Literature DB >> 26774313

In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.

Kwang Yong Kelvin Khng1, Ronald L Ettinger2, Steven R Armstrong3, Terry Lindquist4, David G Gratton4, Fang Qian5.   

Abstract

STATEMENT OF PROBLEM: The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated.
PURPOSE: The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns.
MATERIAL AND METHODS: A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown.
RESULTS: The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (P<.001). At the facial margin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (P<.001). However, the mean percentage dye penetration was significantly correlated with the vertical and horizontal marginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (P<.01 in each instance).
CONCLUSIONS: A significantly smaller vertical marginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns; however, this difference was not observed for the horizontal component. The percentage dye penetration was correlated with vertical and horizontal discrepancies at the facial surface for the Jet interim crowns and with horizontal discrepancies at the lingual surface for the Caulk interim crowns.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26774313     DOI: 10.1016/j.prosdent.2015.10.002

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

Review 1.  Physical and Mechanical Properties of 3D-Printed Provisional Crowns and Fixed Dental Prosthesis Resins Compared to CAD/CAM Milled and Conventional Provisional Resins: A Systematic Review and Meta-Analysis.

Authors:  Saurabh Jain; Mohammed E Sayed; Mallika Shetty; Saeed M Alqahtani; Mohammed Hussain Dafer Al Wadei; Shilpi Gilra Gupta; Ahlam Abdulsalam Ahmed Othman; Abdulkarim Hussain Alshehri; Hatem Alqarni; Abdulaziz Hussain Mobarki; Khalid Motlaq; Haifa F Bakmani; Asma A Zain; Abdullah J Hakami; Moayad F Sheayria
Journal:  Polymers (Basel)       Date:  2022-06-30       Impact factor: 4.967

2.  Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.

Authors:  Wan-Sun Lee; Du-Hyeong Lee; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

3.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

4.  Accuracy evaluation of 3D printed interim prosthesis fabrication using a CBCT scanning based digital model.

Authors:  Young Hyun Kim; Bock-Young Jung; Sang-Sun Han; Chang-Woo Woo
Journal:  PLoS One       Date:  2020-10-16       Impact factor: 3.240

5.  Bond strength and microleakage of different types of cements in stainless steel crown of primary molar teeth.

Authors:  Somayeh Kameli; Fatemeh Khani; Marjan Bahraminasab; Raheb Ghorbani; Fatemeh Mashhadi Abbas
Journal:  Dent Res J (Isfahan)       Date:  2021-07-19

6.  Effect of Different CAD/CAM Milling and 3D Printing Digital Fabrication Techniques on the Accuracy of PMMA Working Models and Vertical Marginal Fit of PMMA Provisional Dental Prosthesis: An In Vitro Study.

Authors:  Marina Sidhom; Hanaa Zaghloul; Ihab El-Sayed Mosleh; Elzahraa Eldwakhly
Journal:  Polymers (Basel)       Date:  2022-03-22       Impact factor: 4.329

7.  Marginal Fit of Temporary Restorations Fabricated by the Conventional Chairside Method, 3D Printing, and Milling.

Authors:  Mahsa Mohajeri; Sara Khazaei; Fariborz Vafaee; Farnaz Firouz; Somayeh Ghorbani Gholiabad; Arash Shisheian
Journal:  Front Dent       Date:  2021-09-05

8.  Marginal adaptation of three-unit interim restorations fabricated by the CAD-CA systems and the direct method before and after thermocycling.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Mehran Falahchai; Hasan Tadbiri
Journal:  J Clin Exp Dent       Date:  2021-06-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.