Agreement between inferior vena cava diameter measurements by subxiphoid versus transhepatic views.

Atul Prabhakar Kulkarni1, S Janarthanan1, M M Harish1, Siddique Suhail1, Harish Chaudhari1, Vandana Agarwal2, Vijaya P Patil2, Jigeeshu V Divatia2.   

Abstract

CONTEXT: Correcting hypovolemia is extremely important. Central venous pressure measurement is often done to assess volume status. Measurement of inferior vena cava (IVC) is conventionally done in the subcostal view using ultrasonography. It may not be possible to obtain this view in all patients. AIMS: We therefore evaluated the limits of agreement between the IVC diameter measurement and variation in subcostal and that by the lateral transhepatic view. SETTINGS AND
DESIGN: Prospective study in a tertiary care referral hospital intensive care unit. SUBJECTS AND METHODS: After Institutional Ethics Committee approval and informed consent, we obtained 175 paired measurements of the IVC diameter and variation in both the views in adult mechanically ventilated patients. The measurements were carried out by experienced researchers. We then obtained the limits of agreement for minimum, maximum diameter, percentage variation of IVC in relation to respiration. STATISTICAL ANALYSIS USED: Bland-Altman's limits of agreement to get precision and bias.
RESULTS: The limits of agreement were wide for minimum and maximum IVC diameter with variation of as much as 4 mm in both directions. However, the limits of agreement were much narrower when the percentage variation in relation to respiration was plotted on the Bland-Altman plot.
CONCLUSIONS: We conclude that when it is not possible to obtain the subcostal view, it is possible to use the lateral transhepatic view. However, using the percentage variation in IVC size is likely to be more reliable than the absolute diameter alone. It is possible to use both views interchangeably.

Entities:  

Keywords:  Fluid responsiveness; inferior vena cava collapsibility; inferior vena cava diameter; inferior vena cava distensibility; limits of agreement

Year:  2015        PMID: 26816446      PMCID: PMC4711204          DOI: 10.4103/0972-5229.171390

Source DB:  PubMed          Journal:  Indian J Crit Care Med        ISSN: 0972-5229


Introduction

Hypovolemia is frequent in critically ill patients and may result in inadequate tissue perfusion and subsequent multi-organ failure. The estimation of intravascular volume status as well as fluid responsiveness is hence an important issue. Fluid replacement is an important intervention in these patients; however, excessive fluid infusion and an increase in net positive fluid balance lead to need for prolonged mechanical ventilation and increased mortality.[12] Therefore, it is essential to provide adequate fluid resuscitation without “overloading” in order to improve the outcome of the critically ill patients. This requires a careful assessment of the intravascular volume status and fluid responsiveness prior to the institution of fluid therapy. A variety of static and dynamic parameters have been used to assess fluid responsiveness. Over the last few years, bedside ultrasound (BUS) is being increasingly used by the intensivists to assess the intravascular volume status and fluid responsiveness by measuring inferior vena cava (IVC) diameter and variation in IVC diameter in relation to respiration.[3] In spontaneously breathing patients, the IVC diameter reduces during inspiration, whereas with positive pressure ventilation, the IVC diameter increases during inspiration, enabling calculation of indices such as dIVC, collapsibility, and distensibility index.[4] The actual IVC diameter measured on M-mode is correlated with the right atrial pressure. However, the variation in the size of the IVC, i.e. dIVC, collapsibility, and distensibility index, can be used to assess fluid responsiveness. The conventional view used to measure IVC diameter and variation in size is the subxiphoid view. Obtaining this view may be difficult in obese patients and those who have undergone abdominal surgery. We wanted to see if the transhepatic view of IVC can be an alternative to the subxiphoid view. The result of the study will add one more echocardiographic view to our armamentarium, and we will still be able to assess intravascular volume status even when the traditional subxiphoid view is not obtainable. We therefore evaluated the agreement between the measurement of IVC diameters and collapsibility/distensibility indices by the subcostal view and a lateral transhepatic view.

