.  Ovarian tissue characterization in ultrasound: a review.

Authors:  U Rajendra Acharya; Filippo Molinari; S Vinitha Sree; G Swapna; Luca Saba; Stefano Guerriero; Jasjit S Suri
Journal:  Technol Cancer Res Treat       Date:  2014-09-16

8.  On the security of two remote user authentication schemes for telecare medical information systems.

Authors:  Kee-Won Kim; Jae-Dong Lee
Journal:  J Med Syst       Date:  2014-04-29       Impact factor: 4.460

9.  Hybrid Features and Mediods Classification based Robust Segmentation of Blood Vessels.

Authors:  Amna Waheed; M Usman Akram; Shehzad Khalid; Zahra Waheed; Muazzam A Khan; Arslan Shaukat
Journal:  J Med Syst       Date:  2015-08-26       Impact factor: 4.460

10.  A patient privacy protection scheme for medical information system.

Authors:  Chenglang Lu; Zongda Wu; Mingyong Liu; Wei Chen; Junfang Guo
Journal:  J Med Syst       Date:  2013-10-30       Impact factor: 4.460

View more
  1 in total

1.  Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

Authors:  Tadashi Araki; P Krishna Kumar; Harman S Suri; Nobutaka Ikeda; Ajay Gupta; Luca Saba; Jeny Rajan; Francesco Lavra; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-06-14       Impact factor: 4.460

  1 in total