| Literature DB >> 26823991 |
Ramakrishna R Voggu1, Xiang Zhou1, Bin Su1, Baochuan Guo1.
Abstract
BMCL26 is a potential drug derived from nimesulide, which has exhibited the substantial anti-parasitic activity in various cell lines. To conduct various pharmacological and toxicological properties of this drug, we developed and validated a rapid LC-MS/MS method for its quantification in accordance with the FDA guidelines. Protein precipitation with 0.1% formic acid in acetonitrile was used to extract the analytes along with the internal standard (JCC76) from rat plasma. It was found that the calibration curve of the method had an excellent linearity (r2 ≥ 0.9993) for the analyte concentration ranging from 0.5 to 100 ng/mL with acceptable inter- and intra-assay, precision, accuracy and stability. The matrix effect and extraction recovery were in the range of 101.30-110.10% and 90.16- 105.00%, respectively. This LC-MS/MS method is simple and rapid and can be used in the future pharmaceutical studies of BMCL26.Entities:
Keywords: Anti-parasitic; BMCL26; LC-MS/MS; Protein precipitation; Rat plasma
Year: 2015 PMID: 26823991 PMCID: PMC4727756 DOI: 10.4172/2155-9872.1000266
Source DB: PubMed Journal: J Anal Bioanal Tech
Figure 1The chemical structures of JCC76 (A), internal standard BMCL26 (B).
HPLC gradient program.
| Minutes | Event | Parameters |
|---|---|---|
| 0–0.6 | B% | 70 (isocratic) |
| 0.6–1.6 | B% | 70–90 (liner) |
| 0–3.5 | Total flow | 0.25 ml/min |
| 3.5–3.7 | Total flow | 0.25–0.6 ml/min |
| 1.6–5.5 | B% | 90 (isocratic) |
| 5.5–5.6 | B% | 90–70 (liner) |
| 3.5–5.9 | Total flow | 0.6 ml/min |
| 5.9–6.0 | Total flow | 0.25–0.6 ml/min |
| 5.6–7.5 | B% | 70 (liner) |
Figure 2Precursor/product ion spectra and proposed fragmentation pathways for internal standard JCC76 (A) and analyte BMCL26 (B).
Figure 3(A) MRM chromatograms of blank rat plasma in both IS and Analyte windows (B) IS JCC76 (10 ng/ml, 3.12 min) and BMCL26 at LLOQ level (0.5 ng/ml, 2.48 min).
Accuracy and precision of BMCL26 calibration standards in rat plasma (n=5, pooled plasma samples).
| Nominal Concentration (ng/mL) | Determined Concentration (ng/mL) | Accuracy (%RE) | Precision (%CV) |
|---|---|---|---|
| 0.5 | 0.47 ± 0.03 | −7.46 | 5.59 |
| 1 | 0.99 ± 0.02 | −0.22 | 2.09 |
| 2.5 | 2.54 ± 0.05 | 1.40 | 2.01 |
| 5 | 5.14 ± 0.27 | 2.80 | 5.24 |
| 12.5 | 12.75 ± 0.31 | 2.00 | 2.41 |
| 25 | 25.27 ± 0.73 | 1.08 | 2.90 |
| 50 | 51.03 ± 0.97 | 2.06 | 1.90 |
| 100 | 98.26 ± 0.99 | −1.74 | 1.01 |
Inter and intra-assay accuracy and precision of BMCL26 in rat plasma.
| Intra-assay | Inter-assay | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Normal (ng/ml) | Determined (ng/ml) | Accuracy (%RE) | SD | Precision (%CV) | Determined (ng/ml) | Accuracy (%RE) | SD | Precision (%CV) | ||
| 1.25 | 1.20 | 11.36 | 0.02 | 1.72 | 1.36 | 9.12 | 0.04 | 3.38 | ||
| 10 | 10.20 | 2.00 | 0.16 | 1.64 | 10.20 | 2.00 | 0.35 | 3.43 | ||
| 80 | 80.70 | 0.87 | 0.68 | 0.84 | 80.50 | 0.62 | 2.80 | 3.47 | ||
Absolute and relative Extraction recovery of BMCL26 in rat plasma.
| Concentration of QC samples(ng/ml) | Absolute | Relative | ||
|---|---|---|---|---|
| 1.25 | ||||
| 104.00 ± 4.89 | 4.70 | 98.10 ± 9.73 | 9.92 | |
| 10 | 105.00 ± 4.99 | 4.75 | 95.96 ± 3.61 | 3.76 |
| 80 | 96.30 ± 3.00 | 3.12 | 90.16 ± 2.87 | 3.18 |
Absolute and relative matrix effect of BMCL26 in rat plasma.
| Concentration of QC samples(ng/ml) | Absolute | Relative | ||
|---|---|---|---|---|
| 1.25 | ||||
| 105.00 ± 1.07 | 1.02 | 108.00 ± 5.15 | 4.77 | |
| 10 | 107.00 ± 6.06 | 5.66 | 110.10 ± 8.99 | 8.17 |
| 80 | 105.00 ± 3.86 | 3.68 | 101.30 ± 4.78 | 4.72 |
Stability of BMCL26 in plasma samples.
| Storage conditions | Concentration (ng/ml) | Recovery % |
|---|---|---|
| Bench top (8 hr) | 1.25 | 103.46 |
| At room temp | 80.00 | 103.20 |
| Freeze thaw (3 cycles) | 1.25 | 98.13 |
| 80.00 | 105.20 | |
| Post extraction | 1.25 | 101.86 |
| (10 hr) at room temp | 80.00 | 107.54 |