Literature DB >> 26843744

Comparative clinical evaluation of removable partial dentures made of two different materials in Kennedy Applegate class II partially edentulous situation.

Maninder Hundal1, Rajesh Madan2.   

Abstract

BACKGROUND: Cast Chromium Cobalt alloy has been the material of choice for fabricating Removable Partial Dentures (RPDs) but has certain drawbacks. Newer materials like the flexible Nylon based Super Polyamide have been introduced to overcome these drawbacks. The present study has compared the above two materials for nine clinical parameters.
METHOD: The study was carried out on 30 patients presenting with a Kennedy Applegate class II partially edentulous situation who were divided into two equal groups and clinically assessed. RESULT: Statistically significant results were obtained in favor of flexible RPDs, in the parameters of 'aesthetics' and 'overall patient satisfaction'. Both groups showed more or less similar values for 'frequency of fracture of the prosthesis during usage' with the incidence being slightly higher for patients wearing the cast RPDs. The clinical parameters of 'oral soft tissue tolerance', 'gingival health', 'periodontal health' and 'adaptability in areas with undercut' were statistically at par for all the 30 patients thus suggesting the comparable biocompatibility of the two materials. The highlight of this study was the relative ease in fabrication of the flexible RPDs as compared to the cast RPDs.
CONCLUSION: Based on the favorable clinical results of this study, it can be summarized that the flexible RPDs is a viable alternative to cast RPDs in Kennedy Applegate class II partially edentulous situation in the short term.

Entities:  

Keywords:  Cast chromium cobalt alloy removable partial denture; Clinical comparison; Flexible removable partial denture; Kennedy Applegate class II partially edentulous situation

Year:  2012        PMID: 26843744      PMCID: PMC4705100          DOI: 10.1016/j.mjafi.2012.08.020

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  4 in total

1.  A modified direct retainer design for distal-extension removable partial dentures.

Authors:  Z Ben-Ur; I Aviv; H S Cardash
Journal:  J Prosthet Dent       Date:  1988-09       Impact factor: 3.426

2.  Clasp design for extension-base removable partial dentures.

Authors:  A J Krol
Journal:  J Prosthet Dent       Date:  1973-04       Impact factor: 3.426

3.  Making chromium-cobalt removable partial dentures: a modified technique.

Authors:  B R Lanier; K D Rudd; R R Strunk
Journal:  J Prosthet Dent       Date:  1971-02       Impact factor: 3.426

4.  RPA clasp design for distal-extension removable partial dentures.

Authors:  C M Eliason
Journal:  J Prosthet Dent       Date:  1983-01       Impact factor: 3.426

  4 in total
  4 in total

1.  Denture cleanliness and hygiene: an overview.

Authors:  Petros Mylonas; Paul Milward; Robert McAndrew
Journal:  Br Dent J       Date:  2022-07-08       Impact factor: 2.727

Review 2.  Final-impression techniques and materials for making complete and removable partial dentures.

Authors:  Srinivasan Jayaraman; Balendra P Singh; Balasubramanian Ramanathan; Murukan Pazhaniappan Pillai; Laura MacDonald; Richard Kirubakaran
Journal:  Cochrane Database Syst Rev       Date:  2018-04-04

3.  An innovative sectional silicone obturator in a patient with partial maxillectomy: A Case report.

Authors:  Thirumurthy V Ramasamy; Jagadish Chandra
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27

4.  Impact of Removable Partial Denture Type on Patient Satisfaction and Abutment Survival Rate-RCT.

Authors:  Sherif A Sadek; Dina Elawady
Journal:  Open Access Maced J Med Sci       Date:  2019-08-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.