3D transthoracic echocardiography to assess pulmonary valve morphology and annulus size in patients with Tetralogy of Fallot.

Khaled Hadeed1, Sébastien Hascoët2, Romain Amadieu2, Yves Dulac2, Sophie Breinig2, Alexandre Cazavet3, Fabio Cuttone3, Bertrand Léobon3, Philippe Acar2.   

Abstract

BACKGROUND: Accurate evaluation of the pulmonary valve (PV) is crucial before surgical repair of Tetralogy of Fallot (TOF). AIMS: To assess PV and pulmonary annulus (PA) morphology using three-dimensional (3D) transthoracic echocardiography (TTE) in infants referred for surgical repair of TOF. Also, to compare PA measurements obtained by 3D TTE with those from other imaging modalities, including two-dimensional (2D) TTE and computed tomography (CT), with reference to surgical measurements.
METHODS: 3D zoom mode was used to assess PV morphology. 2D TTE and CT PA diameters were compared to both vertical and horizontal diameters obtained from 3D datasets. Surgical PA diameters were measured using Hegar's dilators.
RESULTS: A total of 29 patients with TOF (median [range] age 6 [3-24] months) were included and all successfully underwent 2D and 3D TTE; 22 also underwent CT. The number of pulmonary leaflets could be visualized in 24 patients (82.8%), with complete concordance with surgical findings. Vertical diameter was significantly longer than horizontal diameter (P<0.001)-underlying PA eccentricity-and was more important in bicuspid than tricuspid valves. Correlations between 2D and 3D TTE diameters were good. Surgical diameter was better correlated with 2D and 3D diameters than with CT diameter. 3D minimum, 2D and CT diameters were significantly lower than surgical diameters, but 3D mean and maximum diameters were not.
CONCLUSION: 3D TTE is accurate to assess PV morphology and PA size in patients with TOF. 2D TTE and CT underestimate PA diameter with reference to surgical diameter, however 3D mean and maximum diameters did not differ significantly.
Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Anneau pulmonaire; Cardiac computed tomography; Pulmonary annulus; Pulmonary valve; Scanner cardiaque; Three-dimensional echocardiography; Two-dimensional echocardiography; Valve pulmonaire; Échocardiographie bidimensionnelle; Échocardiographie tridimensionnelle

Mesh:

Year:  2016        PMID: 26858141     DOI: 10.1016/j.acvd.2015.12.001

Source DB:  PubMed          Journal:  Arch Cardiovasc Dis        ISSN: 1875-2128            Impact factor:   2.340


  2 in total

1.  Echocardiographic assessment of the tricuspid and pulmonary valves: a practical guideline from the British Society of Echocardiography.

Authors:  Abbas Zaidi; David Oxborough; Daniel X Augustine; Radwa Bedair; Allan Harkness; Bushra Rana; Shaun Robinson; Luigi P Badano
Journal:  Echo Res Pract       Date:  2020-12

2.  Tetralogy of Fallot: T-shaped infundibulotomy for pulmonary valve-sparing procedure.

Authors:  Bertrand Leobon; Grégoire Cousin; Khaled Hadeed; Sophie Breinig; Xavier Alacoque; Lionel Berthomieu; Clément Karsenty
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-02-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.