Literature DB >> 26798075

Learning ECOC Code Matrix for Multiclass Classification with Application to Glaucoma Diagnosis.

Xiaolong Bai1,2, Swamidoss Issac Niwas3, Weisi Lin4, Bing-Feng Ju5, Chee Keong Kwoh6, Lipo Wang7, Chelvin C Sng8, Maria C Aquino9, Paul T K Chew10.   

Abstract

Classification of different mechanisms of angle closure glaucoma (ACG) is important for medical diagnosis. Error-correcting output code (ECOC) is an effective approach for multiclass classification. In this study, we propose a new ensemble learning method based on ECOC with application to classification of four ACG mechanisms. The dichotomizers in ECOC are first optimized individually to increase their accuracy and diversity (or interdependence) which is beneficial to the ECOC framework. Specifically, the best feature set is determined for each possible dichotomizer and a wrapper approach is applied to evaluate the classification accuracy of each dichotomizer on the training dataset using cross-validation. The separability of the ECOC codes is maximized by selecting a set of competitive dichotomizers according to a new criterion, in which a regularization term is introduced in consideration of the binary classification performance of each selected dichotomizer. The proposed method is experimentally applied for classifying four ACG mechanisms. The eye images of 152 glaucoma patients are collected by using anterior segment optical coherence tomography (AS-OCT) and then segmented, from which 84 features are extracted. The weighted average classification accuracy of the proposed method is 87.65 % based on the results of leave-one-out cross-validation (LOOCV), which is much better than that of the other existing ECOC methods. The proposed method achieves accurate classification of four ACG mechanisms which is promising to be applied in diagnosis of glaucoma.

Entities:  

Keywords:  Dichotomizers; Ensemble learning; Error-correcting-output-coding (ECOC); Feature selection; Glaucoma; Multiclass classification

Mesh:

Year:  2016        PMID: 26798075     DOI: 10.1007/s10916-016-0436-2

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  14 in total

1.  Lens vault, thickness, and position in Chinese subjects with angle closure.

Authors:  Monisha E Nongpiur; Mingguang He; Nishani Amerasinghe; David S Friedman; Wan-Ting Tay; Mani Baskaran; Scott D Smith; Tien Yin Wong; Tin Aung
Journal:  Ophthalmology       Date:  2010-10-29       Impact factor: 12.079

2.  Feature selection based on mutual information: criteria of max-dependency, max-relevance, and min-redundancy.

Authors:  Hanchuan Peng; Fuhui Long; Chris Ding
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2005-08       Impact factor: 6.226

3.  Reliable feature selection for automated angle closure glaucoma mechanism detection.

Authors:  S Issac Niwas; Weisi Lin; Xiaolong Bai; Chee Keong Kwoh; Chelvin C Sng; M Cecilia Aquino; P T K Chew
Journal:  J Med Syst       Date:  2015-02-08       Impact factor: 4.460

Review 4.  A review of feature selection techniques in bioinformatics.

Authors:  Yvan Saeys; Iñaki Inza; Pedro Larrañaga
Journal:  Bioinformatics       Date:  2007-08-24       Impact factor: 6.937

5.  On the decoding process in ternary error-correcting output codes.

Authors:  Sergio Escalera; Oriol Pujol; Petia Radeva
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2010-01       Impact factor: 6.226

6.  Automatic anterior chamber angle assessment for HD-OCT images.

Authors:  Jing Tian; Pina Marziliano; Mani Baskaran; Hong-Tym Wong; Tin Aung
Journal:  IEEE Trans Biomed Eng       Date:  2011-08-30       Impact factor: 4.538

7.  Multiclass from binary: expanding one-versus-all, one-versus-one and ECOC-based approaches.

Authors:  Anderson Rocha; Siome Klein Goldenstein
Journal:  IEEE Trans Neural Netw Learn Syst       Date:  2014-02       Impact factor: 10.451

8.  Automated diagnosis of glaucoma using digital fundus images.

Authors:  Jagadish Nayak; Rajendra Acharya U; P Subbanna Bhat; Nakul Shetty; Teik-Cheng Lim
Journal:  J Med Syst       Date:  2009-10       Impact factor: 4.460

9.  Long-term success of argon laser peripheral iridoplasty in the management of plateau iris syndrome.

Authors:  Robert Ritch; Clement C Y Tham; Dennis S C Lam
Journal:  Ophthalmology       Date:  2004-01       Impact factor: 12.079

10.  A framework for detecting glaucomatous progression in the optic nerve head of an eye using proper orthogonal decomposition.

Authors:  Madhusudhanan Balasubramanian; Stanislav Zabić; Christopher Bowd; Hilary W Thompson; Peter Wolenski; S Sitharama Iyengar; Bijaya B Karki; Linda M Zangwill
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-04-14
View more
  1 in total

1.  Novel Automated Approach to Predict the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes Using Anterior Segment Optical Coherence Tomography.

Authors:  Victor Koh; Issac Niwas Swamidoss; Maria Cecilia D Aquino; Paul T Chew; Chelvin Sng
Journal:  J Med Syst       Date:  2018-04-27       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.