Literature DB >> 26797019

Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

Iris H Y Kwok1, Scott J C Pallett2, Edward Massa2, Duncan Cundall-Curry2, Mark D Loeffler2.   

Abstract

Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Femoral neck; Fractures; Hemiarthroplasty; Hip; Templating

Mesh:

Year:  2015        PMID: 26797019     DOI: 10.1016/j.injury.2015.12.027

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  5 in total

1.  Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?

Authors:  Daniel Thurston; Saad El-Ashry; Sreenadh Gella; Kanthan Theivendran
Journal:  J Clin Orthop Trauma       Date:  2022-07-16

2.  How Accurate is the Use of Contralateral Implant Size as a Template in Bilateral Hemiarthroplasty?

Authors:  Raghavendra Marappa-Ganeshan; Francis Sim; Sameh Sidhom; Gautam Chakrabarty; Hemant G Pandit; Bernard H van Duren
Journal:  Indian J Orthop       Date:  2020-09-05       Impact factor: 1.251

3.  Conventional computed tomography software can be used for accurate pre-operative templating in bipolar hip arthroplasty: A preliminary report.

Authors:  Nobuaki Chinzei; Mitsuaki Noda; Hiroshi Nashiki; Takehiko Matsushita; Atsuyuki Inui; Shinya Hayashi
Journal:  J Clin Orthop Trauma       Date:  2020-09-06

4.  Hip Hemiarthroplasty in Neurologic or Cognitively Impaired Patients: A Case Series of Post-operative Dislocations.

Authors:  Robert Pearse Piggott; Emmett Karl Smithwick; Colin Gerard Murphy
Journal:  J Orthop Case Rep       Date:  2018 Jan-Feb

5.  Improving the accuracy of digital templating: achieving success through stakeholder management.

Authors:  Hammad Parwaiz; Boris Aliaga Crespo; Joshua Filer; Ashley Thorpe; Rosie Seatter; Dominique Suzanne Faulkner; Harvey Sandhu
Journal:  BMJ Open Qual       Date:  2019-06-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.