| Literature DB >> 26770754 |
Hiroshi Fujita1, Kenya Nasu2, Mitsuyasu Terashima2, Tsuyoshi Ito1, Tomomitsu Tani1, Takahiko Suzuki2, Nobuyuki Ohte1.
Abstract
BACKGROUND: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing.Entities:
Keywords: Bare metal stent; dialysis; drug-eluting stent; major adverse cardiac events
Year: 2014 PMID: 26770754 PMCID: PMC4712748 DOI: 10.1177/2050312114562395
Source DB: PubMed Journal: SAGE Open Med ISSN: 2050-3121
Patient characteristics.
| BMS | DES | ||
|---|---|---|---|
| Number of patients | 36 | 58 | |
| Age, mean ± | 63.12 ± 9.42 | 65.17 ± 9.65 | 0.54 |
| Male, | 25 (69) | 43 (74) | 0.64 |
| Diabetes, | 17 (47) | 35 (60) | 0.29 |
| Hypertension, | 20 (56) | 43 (74) | 0.07 |
| Hyperlipidemia, | 5 (14) | 12 (21) | 0.58 |
| Current smoking, | 4 (11) | 12 (21) | 0.27 |
| Family history, | 4 (11) | 5 (8) | 0.73 |
| Prior CABG, | 18 (50) | 36 (62) | 0.29 |
| Prior MI, | 3 (8) | 2 (3) | 0.37 |
| 1VD/2VD/3VD | 6/12/18 | 4/22/32 | 0.54 |
BMS: bare metal stent; DES: drug-eluting stent; SD: standard deviation; CABG: coronary artery bypass grafting; MI: myocardial infarction; VD: vessel disease.
Lesion characteristics.
| BMS | DES | ||
|---|---|---|---|
| Number of lesions | 43 | 88 | |
| Treated vessel | |||
| LMT | 5 | 5 | 0.3 |
| LAD | 12 | 27 | 0.84 |
| LCX | 8 | 16 | 0.95 |
| RCA | 18 | 40 | 0.71 |
| AHA/ACC lesion type | |||
| A | 0 | 0 | NA |
| B1 | 5 (12) | 1 (1) | 0.007 |
| B2 | 21 (49) | 57 (65) | 0.09 |
| C | 17 (40) | 30 (34) | 0.57 |
| Angiographic calcification | 36 (84) | 77 (86) | 0.59 |
| Bending | 10 (23) | 29 (33) | 0.31 |
| Significant side branch | 6 (14) | 24 (27) | 0.12 |
BMS: bare metal stent; DES: drug-eluting stent; LMT: left mine trunk; LAD: left anterior descending; LCX: left circumflex; RCA: right coronary artery; AHA/ACC: American Heart Association/American College of Cardiology.
Data are presented as number (%) of patients.
Procedure data.
| BMS | DES | ||
|---|---|---|---|
| Number of lesions | 43 | 88 | |
| Procedure before stenting | |||
| POBA, % | 84 | 88 | 0.56 |
| Rotablator, % | 42 | 47 | 0.61 |
| DCA, % | 2 | 0 | 0.15 |
| Direct stent, % | 2 | 8 | 0.21 |
| Mean number of stents | 1.14 | 1.41 | 0.014 |
| Mean stent diameter, mm | 3.45 ± 0.45 | 3.10 ± 0.37 | <0.0001 |
| Mean stent length, mm | 19.79 ± 9.97 | 33.12 ± 18.58 | <0.0001 |
| Post-dilatation balloon, mm | 3.48 ± 0.52 | 3.22 ± 0.39 | 0.0023 |
| Post-dilatation pressure, atm | 17.64 ± 4.13 | 19.67 ± 3.22 | 0.0033 |
BMS: bare metal stent; DES: drug-eluting stent; POBA: plain old balloon angioplasty; DCA: directional coronary atherectomy.
Data are presented as mean ± standard deviation (SD), or number (%) of patients.
Figure 1.Cumulative distribution of post-procedure and 9-month follow-up minimal lumen diameter (mm) in the two groups. The post-procedure acute gain in the BMS group was well maintained throughout the follow-up period.
BMS: bare metal stent. DMS: drug eluting stent.
Quantitative angiographic follow-up data.
| BMS | DES | ||
|---|---|---|---|
| Number of lesions | 43 | 88 | |
| Pre-procedure | |||
| Lesion length, mm | 18.32 ± 9.84 | 20.93 ± 11.11 | 0.47 |
| Reference diameter, mm | 3.39 ± 1.03 | 3.09 ± 0.56 | 0.06 |
| Minimal lumen diameter, mm | 1.05 ± 0.55 | 1.00 ± 0.50 | 0.62 |
| % diameter stenosis | 68.08 ± 17.70 | 67.63 ± 15.03 | 0.89 |
| Post-procedure | |||
| Reference diameter, mm | 3.55 ± 0.90 | 3.35 ± 0.59 | 0.16 |
| Minimal lumen diameter, mm | 3.15 ± 0.81 | 2.84 ± 0.50 | 0.014 |
| % diameter stenosis | 10.77 ± 10.89 | 13.93 ± 10.35 | 0.47 |
| Follow-up at 9 months | 38 (88) | 70 (80) | |
| Minimal lumen diameter, mm | 2.16 ± 0.86 | 1.84 ± 0.88 | 0.014 |
| % diameter stenosis | 34.29 ± 17.72 | 37.63 ± 27.90 | 0.52 |
| Late lumen loss, mm | 0.96 ± 0.57 | 1.00 ± 0.94 | 0.83 |
| Binary restenosis, | 7 (18) | 27 (39) | 0.031 |
BMS: bare metal stent; DES: drug-eluting stent.
Data are presented as mean ± standard deviation (SD) or number (%) of patients.
Clinical follow-up data.
| BMS | DES | ||
|---|---|---|---|
| Clinical follow-up | |||
| Number of patients | 33 (92) | 53 (91) | |
| MACE overall | 7 (21) | 28 (53) | 0.0037 |
| All death | 1 (3) | 3 (6) | 0.56 |
| Cardiac death | 1 (3) | 1 (2) | 0.73 |
| Myocardial infarction | |||
| (Q and non-Q-wave) | 0 (0) | 0 (0) | – |
| CHF | 0 (0) | 1 (1) | 0.43 |
| TLR | 6 (18) | 26 (49) | 0.004 |
BMS: bare metal stent; DES: drug-eluting stent; MACE: major adverse cardiac event; CHF: congestive heart disease; TLR: target lesion revascularization.
All data are presented as n (%).