Literature DB >> 26766399

Needle Revision With 5-fluorouracil for the Treatment of Ahmed Glaucoma Valve Filtering Blebs: 5-Fluoruracil Needling Revision can be a Useful and Safe Tool in the Management of Failing Ahmed Glaucoma Valve Filtering Blebs.

Luciano Quaranta1, Irene Floriani, Lital Hollander, Davide Poli, Andreas Katsanos, Anastasios G P Konstas.   

Abstract

PURPOSE: To determine the outcome of needling with adjunctive 5-fluorouracil (5-FU) in patients with a failing Ahmed glaucoma valve (AGV) implant, and to identify predictors of long-term intraocular pressure (IOP) control.
METHODS: A prospective observational study was performed on consecutive patients with medically uncontrolled primary open-angle glaucoma (POAG) with AGV encapsulation or fibrosis and inadequate IOP control. Bleb needling with 5-FU injection (0.1 mL of 50 mg/mL) was performed at the slit-lamp. Patients were examined 1 week following the needling, and then at months 1, 3, and 6. Subsequent follow-up visits were scheduled at 6-month intervals for at least 2 years. Needling with 5-FU was repeated no more than twice during the first 3 months of the follow-up. Procedure outcome was determined on the basis of the recorded IOP levels.
RESULTS: Thirty-six patients with an encapsulated or fibrotic AGV underwent 67procedures (mean 1.86 ± 0.83). Complete success, defined as IOP ≤ 18 mm Hg without medications, was obtained in 25% at 24 months of observation. The cumulative proportion of cases achieving either qualified (ie, IOP ≤ 18 mm Hg with medications) or complete success at 24 months of observation was 72.2%. In a univariate Cox proportional hazards model, age was the only variable that independently influenced the risk of failing 5-FU needling revision. Fourteen eyes (38.8%) had a documented complication.
CONCLUSIONS: Needling over the plate of an AGV supplemented with 5-FU is an effective and safe choice in a significant proportion of POAG patients with elevated IOP due to encapsulation or fibrosis.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26766399     DOI: 10.1097/IJG.0000000000000366

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  9 in total

1.  Use of subconjunctival injections of 5-fluorouracil to rescue and prolong intraocular pressure reduction for a failing Ahmed glaucoma implant.

Authors:  Kevin Kaplowitz; James C Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-08-11       Impact factor: 3.117

2.  Subconjunctival injections of 5-fluorouracil for failing Ahmed glaucoma implants.

Authors:  Luciano Quaranta; Andreas Katsanos; Lorenzo Legramandi; Ivano Riva
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-08-09       Impact factor: 3.117

3.  Long-term outcomes of uveitic glaucoma treated with Ahmed valve implant in a series of Chinese patients.

Authors:  Ning Bao; Zheng-Xuan Jiang; Paul Coh; Li-Ming Tao
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

4.  The role of primary needle revision after Ahmed glaucoma valve (AGV) implantation.

Authors:  Maryam Yadgari; Kiana Hassanpour; Fatemeh Vafaei
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

Review 5.  Ahmed glaucoma valve implant: surgical technique and complications.

Authors:  Ivano Riva; Gloria Roberti; Francesco Oddone; Anastasios Gp Konstas; Luciano Quaranta
Journal:  Clin Ophthalmol       Date:  2017-02-17

6.  Comparison of 1-year outcomes after Ahmed glaucoma valve implantation with and without Ologen adjuvant.

Authors:  Tai Jun Kim; Sohyun Kang; Jin Wook Jeoung; Young Kook Kim; Ki Ho Park
Journal:  BMC Ophthalmol       Date:  2018-02-14       Impact factor: 2.209

7.  Development of a biodegradable antifibrotic local drug delivery system for glaucoma microstents.

Authors:  Thomas Stahnke; Stefan Siewert; Thomas Reske; Wolfram Schmidt; Klaus-Peter Schmitz; Niels Grabow; Rudolf F Guthoff; Andreas Wree
Journal:  Biosci Rep       Date:  2018-08-31       Impact factor: 3.840

8.  Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation.

Authors:  Seong Eun Lee; Kyoung Nam Kim; Woo Jin Kim; Sung Bok Lee; Chang Sik Kim
Journal:  Korean J Ophthalmol       Date:  2019-06

9.  Ahmed Glaucoma Valves versus EX-PRESS Devices in Glaucoma Secondary to Silicone Oil Emulsification.

Authors:  Zhuyun Qian; Kai Xu; Xiangmei Kong; Huan Xu
Journal:  J Ophthalmol       Date:  2018-06-20       Impact factor: 1.909

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.