Subjects and Methods

This single center study was conducted prospectively in mechanically ventilated adult critically ill patients at a tertiary referral center. Hospital Ethics Committee approval was obtained for either deferred consent or for a consent from a surrogate. After informed consent, we included 88 patients in shock of any origin and in whom need for fluid infusion was anticipated and both subcostal and transhepatic views were obtainable. We excluded patients in whom either of the views was not possible for any reason or who did not give informed consent. For obtaining the subcostal view, patients were placed in supine position and the four-chamber view was obtained using a cardiac probe of the Sonosite™ (M-Turbo model) ultrasonography (USG) machine. Then by rotating and swinging the BUS probe to the right, the IVC was visualized and the diameter measured at the point of entry of the hepatic vein into the IVC. For the lateral transhepatic view, we used liver as an acoustic window, by placing the probe in the right anterior mid-axillary line, similar to the placement for evaluating Morison's pouch, in the Focused Assessment with Sonography for Trauma examination. The marker on probe pointed toward the head of the patient. By scanning more anteriorly and cephalad than the Morison's pouch view, the IVC was visualized running longitudinally adjacent to the liver and crossing the diaphragm. Again, the measurement of diameter was done at the entry of hepatic vein in IVC. The IVC collapsibility index during spontaneous breathing was expressed as the difference between the value of the maximum diameter and the minimum diameter, divided by the maximum of the two values. dIVC or ΔIVC was quantified by measuring the difference between the maximum and minimum diameters on the M-mode tracing and dividing it by the mean of the two. The denominator here is the mean diameter. The IVC distensibility index was measured during controlled mechanical ventilation and expressed as the difference between the value of the maximum diameter and the minimum diameter, divided by the minimum of the two values.[567] We obtained 175 paired measurements, two sets in one patient being obtained by two researchers at the same time. The researchers had been trained at a 2 days workshop on transthoracic echocardiography and subsequently had more than 2 years’ experience in BUS. In these 2 years, they had performed more than 100 bedside transthoracic echocardiography procedures each. They were blinded to the measurements made by each other, and later we took mean of both readings.

Statistics

Bland–Altman analysis was performed to determine the precision, bias, and limits of agreement between two methods of IVC diameter measurement. These were determined for the minimum and maximum IVC diameter as well as the variability in IVC diameter with respiration.

Results

In this prospective study, a total of 175 paired readings were obtained by two researchers blinded to each other's findings. The average of the values obtained by both observers was calculated. Limits of agreement were assessed separately for maximum diameter, minimum diameter, and variability. The limits of agreement were wide when both the minimum diameter and maximum diameter were plotted on the Bland–Altman graph [Figures 1 and 2]. For minimum diameter measured, the bias was 0.17 and the limits of agreement were 0.4 and −0.37. For maximum diameter, the bias was 0.027 and the limits of agreement were 0.4 and −0.36. For the percentage variability of the IVC diameter, the bias was 0.005 and the limits of agreement were 0.17 and −0.16 [Figure 3]. These limits of agreement were much narrower when compared with the maximum and minimum values of the IVC diameter.
Figure 1

Limits of agreement for average minimum IVC diameter

Figure 2

Limits of agreement for average maximum IVC diameter

Figure 3

Limits of agreement for average for variability in IVC diameter

Limits of agreement for average minimum IVC diameter Limits of agreement for average maximum IVC diameter Limits of agreement for average for variability in IVC diameter

