L D J Fiederer1, J Vorwerk2, F Lucka3, M Dannhauer4, S Yang5, M Dümpelmann6, A Schulze-Bonhage7, A Aertsen8, O Speck9, C H Wolters2, T Ball10. 1. Intracranial EEG and Brain Imaging Lab, Epilepsy Center, University Hospital Freiburg, Germany; Neurobiology and Biophysics, Faculty of Biology, University of Freiburg, Germany; BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, Germany. Electronic address: lukas.fiederer@uniklinik-freiburg.de. 2. Institute for Biomagnetism and Biosignalanalysis, University of Münster, Germany. 3. Institute for Biomagnetism and Biosignalanalysis, University of Münster, Germany; Institute for Computational and Applied Mathematics, University of Münster, Germany; Department of Computer Science, University College London, WC1E 6BT London, UK. 4. Scientific Computing and Imaging Institute, 72 So. Central Campus Drive, Salt Lake City, Utah 84112, USA; Center for Integrative Biomedical Computing, University of Utah, 72 S. Central Campus Drive, 84112, Salt Lake City, UT, USA. 5. Dept. of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Germany. 6. Intracranial EEG and Brain Imaging Lab, Epilepsy Center, University Hospital Freiburg, Germany; BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Germany. 7. BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, Germany. 8. Neurobiology and Biophysics, Faculty of Biology, University of Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, Germany. 9. Dept. of Biomedical Magnetic Resonance, Otto-von-Guericke University Magdeburg, Germany; Leibniz Institute for Neurobiology, Magdeburg, Germany; German Center for Neurodegenerative Diseases (DZNE), Site Magdeburg, Germany; Center for Behavioral Brain Sciences, Magdeburg, Germany. 10. Intracranial EEG and Brain Imaging Lab, Epilepsy Center, University Hospital Freiburg, Germany; BrainLinks-BrainTools Cluster of Excellence, University of Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, Germany.
Abstract
Reconstruction of the electrical sources of human EEG activity at high spatio-temporal accuracy is an important aim in neuroscience and neurological diagnostics. Over the last decades, numerous studies have demonstrated that realistic modeling of head anatomy improves the accuracy of source reconstruction of EEG signals. For example, including a cerebro-spinal fluid compartment and the anisotropy of white matter electrical conductivity were both shown to significantly reduce modeling errors. Here, we for the first time quantify the role of detailed reconstructions of the cerebral blood vessels in volume conductor head modeling for EEG. To study the role of the highly arborized cerebral blood vessels, we created a submillimeter head model based on ultra-high-field-strength (7T) structural MRI datasets. Blood vessels (arteries and emissary/intraosseous veins) were segmented using Frangi multi-scale vesselness filtering. The final head model consisted of a geometry-adapted cubic mesh with over 17×10(6) nodes. We solved the forward model using a finite-element-method (FEM) transfer matrix approach, which allowed reducing computation times substantially and quantified the importance of the blood vessel compartment by computing forward and inverse errors resulting from ignoring the blood vessels. Our results show that ignoring emissary veins piercing the skull leads to focal localization errors of approx. 5 to 15mm. Large errors (>2cm) were observed due to the carotid arteries and the dense arterial vasculature in areas such as in the insula or in the medial temporal lobe. Thus, in such predisposed areas, errors caused by neglecting blood vessels can reach similar magnitudes as those previously reported for neglecting white matter anisotropy, the CSF or the dura - structures which are generally considered important components of realistic EEG head models. Our findings thus imply that including a realistic blood vessel compartment in EEG head models will be helpful to improve the accuracy of EEG source analyses particularly when high accuracies in brain areas with dense vasculature are required.
Reconstruction of the electrical sources of human EEG activity at high spatio-temporal accuracy is an important aim in neuroscience and neurological diagnostics. Over the last decades, numerous studies have demonstrated that realistic modeling of head anatomy improves the accuracy of source reconstruction of EEG signals. For example, including a cerebro-spinal fluid compartment and the anisotropy of white matter electrical conductivity were both shown to significantly reduce modeling errors. Here, we for the first time quantify the role of detailed reconstructions of the cerebral blood vessels in volume conductor head modeling for EEG. To study the role of the highly arborized cerebral blood vessels, we created a submillimeter head model based on ultra-high-field-strength (7T) structural MRI datasets. Blood vessels (arteries and emissary/intraosseous veins) were segmented using Frangi multi-scale vesselness filtering. The final head model consisted of a geometry-adapted cubic mesh with over 17×10(6) nodes. We solved the forward model using a finite-element-method (FEM) transfer matrix approach, which allowed reducing computation times substantially and quantified the importance of the blood vessel compartment by computing forward and inverse errors resulting from ignoring the blood vessels. Our results show that ignoring emissary veins piercing the skull leads to focal localization errors of approx. 5 to 15mm. Large errors (>2cm) were observed due to the carotid arteries and the dense arterial vasculature in areas such as in the insula or in the medial temporal lobe. Thus, in such predisposed areas, errors caused by neglecting blood vessels can reach similar magnitudes as those previously reported for neglecting white matter anisotropy, the CSF or the dura - structures which are generally considered important components of realistic EEG head models. Our findings thus imply that including a realistic blood vessel compartment in EEG head models will be helpful to improve the accuracy of EEG source analyses particularly when high accuracies in brain areas with dense vasculature are required.
