INTRODUCTION: MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. METHODS: Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. RESULTS: The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. CONCLUSION: This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage.
INTRODUCTION: MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. METHODS: Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. RESULTS: The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. CONCLUSION: This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage.
Authors: Gaston R Vergara; Sathya Vijayakumar; Eugene G Kholmovski; Joshua J E Blauer; Mike A Guttman; Christopher Gloschat; Gene Payne; Kamal Vij; Nazem W Akoum; Marcos Daccarett; Christopher J McGann; Rob S Macleod; Nassir F Marrouche Journal: Heart Rhythm Date: 2010-10-27 Impact factor: 6.343
Authors: Timm Dickfeld; Ritsushi Kato; Menekem Zviman; Saman Nazarian; Jun Dong; Hiroshi Ashikaga; Albert C Lardo; Ronald D Berger; Hugh Calkins; Henry Halperin Journal: Heart Rhythm Date: 2006-11-01 Impact factor: 6.343
Authors: Peter Nordbeck; Wolfgang R Bauer; Florian Fidler; Marcus Warmuth; Karl-Heinz Hiller; Matthias Nahrendorf; Michelle Maxfield; Sabine Wurtz; Wolfgang Geistert; Jens Broscheit; Peter M Jakob; Oliver Ritter Journal: Circ Arrhythm Electrophysiol Date: 2009-03-06
Authors: Jason G Andrade; Marc Dubuc; Peter G Guerra; Evelyn Landry; Nicolas Coulombe; Hugues Leduc; Léna Rivard; Laurent Macle; Bernard Thibault; Mario Talajic; Denis Roy; Paul Khairy Journal: J Cardiovasc Electrophysiol Date: 2013-03-13
Authors: Srinivas R Dukkipati; Richard Mallozzi; Ehud J Schmidt; Godtfred Holmvang; Andre d'Avila; Renee Guhde; Robert D Darrow; Glenn Slavin; Maggie Fung; Zachary Malchano; Greg Kampa; Jeremy D Dando; Christina McPherson; Thomas K Foo; Jeremy N Ruskin; Charles L Dumoulin; Vivek Y Reddy Journal: Circulation Date: 2008-08-04 Impact factor: 29.690
Authors: Ravi Ranjan; Eugene G Kholmovski; Joshua Blauer; Sathya Vijayakumar; Nelly A Volland; Mohamed E Salama; Dennis L Parker; Rob MacLeod; Nassir F Marrouche Journal: Circ Arrhythm Electrophysiol Date: 2012-10-15
Authors: Ehud J Schmidt; Richard P Mallozzi; Aravinda Thiagalingam; Godtfred Holmvang; Andre d'Avila; Renee Guhde; Robert Darrow; Glenn S Slavin; Maggie M Fung; Jeremy Dando; Lori Foley; Charles L Dumoulin; Vivek Y Reddy Journal: Circ Arrhythm Electrophysiol Date: 2009-12
Authors: Kamran Ahrar; Judy U Ahrar; Sanaz Javadi; Li Pan; Denái R Milton; Christopher G Wood; Surena F Matin; R Jason Stafford Journal: Invest Radiol Date: 2013-06 Impact factor: 6.016
Authors: Ehud J Schmidt; Ronald D Watkins; Menekhem M Zviman; Michael A Guttman; Wei Wang; Henry A Halperin Journal: Circ Cardiovasc Imaging Date: 2016-10 Impact factor: 7.792
Authors: Ivan Zeljkovic; Sven Knecht; Nikola Pavlovic; Umut Celikyrut; Florian Spies; Sarah Burri; Dominik Mannhart; Loris Peterhans; Tobias Reichlin; Beat Schaer; Stefan Osswald; Christian Sticherling; Michael Kuhne Journal: Open Heart Date: 2019-04-20