Literature DB >> 26859357

A Comparison of Sequential Glaucoma Drainage Device Implantation Versus Cyclophotocoagulation Following Failure of a Primary Drainage Device.

Joshua D Levinson1, Annette L Giangiacomo, Allen D Beck, Paul B Pruett, Hillary M Superak, Michael J Lynn, Anastasios P Costarides.   

Abstract

PURPOSE: To compare sequential glaucoma drainage device (GDD) implantation with transscleral diode cyclophotocoagulation (CPC) following failure of a primary GDD.
MATERIALS AND METHODS: A retrospective review of all patients who underwent GDD implantation at a single institution over 10 years. Patients who required an additional GDD and/or CPC were analyzed. Success was defined as absence of loss of light perception, reoperation for glaucoma, and intraocular pressure (IOP) >21 or <6 at 2 consecutive visits after an initial 3-month period.
RESULTS: Thirty-two patients received sequential GDD. Twenty-one underwent CPC. Cohorts were statistically similar in regards to age, sex, race, and number of previous surgeries. Preoperatively, the GDD cohort had a lower IOP and better visual acuity. The mean length of follow-up was 37.9 months for the GDD group and 46.3 months for CPC. Both procedures significantly reduced IOP; however, CPC led to a greater reduction (P=0.0172). Survival analysis found the 5-year probability of surgical success to be 65.3% for sequential GDD and 58.0% for CPC (P=0.8678). No cases of phthisis occurred in either group. There were 2 cases of endophthalmitis (6.3%) in the GDD group, and none in the CPC group. In eyes without preexisting corneal edema, estimated corneal decompensation probability at 3 years was 31.6% for GDD and 6.7% for CPC (P=0.0828).
CONCLUSIONS: Sequential GDD and CPC are both effective at reducing IOP following the failure of a primary GDD. CPC after GDD failure warrants further investigation as it led to a greater reduction in IOP with fewer serious adverse events.

Entities:  

Mesh:

Year:  2017        PMID: 26859357      PMCID: PMC4977200          DOI: 10.1097/IJG.0000000000000370

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  21 in total

1.  Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma.

Authors:  A A Shah; D WuDunn; L B Cantor
Journal:  Am J Ophthalmol       Date:  2000-04       Impact factor: 5.258

2.  Diode laser transscleral cyclophotocoagulation as a primary surgical treatment for primary open-angle glaucoma.

Authors:  P R Egbert; S Fiadoyor; D L Budenz; P Dadzie; S Byrd
Journal:  Arch Ophthalmol       Date:  2001-03

3.  Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004.

Authors:  Pradeep Y Ramulu; Kevin J Corcoran; Suzanne L Corcoran; Alan L Robin
Journal:  Ophthalmology       Date:  2007-04-27       Impact factor: 12.079

4.  Intermediate term safety and efficacy of transscleral cyclophotocoagulation after tube shunt failure.

Authors:  Peter J Ness; Mahmoud A Khaimi; Robert M Feldman; Rania Tabet; Steven R Sarkisian; Gregory L Skuta; Alice Z Chuang; Kimberly A Mankiewicz
Journal:  J Glaucoma       Date:  2012-02       Impact factor: 2.503

5.  Transscleral diode laser cycloablation in patients with good vision.

Authors:  A P Rotchford; R Jayasawal; S Madhusudhan; S Ho; A J King; S A Vernon
Journal:  Br J Ophthalmol       Date:  2010-06-24       Impact factor: 4.638

6.  Efficacy and safety of contact transscleral diode laser cyclophotocoagulation for advanced glaucoma.

Authors:  T Schlote; M Derse; K Rassmann; T Nicaeus; K Dietz; H J Thiel
Journal:  J Glaucoma       Date:  2001-08       Impact factor: 2.503

7.  The Ahmed versus Baerveldt study: three-year treatment outcomes.

Authors:  Panos G Christakis; James C Tsai; Jeffrey W Kalenak; David Zurakowski; Louis B Cantor; Jeffrey A Kammer; Iqbal I K Ahmed
Journal:  Ophthalmology       Date:  2013-06-21       Impact factor: 12.079

8.  Outcomes of sequential tube shunts in complicated glaucoma.

Authors:  J K Burgoyne; D WuDunn; V Lakhani; L B Cantor
Journal:  Ophthalmology       Date:  2000-02       Impact factor: 12.079

9.  Diode laser transscleral cyclophotocoagulation as primary surgical treatment for medically uncontrolled chronic angle closure glaucoma: long-term clinical outcomes.

Authors:  Jimmy S M Lai; Clement C Y Tham; Jonathan C H Chan; Dennis S C Lam
Journal:  J Glaucoma       Date:  2005-04       Impact factor: 2.503

10.  Sequential glaucoma implants in refractory glaucoma.

Authors:  Aashish Anand; Celso Tello; Paul A Sidoti; Robert Ritch; Jeffrey M Liebmann
Journal:  Am J Ophthalmol       Date:  2009-10-17       Impact factor: 5.258

View more
  6 in total

Review 1.  [Revision surgery in episcleral glaucoma drainage devices].

Authors:  A Rosentreter; T S Dietlein
Journal:  Ophthalmologe       Date:  2016-11       Impact factor: 1.059

2.  Safety and Efficacy of Second Ahmed Valve Implant in Refractory Glaucoma.

Authors:  Chiara Posarelli; Mario Damiano Toro; Robert Rejdak; Tomasz Żarnowski; Dorota Pożarowska; Antonio Longo; Mario Miccoli; Marco Nardi; Michele Figus
Journal:  J Clin Med       Date:  2020-06-29       Impact factor: 4.241

Review 3.  Cyclodestructive Procedures in Glaucoma: A Review of Current and Emerging Options.

Authors:  Anna I Dastiridou; Andreas Katsanos; Philippe Denis; Brian A Francis; Dimitrios G Mikropoulos; Miguel A Teus; Anastasios-Georgios Konstas
Journal:  Adv Ther       Date:  2018-11-17       Impact factor: 3.845

4.  Surgical outcomes of Glaucoma associated with Axenfeld-Rieger syndrome.

Authors:  Emily M Zepeda; Kari Branham; Sayoko E Moroi; Brenda L Bohnsack
Journal:  BMC Ophthalmol       Date:  2020-05-01       Impact factor: 2.209

5.  Outcomes of the Second Aqueous Shunt Implant Versus Transscleral Cyclophotocoagulation Treatment Study: A Randomized Comparative Trial.

Authors:  Robert M Feldman; Alice Z Chuang; Steve L Mansberger; Angelo P Tanna; Lauren S Blieden; Nicholas P Bell; Ronald L Gross; Louis R Pasquale; David S Greenfield; Jeffrey M Liebmann; Robert N Weinreb
Journal:  J Glaucoma       Date:  2022-07-21       Impact factor: 2.290

6.  Surgical Outcomes of a Second Ahmed Glaucoma Valve Implantation in Asian Eyes with Refractory Glaucoma.

Authors:  Sze Chuan Ong; Maria Cecilia Aquino; Paul Chew; Victor Koh
Journal:  J Ophthalmol       Date:  2020-03-23       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.