Literature DB >> 26830079

Fully validated LCMS bioanalysis of Bevacizumab in human plasma using nano-surface and molecular-orientation limited (nSMOL) proteolysis.

Noriko Iwamoto1, Yukari Umino1, Chikage Aoki1, Naoe Yamane2, Akinobu Hamada3, Takashi Shimada4.   

Abstract

The chemistry of nano-surface and molecular-orientation limited (nSMOL) proteolysis is the Fab-selective limited proteolysis by making use the difference of protease nanoparticle diameter (200 nm) and antibody resin pore diameter (100 nm). In this report, we have demonstrated that the full validation for Bevacizumab bioanalysis in human plasma using nSMOL. The immunoglobulin fraction was collected by Protein A resin from plasma, then nSMOL reaction was performed using the FG nanoparticle-immobilized trypsin under the nondenaturing physiological condition at 50 °C for 6 h. After removal of resin and nanoparticles, the signature peptide of Bevacizumab complementarity-determining region (CDR) and internal standard P14R were simultaneously quantified by LCMS multiple reaction monitoring (MRM). This nSMOL method quantification of Bevacizumab showed sensitivity of 0.146 μg/ml and linearity of 0.146-300 μg/ml. The intra- and inter-assay precision of lower limit of quantification (LLOQ), low quality control (LQC), middle quality control (MQC), and high quality control (HQC) was 7.94-15.2% and 14.6%, 7.15-13.5% and 11.7%, 2.63-6.47% and 5.83%, and 3.09-4.35% and 4.45%, respectively. These results indicate that nSMOL is also significant method for Bevacizumab bioanalysis in human plasma.
Copyright © 2015 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Antibody drugs; Bioanalysis; Clinical pharmacokinetics; LCMS; nSMOL

Mesh:

Substances:

Year:  2015        PMID: 26830079     DOI: 10.1016/j.dmpk.2015.11.004

Source DB:  PubMed          Journal:  Drug Metab Pharmacokinet        ISSN: 1347-4367            Impact factor:   3.614


  6 in total

1.  Direct and Precise Measurement of Bevacizumab Levels in Human Plasma Based on Controlled Methionine Oxidation and Multiple Reaction Monitoring.

Authors:  Vanessa P Gaspar; Sahar Ibrahim; Constance A Sobsey; Vincent R Richard; Alan Spatz; René P Zahedi; Christoph H Borchers
Journal:  ACS Pharmacol Transl Sci       Date:  2020-11-13

2.  Comparison of Bevacizumab Quantification Results in Plasma of Non-small Cell Lung Cancer Patients Using Bioanalytical Techniques Between LC-MS/MS, ELISA, and Microfluidic-based Immunoassay.

Authors:  Noriko Iwamoto; Megumi Takanashi; Takashi Shimada; Jiichiro Sasaki; Akinobu Hamada
Journal:  AAPS J       Date:  2019-08-20       Impact factor: 4.009

3.  Microvolume Analysis of Aflibercept in Aqueous Humor Using Mass Spectrometry.

Authors:  Natsuka Kimura; Hidenori Takahashi; Shinichi Sakamoto; Yasuo Yanagi; Nozomi Maeshima; Ayaka Minamimoto; Noriko Iwamoto; Takashi Shimada; Ryozo Nagai; Kenichi Aizawa
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

4.  Application of nSMOL coupled with LC-MS bioanalysis for monitoring the Fc-fusion biopharmaceuticals Etanercept and Abatacept in human serum.

Authors:  Noriko Iwamoto; Kotoko Yokoyama; Megumi Takanashi; Atsushi Yonezawa; Kazuo Matsubara; Takashi Shimada
Journal:  Pharmacol Res Perspect       Date:  2018-07-24

Review 5.  Utility, promise, and limitations of liquid chromatography-mass spectrometry-based therapeutic drug monitoring in precision medicine.

Authors:  Vanessa P Gaspar; Sahar Ibrahim; René P Zahedi; Christoph H Borchers
Journal:  J Mass Spectrom       Date:  2021-11-04       Impact factor: 1.982

6.  Verification between Original and Biosimilar Therapeutic Antibody Infliximab Using nSMOL Coupled LC-MS Bioanalysis in Human Serum.

Authors:  Noriko Iwamoto; Kotoko Yokoyama; Megumi Takanashi; Atsushi Yonezawa; Kazuo Matsubara; Takashi Shimada
Journal:  Curr Pharm Biotechnol       Date:  2018       Impact factor: 2.837

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.