Discussion

The minimum and maximum IVC diameter measured at two different sites differed by nearly by 4 mm on either side of the bias. The limits of agreement were narrower when the variation in size with respiration was taken into account. Hence, even if actual diameter value is not very useful, a change in diameter with respiration can be substituted when it is not possible to obtain either view. In the past years, many clinical and experimental studies led to the validation in mechanically ventilated patients of a few “dynamic” parameters based on heart-lung interactions. Assessing IVC diameter has been one of the methods to identify patients who are fluid responsive. A significant dilation of the IVC during tidal ventilation accurately predicts fluid responsiveness.[56] The IVC is a highly collapsible major vein, and its diameter closely correlates with right side cardiac function.[8] The IVC diameter has not been found to be affected by body's compensatory vasoconstrictor response to volume loss.[9] Hence, it reflects volume status more closely than other hemodynamic parameters such as blood pressure, pulse rate, diameter of aorta, and others. Studies in the past have shown the usefulness of IVC diameter in monitoring volume status in patients undergoing hemodialysis and in patients under mechanical ventilation in Intensive Care Units (ICUs).[10] To determine the status of intravascular volume, the dIVC measurement is one of the methods.[11] Yanagawa et al. used the dIVC expiratory (dIVCe) in the early diagnosis of hypovolemic shock using USG in patients with trauma.[12] In this study, the threshold level of the dIVCe for the diagnosis of hemorrhagic shock was 9 mm. The dIVCe (7.7 ± 0.3 mm) measured in the shock group was significantly lower than the level (13.4 ± 0.7 mm) measured in the control group. A similar study was performed by Sefidbakht et al. in patients with trauma.[13] In this study, dIVCe and dIVCi levels (5.6 ± 0.8 and 4 ± 0.7 mm) of the shock group were also significantly lower than those of the control group (11.9 ± 2.2 and 9.6 ± 2 mm), and the caval index (CI) was higher. These studies suggest the dIVC can be considered a reliable indicator of shock, although blood pressure is within normal limits because of sympathetic activation. Akilli et al. compared the dIVC with other shock parameters such as heart rate, systolic blood pressure/diastolic blood pressure, shock index, urine output, hemoglobin level, leukocyte count, and lactate and base excess in the patients admitted to the emergency department with hemorrhagic shock. They concluded that the dIVC in hemorrhagic shock was more valuable than in conventional shock parameters.[14] Schefold et al. studied IVC diameter correlation with invasive hemodynamic measures in mechanically ventilated ICU patients with sepsis.[15] IVC diameters were found to correlate with central venous pressure (CVP), extravascular lung water index, intrathoracic blood volume index, the intrathoracic thermal volume, and the PaO2/FiO2 oxygenation index. Therefore, sonographic determination of IVC diameter seems useful in the early assessment of fluid status in mechanically ventilated septic patients. Though IVC diameter variability can be used for fluid responsiveness, there are difficulties in assessing it in obese patients, in patients who had undergone abdominal surgeries and in whom IVC is difficult to visualize by standard subcostal view. The transhepatic view provides an alternative for this by assessing the IVC using liver as the acoustic window. We found wide limits of agreement when we plotted the minimum and max diameter. This difference could be due to the interrater variability and difference in angle of viewing. Fields et al. reported that the intraclass correlation coefficient of the IVC was 0.81 (95% CI, 0.67–0.89) for maximum IVC diameter and intraclass correlation coefficient was 0.77 (95% CI, 0.62–0.87) for minimum IVC diameter.[16] They also stated that the interrater reliability of measurement was increased from 0.49 to 0.81 after expiration and from 0.51 to 0.85 after inspiration at the end of the first 5 examinations. They study suggested that 15 USA examinations may be necessary to obtain sufficient skill. Akkaya et al. found that there was an increase in the interrater reliability of IVC-min measurements after 10 examinations.[17] In our study, the researchers who measured the IVC diameters had at least 2 years of experience in BUS. Hence, the difference in diameter between the two views may have been because of a change in angle of looking at the IVC. It is also logical that the percentage variation had narrower limits of agreement since we were not looking at a number but a qualitative percentage change in the diameter. Other factors can affect IVC diameter and its relationship to CVP. The liver or diaphragm may tend to tether the IVC in the “open” position in the most proximal portions but there is variation in the diameter of the IVC among normal patients, so it seems the tethering must not be preventing the change in IVC size. Changes in intraabdominal and intrathoracic pressures (e.g., during positive-pressure ventilation or Valsalva maneuver) are also well known to alter the CVP and have some effect on IVC diameters. Whether any of these factors does affect our ability at the bedside to infer CVP from the IVC diameter has not been well studied. We need to keep these limitations in mind. Therefore, we believe when the subcostal view is difficult to obtain, we can use the lateral transhepatic view, but instead of using actual diameter, we should use variation in diameter to determine volume status of the patient.

