Literature DB >> 26849876

EFLM WG-Preanalytical phase opinion paper: local validation of blood collection tubes in clinical laboratories.

Giuseppe Lippi, Michael P Cornes, Kjell Grankvist, Mads Nybo, Ana-Maria Simundic.   

Abstract

The selection or procurement of blood collection devices in healthcare facilities is often an underestimated issue. This is probably due to different factors including the lack of knowledge of policymakers, hospital administrators and even laboratory managers about the importance of preanalytical quality and phlebotomy process, as well as to the absence of reliable guidelines or recommendations on how to precisely assess the quality of blood collection devices around the globe. With the awareness that a gap remains between manufacturers' and local validation of blood collection devices, the Working Group for Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has drafted a consensus document aimed to provide a set of essential requisites, technical criteria (e.g. presence of physical defects, malfunctioning, safety problems) and clinical issues for supporting laboratory professionals in organization blood collection tubes tenders and validating new devices before local routine implementation. The laboratory professionals should also make sure that the tenders accurately and strictly define the responsibilities for validation experiments and the potential consequences in the case the validation outcome shows that tubes due not fulfill the expectations.

Mesh:

Year:  2016        PMID: 26849876     DOI: 10.1515/cclm-2015-1274

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  10 in total

1.  Standardizing in vitro diagnostics tasks in clinical trials: a call for action.

Authors:  Giuseppe Lippi; Ana-Maria Simundic; Leocadio Rodriguez-Manas; Patrick Bossuyt; Giuseppe Banfi
Journal:  Ann Transl Med       Date:  2016-05

2.  Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing.

Authors:  Robert C Gosselin; Annette Bowyer; Emmanuel J Favaloro; Jill M Johnsen; Giuseppe Lippi; Richard A Marlar; Keith Neeves; Marian A Rollins-Raval
Journal:  J Thromb Haemost       Date:  2021-09-02       Impact factor: 16.036

3.  Abnormal gel flotation caused by contrast media during adrenal vein sampling.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Matteo Gelati; Antonella Bassi; Alberto Contro; Francesca Pizzolo; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2016-10-15       Impact factor: 2.313

4.  The alcohol used for cleansing the venipuncture site does not jeopardize blood and plasma alcohol measurement with head-space gas chromatography and an enzymatic assay.

Authors:  Giuseppe Lippi; Ana-Maria Simundic; Giacomo Musile; Elisa Danese; Gianluca Salvagno; Franco Tagliaro
Journal:  Biochem Med (Zagreb)       Date:  2017-06-15       Impact factor: 2.313

5.  Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Andre Valpassos Pacifici Guimaraes; Jose Abol Correa; Giuseppe Lippi
Journal:  J Med Biochem       Date:  2017-01-25       Impact factor: 3.402

6.  Novel Opportunities for Improving the Quality of Preanalytical Phase. A Glimpse to the Future?

Authors:  Giuseppe Lippi; Janne Cadamuro
Journal:  J Med Biochem       Date:  2017-10-28       Impact factor: 3.402

7.  Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube?

Authors:  Sanja Mandić; Dario Mandić; Iva Lukić; Tara Rolić; Vesna Horvat; Maja Lukić; Silvija Osvald; Vatroslav Šerić
Journal:  Biochem Med (Zagreb)       Date:  2020-10-15       Impact factor: 2.313

8.  The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

Authors:  Fatma Demet Arslan; Inanc Karakoyun; Banu Isbilen Basok; Merve Zeytinli Aksit; Anil Baysoy; Yasemin Kilic Ozturk; Yusuf Adnan Guclu; Can Duman
Journal:  Biochem Med (Zagreb)       Date:  2017-08-28       Impact factor: 2.313

9.  Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument.

Authors:  Davide Ferrari; Marta Strollo; Matteo Vidali; Andrea Motta; Marina Pontillo; Massimo Locatelli
Journal:  Acta Biomed       Date:  2020-03-19

10.  Methodological variations affect the release of VEGF in vitro and fibrinolysis' time from platelet concentrates.

Authors:  Leonel Alves de Oliveira; Tatiana Karla Borges; Renata Oliveira Soares; Marcelo Buzzi; Selma Aparecida Souza Kückelhaus
Journal:  PLoS One       Date:  2020-10-07       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.