Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography.

Rukiye Dumanli1, Azade Attar2, Vildan Erci3, Ibrahim Isildak4.   

Abstract

A microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion- and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na(+)), potassium (K(+)), ammonium (NH4 (+)), chloride (Cl(-)) and nitrate (NO3 (-)) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixed-bed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 µM for the anions and 0.3 to 3.0 µM for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26786906      PMCID: PMC4885397          DOI: 10.1093/chromsci/bmv193

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  25 in total

1.  Simultaneous separation of inorganic anions and cations by using anion-exchange and cation-exchange columns connected in tandem in ion chromatography.

Authors:  Khairil Juhanni Binti Abd Karim; Ji-Ye Jin; Toyohide Takeuchi
Journal:  J Chromatogr A       Date:  2003-05-02       Impact factor: 4.759

2.  Physiological and pharmacological regulation of human salivary electrolyte concentrations; with a discussion of electrolyte concentrations of some other exocrine secretions.

Authors:  A G WHITE; P S ENTMACHER; G RUBIN; L LEITER
Journal:  J Clin Invest       Date:  1955-02       Impact factor: 14.808

3.  Anion chromatography using on-line recycled eluents.

Authors:  Takashi Yokoyama; Hitoe Maekubo; Asami Sakai; Michio Zenki
Journal:  J Chromatogr A       Date:  2005-09-30       Impact factor: 4.759

4.  Tunable separation of anions and cations by column switching in ion chromatography.

Authors:  Muhammad Amin; Lee Wah Lim; Toyohide Takeuchi
Journal:  Talanta       Date:  2006-08-24       Impact factor: 6.057

5.  Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography.

Authors:  I Isildak; A Asan
Journal:  Talanta       Date:  1999-04       Impact factor: 6.057

6.  Salivary sodium-potassium ratio and plasma renin activity in hypertension.

Authors:  V Adlin; B J Channick; A D Marks
Journal:  Circulation       Date:  1969-05       Impact factor: 29.690

7.  Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography.

Authors:  Shuchao Wu; Wei Xu; Bingcheng Yang; Mingli Ye; Peimin Zhang; Chao Shen-Tu; Yan Zhu
Journal:  Anal Chim Acta       Date:  2012-05-19       Impact factor: 6.558

8.  Suppressed anion chromatography using mixed zwitter-ionic and carbonate eluents.

Authors:  Yongjing Chen; Li Jing; Xiuling Li; Yan Zhu
Journal:  J Chromatogr A       Date:  2006-02-03       Impact factor: 4.759

9.  A new tool for inorganic nitrogen speciation study: simultaneous determination of ammonium ion, nitrite and nitrate by ion chromatography with post-column ammonium derivatization by Nessler reagent and diode-array detection in rain water samples.

Authors:  Przemysław Niedzielski; Iwona Kurzyca; Jerzy Siepak
Journal:  Anal Chim Acta       Date:  2006-06-27       Impact factor: 6.558

10.  A novel ion chromatography cycling-column-switching system for the determination of low-level chlorate and nitrite in high salt matrices.

Authors:  Nani Wang; Rui Qi Wang; Yan Zhu
Journal:  J Hazard Mater       Date:  2012-07-25       Impact factor: 10.588

View more
  1 in total

1.  Addressing the Detection of Ammonium Ion in Environmental Water Samples via Tandem Potentiometry-Ion Chromatography.

Authors:  Renato L Gil; Célia G Amorim; Maria Cuartero
Journal:  ACS Meas Sci Au       Date:  2022-01-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.