Realistic head models are important tools in neuroscience (Pascual-Marqui, 1999; Michel et al., 2004; Grech et al.,
2008; Michel and Murray, 2012;
Schneider, 1972; Opitz et al., 2011; Datta
et al., 2013; Sadleir et al.,
2010; Fernández-Corazza et al.,
2013; Bayford and Tizzard, 2012;
Vonach et al., 2012; Carter et al., 2005; Miller et al., 2010; Voo et al.,
1996; Yang et al., 2009; Panzer et al., 2012; Wendel et al., 2009; Lau
et al., 2014; Heers et al., 2012;
Rampp and Stefan, 2007). The present
paper focuses on realistic head models for EEG research that are used as volume
conductor head models (VCHMs) for computing the electric fields created by
electrical sources in the brain. VCHMs enable to study the influence of detailed
anatomy on field propagation (Opitz et al.,
2011; Ramon et al., 2006; Haueisen et al., 1997) and the optimal spatial
sampling of EEG signals (Ramon et al., 2009;
Slutzky et al., 2010; Srinivasan et al., 1998) and are essential for source
localization (Pascual-Marqui, 1999; Michel et al., 2004; Grech et al., 2008; Michel and Murray, 2012; Schneider,
1972).For these applications, simplified spherical shell (Brazier, 1949; Geisler
and Gerstein, 1961; Frank, 1952;
Wilson and Bayley, 1950; Hosek et al., 1978; Meijs
and Peters, 1987) models can be used and solved with analytical methods,
but they neglect the complex anatomy of the head and the brain. Numerous studies
have demonstrated that realistic modeling of anatomical structures such as the skull
(Dannhauer et al., 2011; Ramon et al., 2004; Chauveau et al., 2004; Lanfer et al.,
2012a; Anwander et al., 2002; Ary et al., 1981; Cuffin, 1993; van den
Broek et al., 1998; Vorwerk et al.,
2014), the dura (Slutzky et al.,
2010; Ramon et al., 2014; Ramon, 2012), the cerebrospinal fluid (CSF)
(Ramon et al., 2006; Haueisen et al., 1997; Slutzky et al., 2010; Ramon et al.,
2004; van den Broek et al., 1998;
Vorwerk et al., 2014; Bangera et al., 2010; Bénar and Gotman, 2002; Lanfer
et al., 2012b; Rice et al., 2013;
Vanrumste et al., 2000; Wendel et al., 2008) and head extent (Lanfer et al., 2012a; Bruno et al., 2003; Vatta et al.,
2005) as well as realistic modeling of anisotropy (Chauveau et al., 2004; Anwander et al., 2002; Vorwerk et al.,
2014; Bangera et al., 2010; Haueisen et al., 2002; Güllmar et al., 2010; Wolters et al., 2006; Hallez et al., 2005, 2008, 2009; Rullmann
et al., 2009; Wolters, 2003),
particularly of the white matter, can substantially improve the accuracy of forward
and inverse modeling of EEG signals. The strong concerns related to anisotropy even
prompted the development of new modeling methods to enable its implementation (Hallez et al., 2005; Wolters, 2003). Thus, most aspects of the cranial
macro-anatomy have meanwhile been addressed in previous head modeling studies.One exception, though, is the role of cranial blood vessels for EEG forward
and inverse solutions which has only been marginally addressed so far (Haueisen et al., 1997). As the influences of
gray matter, white matter, CSF, dura and skull have all been addressed, blood
vessels might be the last uninvestigated widespread macroscopic structure within the
bounds of the skull. One reason for this has been the difficulty in obtaining
detailed reconstructions of the complex, highly arborized cerebral blood vessels
from available imaging data for VCHMs, in particular without application of contrast
agents. The role of blood vessels in VCHMs however deserves attention as (i) the
brain is strongly vascularized and, hence, a large number of blood vessels of
different calibers are present throughout the skull and brain. Blood vessels not
only permeate the skull diploe but, at specific locations, directly pierce through
the skull bone. As in the case of nerve foramina and surgical skull holes (Chauveau et al., 2004; Lanfer et al., 2012a; van den Broek et al., 1998; Heasman et
al., 2002; Bénar and Gotman,
2002; Li et al., 2007; Oostenveld and Oostendorp, 2002; Sparkes et al., 2009; Thevenet et al., 1992; Vanrumste et al., 2000), these direct connections (foramina) between
brain and head surface may significantly influence the forward and inverse
propagation of electrical fields. However, the impact of these skull foramina due to
blood vessels on VCHMs has thus far not been addressed. (ii) The conductivities
previously used to simulate blood vessels were quite high (0.417–1.25 S/m)
(Haueisen et al., 1997) and while these
values appear appropriate for blood per se, they may not be
adequate for the blood vessel system as a whole, as vessels also include the
surrounding layer of endothelium. This endothelium, among other tasks, serves as a
diffusion barrier with low electrical conductivity, preventing substances from
freely entering and leaving the blood stream. The importance of taking into account
the low electrical conductivity of blood vessel walls has recently been demonstrated
for electrocardiogram (ECG) modeling (Stinstra et
al., 2005a, 2005b). Although
direct measurements comparing vessel wall resistance in the brain with that in the
rest of the body are missing to our knowledge, resistance of the former may be even
more pronounced, as the endothelium there forms the brain–blood barrier
(BBB) with a high number of tight junctions between endothelial cells (Daneman, 2012), which should further decrease
electrical conductivity. Thus, the vessel-wall-related effects previously described
in ECG modeling (Stinstra et al., 2005a,
2005b) may be even more important for the
blood vessels supplying the brain.To investigate the role of blood vessels in volume conductor modeling, we
needed to create a detailed reconstruction of the cerebral blood vessels. 7 T MRI
can detect blood vessels with a particularly high contrast-to-noise ratio (CNR)
(Maderwald et al., 2008) not achieved at
lower field strengths. We therefore built a VCHM including a detailed blood vessel
compartment based on submillimeter 7 T anatomical sequences. We assessed the
modeling errors induced by neglecting blood vessels (arteries and
intraosseous/emissary veins) by comparisons with the well-established effect of
neglecting CSF, as well as with the effect of neglecting the dura. In addition, the
feasibility of using 7 T MRI data to build a submillimeter VCHM needed to model
near-microscopic blood vessels had not been investigated thus far. We therefore
implemented this new approach to create the first submillimeter 7 T-based VCHM and
solve it using a Finite Element Method (FEM) transfer matrix approach to minimize
computational load while maintaining minimal numerical errors.The present paper provides a detailed description of the methods used to
create our submillimeter FEM model based on 7 T MRI data, including the extraction
of the blood vessels using spatial filtering methods, describes the computational
requirements for whole-head submillimeter FEM modeling, and presents the forward and
inverse modeling results on the role of blood vessels in high-resolution volume
conductor head modeling of EEG.
