Literature DB >> 26765746

Rapid quantitative T2 mapping of the prostate using three-dimensional dual echo steady state MRI at 3T.

Isabel Dregely1, Daniel A J Margolis1, Kyunghyun Sung1, Ziwu Zhou1, Novena Rangwala1, Steven S Raman1, Holden H Wu1.   

Abstract

PURPOSE: To develop and evaluate a rapid three-dimensional (3D) quantitative T2 mapping method for prostate cancer imaging using dual echo steady state (DESS) MRI at 3T.
METHODS: In simulations, DESS-T2 mapping in the presence of T1 and B1+ variations was evaluated. In a phantom and in healthy volunteers (n = 4), 3D DESS-T2 mapping was compared with a two-dimensional turbo spin echo (TSE) approach. In volunteers and a pilot patient study (n = 29), quantitative T2 in normal prostate anatomical zones and in suspected cancerous lesions was evaluated.
RESULTS: The simulated bias for DESS-T2 was < 2% (5%) for typically observed T1 ( B1+) variations. In phantoms and in vivo, high correlation of DESS-T2 and TSE-T2 (r2  = 0.98 and 0.88, P < 0.001) was found. DESS-T2 in the normal peripheral zone and transition zone was 115 ± 26 ms and 64 ± 7 ms, respectively, in healthy volunteers and 129 ± 39 ms and 83 ± 12 ms, respectively, in patients. In suspected cancerous lesions, DESS-T2 was 72 ± 14 ms, which was significantly decreased from the normal peripheral zone (P < 0.001) but not from the transition zone.
CONCLUSION: Rapid 3D T2 mapping in the entire prostate can be performed in 1 min using DESS MRI. Magn Reson Med 76:1720-1729, 2016.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  3T MRI; T2 mapping; dual echo steady state (DESS) MRI; prostate cancer imaging

Mesh:

Year:  2016        PMID: 26765746     DOI: 10.1002/mrm.26053

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  3D MR fingerprinting with accelerated stack-of-spirals and hybrid sliding-window and GRAPPA reconstruction.

Authors:  Congyu Liao; Berkin Bilgic; Mary Kate Manhard; Bo Zhao; Xiaozhi Cao; Jianhui Zhong; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2017-08-24       Impact factor: 6.556

2.  A simple analytic method for estimating T2 in the knee from DESS.

Authors:  B Sveinsson; A S Chaudhari; G E Gold; B A Hargreaves
Journal:  Magn Reson Imaging       Date:  2016-12-23       Impact factor: 2.546

3.  SNR-weighted regularization of ADC estimates from double-echo in steady-state (DESS).

Authors:  Bragi Sveinsson; Garry E Gold; Brian A Hargreaves; Daehyun Yoon
Journal:  Magn Reson Med       Date:  2018-08-19       Impact factor: 4.668

4.  Clinical utility of combined T2-weighted imaging and T2-mapping in the detection of prostate cancer: a multi-observer study.

Authors:  Chau Hung Lee; Matthias Taupitz; Patrick Asbach; Julian Lenk; Matthias Haas
Journal:  Quant Imaging Med Surg       Date:  2020-09

5.  Performance of a fast and high-resolution multi-echo spin-echo sequence for prostate T2 mapping across multiple systems.

Authors:  Petra J van Houdt; Harsh K Agarwal; Laurens D van Buuren; Stijn W T P J Heijmink; Søren Haack; Henk G van der Poel; Ghazaleh Ghobadi; Floris J Pos; Johannes M Peeters; Peter L Choyke; Uulke A van der Heide
Journal:  Magn Reson Med       Date:  2017-07-03       Impact factor: 4.668

6.  Utilizing shared information between gradient-spoiled and RF-spoiled steady-state MRI signals.

Authors:  Bragi Sveinsson; Garry E Gold; Brian A Hargreaves; Daehyun Yoon
Journal:  Phys Med Biol       Date:  2021-01-14       Impact factor: 3.609

7.  Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach.

Authors:  Yaghoub Fatemi; Habibollah Danyali; Mohammad Sadegh Helfroush; Houshang Amiri
Journal:  Magn Reson Med       Date:  2020-05-19       Impact factor: 4.668

8.  Accelerated 3D T2 w-imaging of the prostate with 1-millimeter isotropic resolution in less than 3 minutes.

Authors:  Rohini Vidya Shankar; Elisa Roccia; Gastao Cruz; Radhouene Neji; René Botnar; Davide Prezzi; Vicky Goh; Claudia Prieto; Isabel Dregely
Journal:  Magn Reson Med       Date:  2019-04-21       Impact factor: 4.668

Review 9.  Imaging biomarkers in oncology: Basics and application to MRI.

Authors:  Isabel Dregely; Davide Prezzi; Christian Kelly-Morland; Elisa Roccia; Radhouene Neji; Vicky Goh
Journal:  J Magn Reson Imaging       Date:  2018-07       Impact factor: 4.813

10.  Multiple-echo steady-state (MESS): Extending DESS for joint T2 mapping and chemical-shift corrected water-fat separation.

Authors:  Frank Zijlstra; Peter R Seevinck
Journal:  Magn Reson Med       Date:  2021-07-16       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.