Literature DB >> 26854528

Development of a small single-ring OpenPET prototype with a novel transformable architecture.

Hideaki Tashima1, Eiji Yoshida, Naoko Inadama, Fumihiko Nishikido, Yasunori Nakajima, Hidekatsu Wakizaka, Tetsuya Shinaji, Munetaka Nitta, Shoko Kinouchi, Mikio Suga, Hideaki Haneishi, Taku Inaniwa, Taiga Yamaya.   

Abstract

The single-ring OpenPET (SROP), for which the detector arrangement has a cylinder shape cut by two parallel planes at a slant angle to form an open space, is our original proposal for in-beam PET. In this study, we developed a small prototype of an axial-shift type SROP (AS-SROP) with a novel transformable architecture for a proof-of-concept. In the AS-SROP, detectors originally forming a cylindrical PET are axially shifted little by little. We designed the small AS-SROP prototype for 4-layer depth-of-interaction detectors arranged in a ring diameter of 250 mm. The prototype had two modes: open and closed. The open mode formed the SROP with the open space of 139 mm and the closed mode formed a conventional cylindrical PET. The detectors were simultaneously moved by a rotation handle allowing them to be transformed between the two modes. We evaluated the basic performance of the developed prototype and carried out in-beam imaging tests in the HIMAC using (11)C radioactive beam irradiation. As a result, we found the open mode enabled in-beam PET imaging at a slight cost of imaging performance; the spatial resolution and sensitivity were 2.6 mm and 5.1% for the open mode and 2.1 mm and 7.3% for the closed mode. We concluded that the AS-SROP can minimize the decrease of resolution and sensitivity, for example, by transforming into the closed mode immediately after the irradiation while maintaining the open space only for the in-beam PET measurement.

Mesh:

Substances:

Year:  2016        PMID: 26854528     DOI: 10.1088/0031-9155/61/4/1795

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study.

Authors:  Jun Zhang; Michelle I Knopp; Michael V Knopp
Journal:  Mol Imaging Biol       Date:  2019-06       Impact factor: 3.488

Review 2.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

3.  Roadmap toward the 10 ps time-of-flight PET challenge.

Authors:  Paul Lecoq; Christian Morel; John O Prior; Dimitris Visvikis; Stefan Gundacker; Etiennette Auffray; Peter Križan; Rosana Martinez Turtos; Dominique Thers; Edoardo Charbon; Joao Varela; Christophe de La Taille; Angelo Rivetti; Dominique Breton; Jean-François Pratte; Johan Nuyts; Suleman Surti; Stefaan Vandenberghe; Paul Marsden; Katia Parodi; Jose Maria Benlloch; Mathieu Benoit
Journal:  Phys Med Biol       Date:  2020-10-22       Impact factor: 3.609

4.  Novel On-line PET Imaging for Intra-Beam Range Verification and Delivery Optimization: A Simulation Feasibility Study.

Authors:  Yuncheng Zhong; Weiguo Lu; Mingli Chen; Zhenyu Xiong; Xinyi Cheng; Kun Hu; Yiping Shao
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-10-30

Review 5.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

6.  Visualisation of Range Shortening in Carbon Ion Beams and Washout of Positron Emitter: First-in-Human Report.

Authors:  Shintaro Shiba; Makoto Sakai; Masahiko Okamoto; Tatsuya Ohno
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

7.  Integrated treatment using intraperitoneal radioimmunotherapy and positron emission tomography-guided surgery with 64Cu-labeled cetuximab to treat early- and late-phase peritoneal dissemination in human gastrointestinal cancer xenografts.

Authors:  Yukie Yoshii; Mitsuyoshi Yoshimoto; Hiroki Matsumoto; Hideaki Tashima; Yuma Iwao; Hiroyuki Takuwa; Eiji Yoshida; Hidekatsu Wakizaka; Taiga Yamaya; Ming-Rong Zhang; Aya Sugyo; Sayaka Hanadate; Atsushi B Tsuji; Tatsuya Higashi
Journal:  Oncotarget       Date:  2018-06-22

8.  Integrated 64Cu therapy for the peritoneal dissemination of gastrointestinal cancer.

Authors:  Hiroaki Kurihara
Journal:  Oncotarget       Date:  2018-07-27

9.  Deep learning-guided joint attenuation and scatter correction in multitracer neuroimaging studies.

Authors:  Hossein Arabi; Karin Bortolin; Nathalie Ginovart; Valentina Garibotto; Habib Zaidi
Journal:  Hum Brain Mapp       Date:  2020-05-21       Impact factor: 5.038

10.  Immuno-OpenPET: a novel approach for early diagnosis and image-guided surgery for small resectable pancreatic cancer.

Authors:  Yukie Yoshii; Hideaki Tashima; Yuma Iwao; Eiji Yoshida; Hidekatsu Wakizaka; Go Akamatsu; Taiga Yamaya; Hiroki Matsumoto; Mitsuyoshi Yoshimoto; Chika Igarashi; Fukiko Hihara; Tomoko Tachibana; Ming-Rong Zhang; Kotaro Nagatsu; Aya Sugyo; Atsushi B Tsuji; Tatsuya Higashi
Journal:  Sci Rep       Date:  2020-03-10       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.