Methods
7 T MRI data acquisition and pre-processing
Whole-head 3-D Magnetization Prepared Rapid Gradient Echo (MPRAGE,
T1-weighted) and 3-D Gradient Echo (GE, PD-weighted) sequences of one male
subject (age: 27, right-handed, no history of neuro-psychiatric disease) were
acquired on a Magnetom 7 T whole body MRI system (Siemens, Germany, Erlangen) at
a 0.6-mm isotropic resolution (Fig. 1a,b).
Acquisition parameters are summarized in Table
1.
Fig. 1
7 T structural MRI data and segmentation. (a) 7 T T1 MPRAGE MRI data at 0.6-mm
isotropic resolution used to derive the volume conductor head model. Arteries
are, for example, visible as bright tubular structures in the insular region
(white box). Note that the dataset was acquired without any contrast agent. (b)
3 T T1 MPRAGE dataset obtained in the same subject (see Derix et al., 2014; Lüsebrink et al., 2013 for acquisition parameters). Arteries
in the same region (white box) are not clearly visible. (c) Axial slice through
the VCHM derived from the 7 T data by tissue segmentation. The white box again
highlights the insular region as in (a) and (b). Segmented blood vessels are
shown in red. Note that neither the hematopoetic nor the fatty bone marrow was
included in the segmentation (see Methods section). (d) 3-D visualization of
intracranial and intraosseous blood vessels (cf. Fig. 2 for a 3-D for visualization of extraosseous vessels); the
black arrow indicates an example of an intraosseous vein.
Table 1
7 T MRI acquisition parameters.
Sequence
TR
TI
TE
Flip angle
Bandwidth
Field of view
Voxel size
MPRAGE
2500 ms
1050 ms
2.87 ms
5°
150 Hz/pixel
230.4 mm × 230.4 mm
0.6 mm × 0.6 mm × 0.6 mm
GE
1630 ms
–
2.87 ms
5°
150 Hz/pixel
230.4 mm × 230.4 mm
0.6 mm × 0.6 mm × 0.6 mm
The volumes were co-registered using SPM8 (freely available at http://www.fil.ion.ucl.ac.uk/spm/) with default parameters and
T1 as reference. Additionally, a third dataset with a more homogenous brain was
created by dividing the T1 images by the PD images (Van de Moortele et al., 2009). The T1/PD data was
used for skull stripping and brain segmentation (cf. Supplementary Methods for a
detailed description of the segmentation procedure).
Segmentation of blood vessels
To segment cranial blood vessels (intracranial, intraosseous, and
extracranial), we utilized a Frangi vesselness filter (Kroon, 2009). This filter is designed to enhance
tubular structures, indicated by the eigenvalues of the Hessian of the image
data at multiple spatial scales (Frangi et al.,
1998; Manniesing et al.,
2006). In our hands, this filter proved well-suited for segmenting
arteries and intraosseous/emissary veins, but not as successful in detecting
draining veins. This could be due to the draining veins’ geometry and
lower contrast, because of slower blood flow compared to the arteries.
Throughout the manuscript, we will use the term “blood vessels”
when addressing all segmented vessels, and
“arteries” or “veins” otherwise. Blood vessels
were segmented from the Frangi-filtered volumes with an in-house regional growth
algorithm (see Supplementary
Methods for further details). Intraosseous vessels, including veins
piercing through the skull via foramina, were identified by computing the
intersection between the blood-vessel and skull compartments. Results were
manually inspected and compared with anatomy atlases (Benninghoff, 1993; Netter, 1987; Nowinski et al.,
2011) to ensure that only blood vessels were segmented. An axial
slice as well as a 3-D axial cut through the final head model segmentation are
shown in Fig. 1(c) & (d), respectively.
Fig. 2 shows an overview of all
segmented blood vessels, including major cerebral arteries and their
ramifications (Benninghoff, 1993; Netter, 1987; Nowinski et al., 2011)
Fig. 2
Blood vessels extracted from 7 T MRI by Frangi vesselness filtering and regional
growth segmentation. The following cerebral blood vessels are indicated by
numbers: (1) internal carotid arteries, (2) vertebral arteries, (3) basilar
artery, (4) posterior arteries, (5) medial arteries, (6) anterior artery. (A)
Part of the carotid artery above the foramen lacerum. Draining veins, due to the
slow flow of their blood, produced insufficient signal for accurate segmentation
and are thus not included. For orientation, the inset shows the outer surface of
the head model from the same viewing angle as for the blood vessels in the main
figure.
Volume conductor head models
To quantify and compare the model errors induced by ignoring blood
vessels, the CSF, and the dura, we created one blood-vessel-free model, three
models including blood vessel, one CSF-free model and two dura-free models
(Fig. 3).
Fig. 3
Volume conductor head models investigated. No-blood-vessel-model: Model without
any blood vessels, all other segmented tissues are included. Blood vessel model:
As before, but with blood vessels. This model was used with three different
blood vessel conductivities (see Methods section). No-CSF-model: As the
no-blood-vessel-model, but with CSF replaced by gray matter. Dura-as-bone-model:
As the no-blood-vessel-model, but with dura replaced by compact bone.
Dura-as-CSF-model: As the no-blood-vessel-model, but with dura replaced by CSF.
Color-coding as in Fig. 1. Note that the
holes in the rendering of the no-CSF-model are due to the very thin 3D slice
used, combined with the geometry-adapted mesh described below. These holes are
not present in the full volume model.
