Literature DB >> 26837086

Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test.

Lynn Fielitz1, Jeffrey Coelho1, Thomas Horne1, William Brechue1.   

Abstract

The purpose of this study was to assess inter-rater reliability and intra-rater reliability of the 2-minute, 90° push-up test as utilized in the Army Physical Fitness Test. Analysis of rater assessment reliability included both total score agreement and agreement across individual push-up repetitions. This study utilized 8 Raters who assessed 15 different videotaped push-up performances over 4 iterations separated by a minimum of 1 week. The 15 push-up participants were videotaped during the semiannual Army Physical Fitness Test. Each Rater randomly viewed the 15 push-up and verbally responded with a "yes" or "no" to each push-up repetition. The data generated were analyzed using the Pearson product-moment correlation as well as the kappa, modified kappa and the intra-class correlation coefficient (3,1). An attribute agreement analysis was conducted to determine the percent of inter-rater and intra-rater agreement across individual push-ups.The results indicated that Raters varied a great deal in assessing push-ups. Over the 4 trials of 15 participants, the overall scores of the Raters varied between 3.0 and 35.7 push-ups. Post hoc comparisons found that there was significant increase in the grand mean of push-ups from trials 1-3 to trial 4 (p < 0.05). Also, there was a significant difference among raters over the 4 trials (p < 0.05). Pearson correlation coefficients for inter-rater and intra-rater reliability identified inter-rater reliability coefficients were between 0.10 and 0.97. Intra-rater coefficients were between 0.48 and 0.99. Intra-rater agreement for individual push-up repetitions ranged from 41.8% to 84.8%. The results indicated that the raters failed to assess the same push-up repetition with the same score (below 70% agreement) as well as failed to agree when viewed between raters (29%). Interestingly, as previously mentioned, scores on trial 4 increased significantly which might have been caused by rater drift or that the Raters did not maintain the push-up standard over the trials. It does appear that the final push-up scores received by each participant was a close approximation of actual performance (within 65%) but when assessing physical performance for retention in the Army, a more reliable test might be considered. Reprint &
Copyright © 2016 Association of Military Surgeons of the U.S.

Entities:  

Mesh:

Year:  2016        PMID: 26837086     DOI: 10.7205/MILMED-D-14-00533

Source DB:  PubMed          Journal:  Mil Med        ISSN: 0026-4075            Impact factor:   1.437


  4 in total

1.  REPEATABILITY OF SWAY MEASURES IN UPPER EXTREMITY WEIGHT-BEARING.

Authors:  Marisa Pontillo; Brian Sennett
Journal:  Int J Sports Phys Ther       Date:  2020-10

2.  Development of a Standard Push-up Scale for College-Aged Females.

Authors:  Melanie M Adams; Sophie A Hatch; Elizabeth G Winsor; Caitlyn Parmelee
Journal:  Int J Exerc Sci       Date:  2022-06-01

3.  A Bilateral Comparison of the Underlying Mechanics Contributing to the Seated Single-Arm Shot-Put Functional Performance Test.

Authors:  Bryan L Riemann; Wayne Johnson; Thomas Murphy; George J Davies
Journal:  J Athl Train       Date:  2018-10-09       Impact factor: 2.860

4.  Reliability of Field-Based Fitness Tests in Adults: A Systematic Review.

Authors:  Magdalena Cuenca-Garcia; Nuria Marin-Jimenez; Alejandro Perez-Bey; David Sánchez-Oliva; Daniel Camiletti-Moiron; Inmaculada C Alvarez-Gallardo; Francisco B Ortega; Jose Castro-Piñero
Journal:  Sports Med       Date:  2022-01-22       Impact factor: 11.928

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.