Does measurement of four-limb blood pressures at birth improve detection of aortic arch anomalies?

N Patankar1, N Fernandes1, K Kumar1, V Manja2, S Lakshminrusimha1.   

Abstract

OBJECTIVE: To determine normal four-extremity blood pressure (BP) in the neonatal intensive care unit (NICU) at birth and the utility of upper (UE) and lower extremity (LE) BP difference to screen for coarctation of the aorta (Co-A) and interrupted the aortic arch (IAA). STUDY
DESIGN: Retrospective study of BP at birth (n=866), and case-control study of Co-A/IAA infants and matched controls (1:2). RESULT: Although BP increased with gestational age (R(2)=0.3, P<0.0001), the pressure gradient between UE and LE did not change with gestation (P=0.68). Forty-six cases of Co-A/IAA were identified, with 92 controls. Pressure gradient was significantly higher in patients with Co-A/IAA (7.6±14.8 versus 0.4±10 mm Hg, P=0.004). However, there was overlap between cases and controls resulting in low sensitivity (41.3% with ⩾10 mm Hg gradient cutoff).
CONCLUSION: Evaluation of UE-LE BP gradient at birth is a poor screening test for Co-A/IAA with low sensitivity. Repeating four-limb BP after ductal closure at 24 to 48 h along with SpO2 screening for critical congenital heart disease may increase sensitivity.

Entities:  

Mesh:

Year:  2016        PMID: 26765554      PMCID: PMC4844785          DOI: 10.1038/jp.2015.203

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  19 in total

1.  Non-invasive blood pressure measurements and aortic blood flow velocity in neonates.

Authors:  E Rahiala; T Tikanoja
Journal:  Early Hum Dev       Date:  1997-09-19       Impact factor: 2.079

Review 2.  Blood pressure in the neonate.

Authors:  A Michael Weindling; Jamie Bentham
Journal:  Acta Paediatr       Date:  2005-02       Impact factor: 2.299

3.  Blood pressure patterns in the first three days of life.

Authors:  S Hulman; R Edwards; Y Q Chen; M Polansky; B Falkner
Journal:  J Perinatol       Date:  1991-09       Impact factor: 2.521

4.  Suspicion of aortic coarctation in an outpatient clinic: how should blood pressure measurements be performed?

Authors:  E Rahiala; T Tikanoja
Journal:  Clin Physiol       Date:  2001-01

5.  Normative arm and calf blood pressure values in the newborn.

Authors:  M K Park; D H Lee
Journal:  Pediatrics       Date:  1989-02       Impact factor: 7.124

6.  Late Diagnosis of Coarctation Despite Prenatal Ultrasound and Postnatal Pulse Oximetry.

Authors:  Katarina Lannering; Marie Bartos; Mats Mellander
Journal:  Pediatrics       Date:  2015-07-13       Impact factor: 7.124

7.  Oscillometric blood pressures in the arm, thigh, and calf in healthy children and those with aortic coarctation.

Authors:  M K Park; D H Lee; G A Johnson
Journal:  Pediatrics       Date:  1993-04       Impact factor: 7.124

8.  Calf blood pressure: clinical implications and correlations with arm blood pressure in infants and young children.

Authors:  M S Crapanzano; W B Strong; I R Newman; R L Hixon; D Casal; C W Linder
Journal:  Pediatrics       Date:  1996-02       Impact factor: 7.124

9.  Variability of four limb blood pressure in normal neonates.

Authors:  D S Crossland; J C Furness; M Abu-Harb; S N Sadagopan; C Wren
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-07       Impact factor: 5.747

10.  Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns.

Authors:  Anne de-Wahl Granelli; Margareta Wennergren; Kenneth Sandberg; Mats Mellander; Carina Bejlum; Leif Inganäs; Monica Eriksson; Niklas Segerdahl; Annelie Agren; Britt-Marie Ekman-Joelsson; Jan Sunnegårdh; Mario Verdicchio; Ingegerd Ostman-Smith
Journal:  BMJ       Date:  2009-01-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.