The blood-vessel-free model was the model as described above, but
without the blood vessels, which were replaced by the surrounding tissue types,
i.e., soft tissue, fat, bone, dura, CSF, GM and WM, depending on the vessel
location. We shall refer to this model as the no-blood-vessel-model.In the blood vessel model, all blood vessels derived from the imaging
data as described in the preceding sections were implemented as one blood vessel
compartment. For volume conductor modeling, a conductivity value needs to be
assigned to each volume conductor model compartment. In contrast to other tissue
types such as skin, bone, or gray matter, there are no conductivity values in
the literature for the total conductivity of cerebral blood vessels, i.e.,
including both vessel walls and blood-filled vessel lumen. As it is not yet
possible to treat vessel walls and lumina separately, we modeled them as one
compartment and set the compound conductivity of this compartment to cover the
range of possible scenarios described in the Introduction. Because it is highly
unlikely that blood vessels as a whole could have a conductivity (σ)
higher than that of blood alone (Haueisen et
al., 1997), we used the latter as our upper limit in the
high-σ-model. Similarly, it is highly unlikely that the combination of
blood vessel walls (endothelium) and BBB would produce a conductivity lower than
that of compact bone. Therefore, we used compact bone conductivity (Haueisen et al., 1995) as a lower extreme
in the low-σ-model. Because the conductivity of cardiac blood vessel
endothelium is known (Stinstra et al.,
2005a, 2005b), we used this
conductivity for our intermediate-σ-model.Several previous studies have demonstrated the importance of the CSF on
volume conduction. It is well established that neglecting the CSF compartment
induces severe modeling errors. To directly compare model improvement by
including CSF with model improvement by including blood vessels, we generated a
no-CSF-model by replacing CSF by gray matter in the no-blood-vessel-model. To
also compare blood-vessel-related effects to those related to the dura, we
replaced the dura of the no-blood-vessel-model by compact bone in the
dura-as-bone-model. Finally, as an alternative scenario of dura-related model
errors, the dura was replaced by CSF in the dura-as-CSF-model. Both dura models
are included because, in our experience, the dura may be misclassified as either
bone or CSF, depending on which MRI-weighting the segmentation is based on.
Fig. 3 shows axial slices through the
different models investigated.
FEM methods
FEM forward calculations were computed with SimBio-NeuroFEM (SimBio Development Group, 2012) using the
Saint-Venant direct approach (Buchner et al.,
1997; Wolters et al., 2007;
Vorwerk et al., 2012) based on
geometry-adapted cubic meshes (Hartmann et al.,
2010) (cf. Supplementary Methods for details), which improve the precision of
the computed potentials by reducing the error due to unsmooth transition edges
(Wolters et al., 2007). To achieve
good RAM efficiency, we used a conjugate gradient solver with incomplete
Cholesky preconditioning (IC(0)-CG) (Lew et al.,
2009). To maximize the accuracy of our model, forward solutions were
calculated with a residual error in the order of 10−11. All
models comprised the same 17,606,835 nodes and 17,349,004 elements with an
isotropic resolution of 0.6 mm. To reduce simulation time, a transfer matrix for
329 EEG channel was calculated for each model (Wolters et al., 2004). The positions of the 329 electrodes were
defined according to the 10-5 system (Oostenveld
and Praamstra, 2001) using the MATLAB script kindly provided by Giacometti et al. (2014) on their website.
Conductivity values of the different tissue compartments are listed in Table 2.
Table 2
Overview of algorithms and MRI data used for the segmentation of each model
compartment. Additionally, the conductivities used for FEM simulations and
references for these values are given.
For building the models, we used a workstation with 4 × 2.8 GHz
cores central processing units (CPU) and 16 GB of random access memory (RAM)
under Linux. For simulations, three different systems were used: the same as for
building the models, one with 16 × 3.1 GHz cores and 256 GB RAM and one
with 120 × 2.8 GHz cores and 3 TB RAM, the latter two used to run
multiple simulations in parallel.
Placement of sources
For forward EEG simulations, one St. Venant dipole (Wolters et al., 2007) was placed at the center of
every gray matter mesh element of the full model (with blood and CSF
compartments). The St. Venant direct approach has a high computational
efficiency when used in combination with a FEM transfer matrix (Wolters et al., 2004). To fulfill the St. Venant
condition (Lanfer et al., 2012a; Vorwerk et al., 2014), all dipoles
neighboring non-gray matter elements were discarded using a parallelized version
of the sb_check_sources function provided by FieldTrip (Oostenveld et al., 2011), resulting in 2,229,036
remaining dipoles. Inverse localization was performed on a St.
Venant-conditionfulfilling 1.2-mm isotropic grid (278,565 dipoles). The dipoles
were oriented normally to the local gray matter surface (see Supplementary Methods for more
details).Because the dipolar model of brain activity is best used when evaluating
the effect of spatially smooth structures, like dura and CSF, and blood vessels
are heterogeneously distributed within the brain, an extended source model could
better approximate the effects to expect in vivo. Therefore we
generated a second source space where the activity of each entry was taken as
the sum of all dipoles within a cortical area of approx. 6 cm2 which
is often assumed to be the area of cortex required to be active to generate
scalp-visible effects (Cooper et al.,
1965).
Error measures
To quantify and compare the effects of ignoring blood vessels, CSF and
dura, we calculated three error measures commonly used in the modeling
literature. In the following, “reference model” always refers to
the more detailed model of a tested pair and the “test model” to
the less detailed model, which is responsible for the investigated error. Seven
model pairs were tested, which were the no-blood-vessel-model paired with each
other model.The first error measure investigated was the relative difference measure
(Lew et al., 2009; Meijs et al., 1989) (RDM), defined aswhere n is the number of
electrodes, and ref and
test are the voltages of all sources at the
ith electrode in the reference model and the test model,
respectively. The RDM is used to quantify forward errors and was calculated for
all 2,229,036 cortical sources of each source model. In some publications the
subtraction of the L2 norms is inverted (test-ref instead of
ref-test). From a mathematical point of view this makes no difference and is
irrelevant for comparability.The second error measure was the goal function scan localization error
(Mosher et al., 1992), defined aswhere
GfPos(test) is the position in the source
space of the test models where the goal function scan is minimal for the
ith source, Pos(ref) is
the position in the source space of the reference source and
GfError is the Euclidian distance between
Pos(ref) and
GfPos(test), also known as the
localization error, test is the voltages at all
electrodes of the ith source,
L,· is the leadfield matrix
of the reference model for the ith source and all electrodes,
and n is the number of electrodes. The localization error is
used to quantify the inverse error and was calculated for a 1.2-mm grid
comprising 278,565 sources, again for both source models. The number of sources
was reduced for this error measure because of its high computational load. As
sources were reconstructed using identical grids perfect source localization
(zero localization error) is possible, making our estimation of the inverse
error conservative. Because sources were always reconstructed in a test vs.
reference model setting, implying that reconstruction was always performed in a
model other than the one used for forward simulation, this is not an inverse
crime (Kaipio and Somersalo, 2007).We also calculated the logarithmic magnitude error (lnMAG), defined
aswhere test and
ref are the voltages of all sources at
electrode n for the test model and the reference model, respectively. This error
measure did not provide any additional insights to the other two error measures
and was therefore later omitted (Lanfer et al.,
2012a).RDM, localization errors and lnMAG were computed using in-house Matlab
scripts (The MathWorks Inc., Natick, MA, USA). Because the RDM is bounded
between 0 and 2, it can be converted into a percentage by dividing by 2 and
multiplying by 100. For more information regarding these error measures, we
refer to Lew et al. (2009), Meijs et al. (1989), and Mosher et al. (1992)).
