Literature DB >> 26833218

Transverse Compression of Tendons.

S T Samuel Salisbury, C Paul Buckley, Amy B Zavatsky.   

Abstract

A study was made of the deformation of tendons when compressed transverse to the fiber-aligned axis. Bovine digital extensor tendons were compression tested between flat rigid plates. The methods included: in situ image-based measurement of tendon cross-sectional shapes, after preconditioning but immediately prior to testing; multiple constant-load creep/recovery tests applied to each tendon at increasing loads; and measurements of the resulting tendon displacements in both transverse directions. In these tests, friction resisted axial stretch of the tendon during compression, giving approximately plane-strain conditions. This, together with the assumption of a form of anisotropic hyperelastic constitutive model proposed previously for tendon, justified modeling the isochronal response of tendon as that of an isotropic, slightly compressible, neo-Hookean solid. Inverse analysis, using finite-element (FE) simulations of the experiments and 10 s isochronal creep displacement data, gave values for Young's modulus and Poisson's ratio of this solid of 0.31 MPa and 0.49, respectively, for an idealized tendon shape and averaged data for all the tendons and E = 0.14 and 0.10 MPa for two specific tendons using their actual measured geometry. The compression load versus displacement curves, as measured and as simulated, showed varying degrees of stiffening with increasing load. This can be attributed mostly to geometrical changes in tendon cross section under load, varying according to the initial 3D shape of the tendon.

Entities:  

Mesh:

Year:  2016        PMID: 26833218     DOI: 10.1115/1.4032627

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Fatigue loading of tendon results in collagen kinking and denaturation but does not change local tissue mechanics.

Authors:  Spencer E Szczesny; Céline Aeppli; Alexander David; Robert L Mauck
Journal:  J Biomech       Date:  2018-02-21       Impact factor: 2.712

2.  Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling.

Authors:  Babak N Safa; Ellen T Bloom; Andrea H Lee; Michael H Santare; Dawn M Elliott
Journal:  J Biomech       Date:  2020-06-26       Impact factor: 2.712

3.  Identifiability of tissue material parameters from uniaxial tests using multi-start optimization.

Authors:  Babak N Safa; Michael H Santare; C Ross Ethier; Dawn M Elliott
Journal:  Acta Biomater       Date:  2021-01-11       Impact factor: 8.947

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.