Literature DB >> 26834505

Rapid scan electron paramagnetic resonance at 1.0 GHz of defect centers in γ-irradiated organic solids.

Yilin Shi1, George A Rinard2, Richard W Quine2, Sandra S Eaton1, Gareth R Eaton1.   

Abstract

The radicals in six 60Co γ-irradiated solids: malonic acid, glycylglycine, 2,6 di-t-butyl 4-methyl phenol, L-alanine, dimethyl malonic acid, and 2-amino isobutyric acid, were studied by rapid scan electron paramagnetic resonance at L-band (1.04 GHz) using a customized Bruker Elexsys spectrometer and a locally-designed dielectric resonator. Sinusoidal scans with widths up to 18.2 mT were generated with the recently described coil driver and Litz wire coils. Power saturation curves showed that the rapid scan signals saturated at higher powers than did conventional continuous wave signals. The rapid scan data were deconvolved and background subtracted to obtain absorption spectra. For the same data acquisition time the signal-to-noise for the absorption spectra obtained in rapid scans were 23 to 37 times higher than for first-derivative spectra obtained by conventional continuous wave electron paramagnetic resonance.

Entities:  

Keywords:  60Co γ-irradiated solids; L-band; electron paramagnetic resonance; rapid scan; signal-to-noise

Year:  2016        PMID: 26834505      PMCID: PMC4731870          DOI: 10.1016/j.radmeas.2015.12.011

Source DB:  PubMed          Journal:  Radiat Meas        ISSN: 1350-4487            Impact factor:   1.898


  22 in total

1.  Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry.

Authors:  Felipe Chen; Carlos F O Graeff; Oswaldo Baffa
Journal:  Phys Med Biol       Date:  2002-04-21       Impact factor: 3.609

2.  X-band rapid-scan EPR of nitroxyl radicals.

Authors:  Deborah G Mitchell; Richard W Quine; Mark Tseitlin; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-11-20       Impact factor: 2.229

Review 3.  EPR dosimetry with tooth enamel: A review.

Authors:  Paola Fattibene; Freddy Callens
Journal:  Appl Radiat Isot       Date:  2010-06-04       Impact factor: 1.513

4.  Comparison of Continuous Wave, Spin Echo, and Rapid Scan EPR of Irradiated Fused Quartz.

Authors:  Deborah G Mitchell; Richard W Quine; Mark Tseitlin; Virginia Meyer; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Meas       Date:  2011-09       Impact factor: 1.898

5.  Multifrequency electron paramagnetic resonance of irradiated L-alanine.

Authors:  B T Ghim; J L Du; S Pfenninger; G A Rinard; R W Quine; S S Eaton; G R Eaton
Journal:  Appl Radiat Isot       Date:  1996 Nov-Dec       Impact factor: 1.513

6.  Quantitative rapid scan EPR spectroscopy at 258 MHz.

Authors:  Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2010-03-21       Impact factor: 2.229

7.  Uncertainty analysis for absorption and first-derivative EPR spectra.

Authors:  Mark Tseitlin; Sandra S Eaton; Gareth R Eaton
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2012-11       Impact factor: 0.481

8.  Improved sensitivity for imaging spin trapped hydroxyl radical at 250 MHz.

Authors:  Joshua R Biller; Mark Tseitlin; Deborah G Mitchell; Zhelin Yu; Laura A Buchanan; Hanan Elajaili; Gerald M Rosen; Joseph P Y Kao; Sandra S Eaton; Gareth R Eaton
Journal:  Chemphyschem       Date:  2014-12-08       Impact factor: 3.102

9.  Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans.

Authors:  Mark Tseitlin; Deborah G Mitchell; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2012-08-08       Impact factor: 2.229

10.  Room temperature radiation products in trehalose single crystals: EMR and DFT analysis.

Authors:  Hendrik De Cooman; Mihaela Adeluta Tarpan; Henk Vrielinck; Michel Waroquier; Freddy Callens
Journal:  Radiat Res       Date:  2013-02-01       Impact factor: 2.841

View more
  3 in total

1.  UHF EPR spectrometer operating at frequencies between 400 MHz and 1 GHz.

Authors:  Richard W Quine; George A Rinard; Yilin Shi; Laura Buchanan; Joshua R Biller; Sandra S Eaton; Gareth R Eaton
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-07       Impact factor: 1.176

2.  Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails.

Authors:  Hanan Elajaili; Joseph McPeak; Alexander Romanyukha; Priyanka Aggarwal; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Prot Dosimetry       Date:  2016-09-02       Impact factor: 0.972

Review 3.  Rapid-scan EPR imaging.

Authors:  Sandra S Eaton; Yilin Shi; Lukas Woodcock; Laura A Buchanan; Joseph McPeak; Richard W Quine; George A Rinard; Boris Epel; Howard J Halpern; Gareth R Eaton
Journal:  J Magn Reson       Date:  2017-07       Impact factor: 2.229

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.