Analysis of the impact of local blood vessel density on errors
To quantify the influence of the local blood vessel density on errors, a
multi-scale rank correlation analysis was performed. This analysis was designed
to answer the question: blood vessels at which spatial scale around a source are
relevant for the observed errors? To this end, the errors observed at all source
positions were correlated with the local blood vessel density at these
positions, both for the forward and inverse error measures, using
Spearman’s rho (Best and Roberts,
1975). The local blood vessel density was obtained from spherical
kernels around each position, their diameters ranging between 0 mm and 100 mm
(multiples of the model resolution, 0.6 mm). Local blood vessel density was
expressed as the ratio of blood vessel elements within the kernel to all
elements within the kernel. Local blood vessel density was chosen as measure
because of its invariance against blood vessel size (discussed in Impact of
source size section).
Results
In the present study, for the first time, a FEM VCHM with an isotropic
submillimeter resolution including a detailed blood vessel compartment and skull
foramina was used for forward and inverse modeling (Figs. 1(c), (d), 2 & 3). In the following, we will present the forward
and inverse simulation results and also describe the computational requirements of
submillimeter FEM modeling.
Effect of blood vessels
To understand the role of blood vessels in volume conductor head
modeling, three scenarios with different blood vessel conductivities were
investigated. In the first one, the high-σ-model, blood vessels were
attributed the conductivity of blood (Haueisen
et al., 1997). In the second scenario, the
intermediate-σ-model, the conductivity of the cardiac endothelium was
used (Stinstra et al., 2005a). In the
third case, the low-σ-model, blood vessels were modeled with
conductivity of bone as the lower extreme. This wide range of conductivities was
used to ensure that effects induced by the real bulk conductivity of cerebral
blood vessels, which can be expected to be somewhere in this spectrum, will be
accounted for. To ensure that we did not overestimate the effects of blood
vessels due to the use of single dipolar sources we also calculated the results
for an extended source model (cf. Methods section). Results obtained with
dipolar and extended sources were mostly very similar regarding the conclusions
of this paper. The reported results thus refer to both source models if not
otherwise stated.The simulations produced one EEG topography for each model and dipole.
The EEG topographies resulting from selected dipoles (with the 100th strongest
RDM) for all models are shown in Fig. 4.
The change in topographies induced by introducing blood vessels and varying
their conductivity are quite noticeable for the presented example of the
topographies with the 100th strongest RDM error for each model. As can be seen,
blood vessel-related topography changes become visible to the bare eye above an
RDM of approx. 0.2. Following Lanfer and colleagues, we consider errors with an
RDM value >= 0.1 and/or a mislocalization >= 5 mm as
non-negligible (Lanfer et al.,
2012a).
Fig. 4
Effect of the different head models on forward-calculated EEG topographies. (a)
Location and orientation of the selected example dipoles in sagittal and coronal
views (anterior point of view) indicated by cyan cones. Red and yellow:
intracranial and intraosseous vessels, respectively. (b–h) Forward
calculated EEG maps resulting from the dipoles shown in (a) and obtained with
the no-blood-vessel-model (b; with overlaid electrode layout), with the
high-σ-model (c), intermediate-σ-model (d), low-σ-model
(e), no-CSF-model (f), dura-as-CSF-model (g), and dura-as-bone-model (h). RDM
errors of the EEG maps relative to the no-blood-vessel model are indicated in
the upper left corner above each EEG map. In each column, the model used to
select the example dipole is highlighted by a light-gray box. In each case, the
dipole producing the 100th strongest RDM error with the indicated model was
selected.
RDM and goal function scan localization errors were computed against a
model without any blood vessels (Figs.
5–8). Maximal error,
mean error, the proportion of affected sources and the 5th, 50th and 95th
percentiles of the error distributions are summarized in Table 3.
Fig. 5
Spatial distribution of non-negligible errors induced by ignoring blood vessels:
RDM errors of dipolar sources. Color and size of spheres represent RDM error at
source positions. Transparent gray and yellow: brain and skull blood vessels,
respectively Note the non-negligibly affected sources along small vessels (e.g.,
black box). As draining veins, such as the sagittal sinus, were not included in
our model, there are no corresponding errors. (a) Results obtained with the
high-σ-model, (b) the intermediate-σ-model, and (c) the
low-σ-model, all in coronal and sagittal views. Black arrows: errors due
to skull foramina and intraosseous vessels.
Fig. 8
Spatial distribution of non-negligible errors induced by ignoring blood vessels:
localization errors of extended sources. As in the case of forward errors (Fig. 7), non-negligibly affected sources
along small blood vessels were reduced (e.g., black box). In vessel-rich
regions, localization errors were magnified (large red cones, cf. Fig. 6). Conventions as in Fig. 6.
Table 3
RDM and goal function scan localization error. Overview of all test models of
this paper, together with selected models of Lanfer et al. (2012a) and Güllmar et al. (2010) (details in Blood-vessel-related
errors in relation to previously described modeling errors section).
