Literature DB >> 26792419

Pressure-dependent changes in haematocrit and plasma volume during anaesthesia, a randomised clinical trial.

T Damén1,2, B Reinsfelt1,2, B Redfors1,2, A Nygren1,2.   

Abstract

BACKGROUND: Induction of general anaesthesia has been shown to cause haemodilution and an increase in plasma volume. The aim of this study was to evaluate whether prevention of hypotension during anaesthesia induction could avoid haemodilution.
METHODS: Twenty-four cardiac surgery patients, 66 ± 10 years, were randomised to receive either norepinephrine in a dose needed to maintain mean arterial blood pressure (MAP) at pre-anaesthesia levels after induction or to a control group that received vasopressor if MAP decreased below 60 mmHg. No fluids were infused. Changes in plasma volume were calculated with standard formula: 100 × (Hct(pre)/Hct(post) - 1)/(1 - Hct(pre)). Arterial blood gas was analysed every 10 minutes and non-invasive continuous haemoglobin (SpHb) was continuously measured.
RESULTS: Pre-anaesthesia MAP was 98 ± 7 mmHg. Ten minutes after anaesthesia induction, the haematocrit decreased by 5.0 ± 2.5% in the control group compared with 1.2 ± 1.4% in the intervention group, which corresponds to increases in plasma volume by 310 ml and 85 ml respectively. MAP decreased to 69 ± 15 mmHg compared to 92 ± 10 mmHg in the intervention group. The difference maintained throughout the 70 min intervention period. The change in haemoglobin level measured by blood gas analysis could not be detected by SpHb measurement. The mean bias between the SpHb and blood gas haemoglobin was 15 g/l.
CONCLUSION: During anaesthesia induction, haematocrit decreases and plasma volume increases early and parallel to a decrease in blood pressure. This autotransfusion is blunted when blood pressure is maintained at pre-induction levels with norepinephrine.
© 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26792419     DOI: 10.1111/aas.12687

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  3 in total

1.  Impact of acute changes in perfusion index and blood pressure on the accuracy of non-invasive continuous hemoglobin concentration measurements during induction of anesthesia.

Authors:  Junichi Saito; Masato Kitayama; Erika Amanai; Kentaro Toyooka; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2017-01-09       Impact factor: 2.078

2.  Perioperative blood loss: estimation of blood volume loss or haemoglobin mass loss?

Authors:  Sebastian Jaramillo; Mar Montane-Muntane; Pedro L Gambus; David Capitan; Ricard Navarro-Ripoll; Annabel Blasi
Journal:  Blood Transfus       Date:  2019-11-27       Impact factor: 3.443

3.  Effects of different mean arterial pressure targets on plasma volume, ANP and glycocalyx-A randomized trial.

Authors:  Tor Damén; Sofia Saadati; Eva Forssell-Aronsson; Camilla Hesse; Peter Bentzer; Sven-Erik Ricksten; Andreas Nygren
Journal:  Acta Anaesthesiol Scand       Date:  2020-10-05       Impact factor: 2.105