Conclusions

We conclude that when it is not possible to obtain the subcostal view, it is possible to use the lateral transhepatic view. However, using the percentage variation in IVC size is likely to be more reliable than the absolute diameter alone. It is possible to use both views interchangeably.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  16 in total

1.  American College of Emergency Physicians. ACEP emergency ultrasound guidelines-2001.

Authors: 
Journal:  Ann Emerg Med       Date:  2001-10       Impact factor: 5.721

2.  Early diagnosis of hypovolemic shock by sonographic measurement of inferior vena cava in trauma patients.

Authors:  Youichi Yanagawa; Kouichirou Nishi; Toshihisa Sakamoto; Yoshiaki Okada
Journal:  J Trauma       Date:  2005-04

3.  Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality.

Authors:  John H Boyd; Jason Forbes; Taka-aki Nakada; Keith R Walley; James A Russell
Journal:  Crit Care Med       Date:  2011-02       Impact factor: 7.598

4.  Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis.

Authors:  Joerg C Schefold; Christian Storm; Sven Bercker; Rene Pschowski; Michael Oppert; Anne Krüger; Dietrich Hasper
Journal:  J Emerg Med       Date:  2008-04-01       Impact factor: 1.484

5.  Vena cava diameter measurement for estimation of dry weight in haemodialysis patients.

Authors:  A Mandelbaum; E Ritz
Journal:  Nephrol Dial Transplant       Date:  1996       Impact factor: 5.992

6.  Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function.

Authors:  F L Moreno; A D Hagan; J R Holmen; T A Pryor; R D Strickland; C H Castle
Journal:  Am J Cardiol       Date:  1984-02-01       Impact factor: 2.778

7.  The interrater reliability of inferior vena cava ultrasound by bedside clinician sonographers in emergency department patients.

Authors:  J Matthew Fields; Paul A Lee; Katherine Y Jenq; Dustin G Mark; Nova L Panebianco; Anthony J Dean
Journal:  Acad Emerg Med       Date:  2011-01       Impact factor: 3.451

8.  Role of inferior vena cava diameter in assessment of volume status: a meta-analysis.

Authors:  Agarwal Dipti; Zachary Soucy; Alok Surana; Subhash Chandra
Journal:  Am J Emerg Med       Date:  2012-01-04       Impact factor: 2.469

9.  The respiratory variation in inferior vena cava diameter as a guide to fluid therapy.

Authors:  Marc Feissel; Frédéric Michard; Jean-Pierre Faller; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2004-03-25       Impact factor: 17.440

10.  Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.

Authors:  Christophe Barbier; Yann Loubières; Christophe Schmit; Jan Hayon; Jean-Louis Ricôme; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2004-03-18       Impact factor: 17.440

View more
  2 in total

1.  Malposition of the Extracorporeal Membrane Oxygenation Venous Cannula in an Accessory Hepatic Vein.

Authors:  Hadrien Winiszewski; Andrea Perrotti; Sidney Chocron; Gilles Capellier; Gaël Piton
Journal:  J Extra Corpor Technol       Date:  2018-09

2.  Comparison of Hemodynamic Monitoring between Transesophageal Doppler and Ultrasonography-Guided Inferior Vena Cava Distensibility in Supine versus Prone Position: A Pilot Study.

Authors:  Pralay Shankar Ghosh; Afzal Azim; Sai Saran; Arvind Kumar Baronia; Banani Poddar; Ratender Kumar Singh; Mohan Gurjar; Prabhaker Mishra
Journal:  Indian J Crit Care Med       Date:  2018-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.