Model
RDM
Localization error
Max (unitless)
Mean (unitless)
>=0.1
Max (mm)
Mean (mm)
>=5 mm
This paper
Dipolar sources
High-σ
1.354
0.018
0.851%
23.546
0.148
0.676%
Intermediate-σ
1.622
0.017
2.100%
29.686
0.242
1.322%
Low-σ
1.651
0.017
2.316%
29.686
0.258
1.436%
No-CSF
1.567
0.148
61.331%
35.211
3.498
27.605%
Dura-as-bone
1.91
0.107
34.244%
49.623
2.715
21.859%
Dura-as-CSF
1.66
0.093
32.872%
35.638
2.748
23.026%
Extended sources
High-σ
1.199
0.018
0.72%
37.355
0.152
0.495%
Intermediate-σ
1.661
0.017
1.617%
61.948
0.265
0.944%
Low-σ
1.718
0.017
1.83%
61.948
0.278
1.017%
No-CSF
1.974
0.173
68.365%
68.442
3.398
19.045%
Dura-as-bone
1.753
0.114
39.722%
57.161
2.204
13.507%
Dura-as-CSF
1.107
0.092
33.019%
59.494
2.539
15.226%
Lanfer et al. (2012a)
Segmentation defects
10 mm skull hole (1c)
0.889
0.016
1.905%
9.314
1.073
0.343%
4 mm constant skull & scalp (6a)
1.399
0.12
49.403%
27.1431
5.738
45.220%
6 mm constant skull & scalp (6b)
1.399
0.091
29.236%
28.227
3.748
23.824%
Model
95th percentile
50th percentile
5th percentile
This paper
Dipolar sources
High-σ
0.042
0.013
0.006
Intermediate-σ
0.06
0.008
0.003
Low-σ
0.063
0.008
0.003
No-CSF
0.342
0.123
0.037
Dura-as-bone
0.272
0.077
0.033
Dura-as-CSF
0.186
0.084
0.037
Extended sources
High-σ
0.039
0.013
0.006
Intermediate-σ
0.061
0.008
0.003
Low-σ
0.063
0.008
0.003
No-CSF
0.407
0.142
0.040
Dura-as-bone
0.288
0.084
0.034
Dura-as-CSF
0.171
0.085
0.039
Güllmar et al. (2010)
Anisotropic transversal:lateral
ratios
1:2
0.064
0.018
0.004
1:10
0.265
0.071
0.016
1:100
0.643
0.191
0.050
Forward and inverse errors of both source models showed a similar
general picture. With the high-σ-model, non-negligible (see above)
errors were mainly located directly adjacent to points with blood vessels either
passing through or within the skull (emissary or intraosseous vessels,
respectively) (Figs. 5(a) & 7(a)), namely 5 vessel-related skull foramina
and 3 intraosseous veins. The foramina were the parietal emissary foramen, the
paired carotid canals, parts of the paired foramen lacerum, parts of the paired
foramen spinosum and two symmetrical foramina located above the anterior part of
the Sylvian fissure (Netter, 1987). The
paired intraosseous veins were the venae diploicae frontalis,
temporalis posterior and occipitalis
(Netter, 1987). The segmentation of
the former vein also included the entry and exit parts of the canales
diploici (Benninghoff, 1993;
Netter, 1987).
Fig. 7
Spatial distribution of non-negligible errors induced by ignoring blood vessels:
RDM errors of extended sources. Compared with the results obtained with the
dipolar sources, there were fewer non-negligibly affected sources along small
blood vessels (e.g., black box), while errors in vessel-rich areas were not
diminished. Conventions as in Fig. 5.
With the high-σ-model, non-negligible errors were also found
close to the major brain arteries (anterior, lateral and posterior arteries) and
their branches (Figs. 5(a) & 7(a)). For the intermediate-σ-model,
some non-negligible errors were still found close to emissary or intraosseous
vessels, but errors mainly clustered around major and minor arteries (Figs. 5(b) & 7(b)). Finally, for the low-σ-model,
nonnegligible errors were no longer found close to emissary or intraosseous
vessels. Instead, errors now clustered strongly around major and minor arteries
(Figs. 5(c) & 7(c)).With both source models (dipolar and extended sources), the overall
strongest and most widespread errors were observed for the
region of the carotid arteries. An example of the EEG topography differences for
a dipole in this region and with the different models investigated is shown in
Fig. 4, first column. Other areas with
dense vasculature and pronounced errors included the anterior cingulate, the
insula, and the medial temporal lobe (Figs.
4–8).
Impact of local blood vessel density on errors
The spatial error distributions as shown in Figs. 5–8
indicated a close spatial relation of local vessel density and error magnitudes
for the intermediate- and low-σ-vessel-models, while the spatial
distribution of errors in the high-σ model appeared to be dictated by
the position of vessels penetrating the skull. To quantify these relations, we
performed a correlation analysis across multiple spatial scales. This confirmed
the visual impression of a strong relationship between local blood vessel
density and error measures (cf. Fig. 9) for
both low- and intermediate-σ-models. For these models, correlations
became maximal with kernels of 20- to 30-mm diameters for forward and inverse
errors, respectively, indicating a critical spatial scale with the highest
relevance of local blood vessel density to VCHM modeling (if the low-to-medium
conductivity assumption is correct). Expectedly, errors obtained in the
high-σ-scenario did not show a strong correlation of errors with local
blood vessel density.
Fig. 9
Rank correlation between error measures and blood vessel density at multiple
spatial scales. The diameter of the spherical kernels used to determine the
local blood vessel density was varied between 0 and 100 mm. Note the calculation
of local blood vessel density included vessels of all sizes; thus high values
may indicate both, the presence of large vessels, or local clusters of many
small vessels. (a) Results for forward errors, and (b) inverse errors.
Effect of CSF and dura on modeling errors
To put vessel-related errors in relation to other model errors, we
examined errors due to ignoring the CSF and dura. Forward-calculated EEG maps
reflecting errors made by ignoring the CSF (results for dipoles with the
100th strongest RDM) are shown in Fig. 4(f). The changes in topographies induced by replacing CSF by
gray matter were, as expected, pronounced (Table
3). Overall, forward and inverse errors showed similar distributions.
Non-negligible (>=5 mm or >=0.1 RDM) errors were found
throughout the source spaces, with clusters of higher values, often on gyral
crowns. Similar results have been reported by Lanfer and colleagues using
dipolar sources (Lanfer et al., 2012b).
The high values and broad spatial distribution of modeling errors are in
accordance with the literature (Ramon et al.,
2006; Haueisen et al., 1997;
Slutzky et al., 2010; Ramon et al., 2004; van den Broek et al., 1998; Vorwerk
et al., 2014; Bangera et al.,
2010; Bénar and Gotman,
2002; Lanfer et al., 2012b;
Rice et al., 2013; Vanrumste et al., 2000; Wendel et al., 2008).Forward-calculated EEG results reflecting errors made by ignoring the
dura (replaced by compact bone and CSF, respectively) are summarized in Table 3 and shown in Fig. 4 (g) & (h). Ramon et al. (2014) and Ramon
(2012) have reported lower forward errors (0.057 mean RDM) when
replacing the dura with CSF using dipolar sources. To the best of our knowledge,
no investigation considering replacing the dura with compact bone exists for
comparison, although such segmentation errors may occur.
Computational requirements of submillimeter head modeling
The main criteria for the computational feasibility of forward and
inverse EEG modeling are the computation time and the amount of memory needed.
With the current implementation (cf. FEM methods section), computing one row of
the transfer matrix (Wolters et al.,
2004), corresponding to one EEG electrode, took approx. 24 min.
Computation of the whole transfer matrix (a matrix with approx. 329 × 17
Mio. entries) for all 329 electrodes thus lasted 133.5 ± 3.8 h (mean
± std). After having calculated the transfer matrix (only once per model
and sensor-configuration), one forward simulation could then be performed in
just approx. 120 ms per dipole. For all 2,229,036 dipoles, the forward
simulation thus lasted 74.5 ± 0.6 h. Times are given for a solver
residual error in the range of 10−11 on a 2.8 GHz CPU and may
vary according to the geometrical complexity of the models. No more than 30.5 GB
of RAM were required for any operation.
Discussion
In the present study, we investigated the role of a detailed reconstruction
of blood vessels in a submillimeter VCHM. This was made possible by the use of
anatomical submillimeter 7 T MRI data. Before such data became available, specific
diffusion weighted sequences and contrast agents had to be used to create
angiograms. Presumably for this reason, the effect of blood vessels on forward and
inverse modeling has, up to now, never been investigated in detail. In the
following, we discuss the results of the different conductivity scenarios and the
modeling errors induced by ignoring the blood vessels located within the skull.
Furthermore, we compare our simulation results to the literature and make
suggestions on how to improve computational speed. Finally, we discuss limitations
and perspectives of our work.
Errors with different blood vessel conductivity
Our findings, as summarized in Table
3, showed similar mean and percentile errors irrespective of the
conductivity σ (high, intermediate, low) assumed for the blood vessel
compartment, and also irrespective of the type of source model (dipole,
extended). The maximal inverse errors, however, were considerably larger with
the extended source model than with the dipoles (discussed in Impact of source
size section). There also were more strongly affected inverse localizations (as
indicated by the large red cones in Fig. 8)
in the high- than in the intermediate- and low-σ simulations of extended
sources. The conductivity of blood vessels, which we varied in our simulations
over two orders of magnitude, appeared to only marginally influence the strength
of the dipolar errors, while the extended source errors were stronger for both
low- and intermediate-σ-model. The percentage of non-negligibly affected
sources (RDM >= 0.1, localization error >= 5 mm), however,
showed much stronger variations. More than twice as many sources were
non-negligibly affected in the intermediate-and low-σ-models than in the
high-σ-model (Table 3). This can
be explained by the high deviation of the intermediate and low conductivities
from those of the surrounding brain tissue, which was not the case in the high
conductivity scenario.The error measure results summarized in Figs. 5–8 showed two
distinct spatial error patterns: (i) Errors clustering around cerebral arteries
and (ii) errors clustering in the vicinity of skull foramina and intraosseous
vessels. The latter error type was mainly present in the results obtained with
the high-σ-model, while the former type errors were present in all 3
cases (all σ-models), but much stronger in results obtained with both
intermediate- and low-σ-models, reflected in the different percentages
of affected sources as discussed above.Error clusters around arteries were widely distributed, affected the
medial temporal lobe and followed the paths of the three major brain arteries:
the anterior cerebral artery, the middle cerebral artery and the posterior
cerebral artery. As the arteries branched into smaller vessels, the errors
became smaller until they vanished completely, which happened earlier (at larger
vessel diameters) for extended than for dipolar sources (Figs. 5–8). The cingulate and insular cortices were strongly affected because of
their dense vasculature. Because the draining veins and superficial cortical
vessels were not included in the model (cf. Limitations and further perspectives
section), the outer surface of the cortex was less affected, with errors mainly
at the frontal pole and at the intersection of parietal, occipital and temporal
cortices (TPO area). Including these missing vessels can be expected to further
increase the number of affected areas and could also induce interesting edge and
tunneling effects as some of them pass through the CSF (with high conductivity)
and some through the dura (with low conductivity).Errors clustering in the vicinity of blood vessel skull foramina and
intraosseous vessels (black arrows in Fig. 5 (a)
& (b)) were most pronounced in the region in the vicinity of the
carotid canal. Errors here may affect source reconstruction in the medial and
basal temporal lobe, which is of interest in the context of mesial-temporal
epilepsy (Waberski et al., 2000; Jung et al., 2009; Merlet et al., 1996; Assaf and Ebersole, 1997; Merlet et
al., 1998; Fernández-Torre et
al., 1999a; Fernández-Torre
et al., 1999b; Aydin et al.,
2015; Aydin et al., 2014). The
remaining blood vessel skull foramina and intraosseous veins were in most cases
too small (Lanfer et al., 2012a) to
induce strong and widespread errors, despite being located between sources and
electrodes (Lanfer et al., 2012b).
Nevertheless, most of these produced non-negligible errors (RDM >=
0.1 and localization errors >= 5 mm (Lanfer et al., 2012a)), although in a highly localized manner.Results from spatial multi-scaled correlation of errors with local blood
vessel density (Fig. 9) also pointed to the
different mechanisms underlying the error generation in the
high-σ-vessel-model compared with the low- and intermediate-σ
models. Blood vessel densities at the scale of 20 to 30 mm, i.e. still mostly
within the skull, correlated best with forward and inverse errors of both low-
and intermediate-σ-models. Forward and inverse errors related to the
high-σ-model were, however, not strongly correlated with local blood
vessel density, but rather appeared dominated by errors due to vessels piercing
the skull (Figs. 5–8), highlighting the different error mechanisms with
different vessel conductivities and a need for experimental clarification of
this issue (see Conclusions & outlook section).
Blood-vessel-related errors in relation to previously described modeling
errors
To relate our findings to previously investigated modeling errors, we
compared our results obtained with the no-CSF-model, the dura-as-bone/CSF-models
and reports by two recent publications (Lanfer
et al., 2012a; Güllmar et
al., 2010) in which detailed error measures such as RDM and
localization error were given.
CSF, dura and skull
Ignoring the CSF caused similar maximal errors as ignoring vessels
(Table 3), but a larger mean error
and a higher proportion of affected sources. The critical positioning of the CSF
between sources and electrodes together with its large extend is the main reason
why not including it creates such strong errors (Lanfer et al., 2012b), as confirmed by our results and in line with
a large number of previous modeling studies (Ramon et al., 2006; Haueisen et al.,
1997; Slutzky et al., 2010;
Ramon et al., 2004; van den Broek et al., 1998; Vorwerk et al., 2014; Bangera et al., 2010; Bénar
and Gotman, 2002; Lanfer et al.,
2012b; Rice et al., 2013;
Vanrumste et al., 2000; Wendel et al., 2008) and recent
experimental findings (Rice et al.,
2013).Replacing the dura by compact bone or CSF caused maximal model errors
quite similar to those due to blood vessels (Table 3) but again with a larger spatial extent, probably for
similar reasons as discussed for the case of the CSF above. Our present results
confirm that the dura plays a major role VCHM accuracy (Slutzky et al., 2010; Ramon et al., 2014; Ramon,
2012) and that the inclusion of the dura is nearly as important as
that of the CSF.In summary, on the whole-brain scale, CSF and dura are more important
for VCHM accuracy than blood vessels. On the other hand, local errors due to
ignoring blood vessels were on par with those due to ignoring CSF or dura (Table 3; Fig.
5) indicating that for critical regions with dense vasculature and/or
close to vessels piercing the skull, source localization directed at these areas
may profit from including blood vessels as much as from modeling the CSF or
dura.Inaccurate modeling of skull geometry has also been repeatedly reported
to be a common source of model errors (Dannhauer
et al., 2011; Ramon et al.,
2004; Chauveau et al., 2004;
Lanfer et al., 2012a; Anwander et al., 2002; Ary et al., 1981; Cuffin,
1993; van den Broek et al.,
1998; Vorwerk et al., 2014).
Lanfer et al. (2012a) published a
thorough investigation of the influence of skull segmentation inaccuracies on
EEG forward and inverse problems, including effects due to skull holes, under-
or overestimating skull thickness, or neglecting skull sinuses (cf. Table 3). Among these errors, those caused
by ignoring a skull hole with a 10-mm diameter were most similarly to the errors
that we observed in relation to cerebral blood vessels. Lanfer and colleagues
recommend that skull hole larger than 2 mm should be included in EEG head
models.
Anisotropy
Another widely discussed source of errors in head modeling are
anisotropic conductivities. Several authors (Anwander et al., 2002; Vorwerk et
al., 2014; Bangera et al.,
2010; Haueisen et al., 2002; Güllmar et al., 2010; Wolters et al., 2006; Hallez et al., 2005, 2008, 2009; Rullmann et al., 2009; Wolters, 2003) have described the influence of white
matter anisotropy in this context. The study by Güllmar et al. (2010) is especially detailed and is
therefore used here to compare our results with respect to the forward error
measures. Güllmar and colleagues used a different inverse approach than
Lanfer et al. (2012a) and we did and
to the best of our knowledge no study of anisotropy with a comparable inverse
error metric exists.The 95th and 50th percentiles of the RDM values, closest to ours,
obtained by Güllmar and colleagues with anisotropic models are listed in
Table 3. When comparing the RDM
values, it becomes apparent that the effect of including blood vessels is
comparable to the effects due to a 1:2 transversal to longitudinal anisotropy
ratio, which may be a realistic value as suggested by a number of recent studies
(Bangera et al., 2010; Güllmar et al., 2010; Hallez et al., 2008; Wolters, 2003). For example, Bangera
et al. (2010) compared simulations of anisotropic models with, among
others, ratios between 1:2 to 1:10 with in-vivo intracortical
electrical stimulation measurements in epilepsypatients. They could
conclusively show that the 1:10 ratio fitted worst to the data for all four
measured patients. On average, the best fitting ratio was 1:2. Thus, ignoring
blood vessels may cause similar forward errors than ignoring white matter
anisotropy, at least with a presumably realistic transversal to longitudinal
anisotropy ratio.It is, however, important to keep in mind that our forward and inverse
errors were probably underestimated as the majority of superficial cortical
vessels as well as the veins could not be included in our model (cf. Limitations
and further perspectives section). Furthermore, because of the use of identical
source grids for forward and inverse modeling, our localization errors are
conservative (see Methods section). We can, therefore, conclude that, regardless
of the conductivity and of the source model used, blood vessels cause, on a
local scale, errors that are comparable with errors produced by ignoring
anisotropies, unrealistic modeling of the skull, and ignoring the CSF or the
dura.
Impact of source size
We compared modeling results with dipolar (point-like) and extended
(surface of approx. 6 cm2) source models, respectively. Results
obtained with these source sizes both support our general conclusions regarding
the importance of blood vessels in volume conductor head modeling of EEG.
However, there were also more subtle differences in the error patterns,
providing interesting insights on how source model size and VCHM structures
interact and shape forward and inverse solutions.With all other parameters kept constant, one might expect that a
structure would have maximal local effect onto forward and inverse errors onto
sources with a matching spatial extend, thus interpreting the volume conductor
as a spatial filter according to the principle of the matched filter theorem
(Rosenfeld and Kak, 1982). For
example, in our simulations, this would mean that dipolar sources, which have
close to no spatial extent, would be expected to have maximal effect in the
vicinity of small structures, like small blood vessels. Larger extended sources
would be expected to have maximal effect when combined with larger structures,
like large vessels, or other large-scale spatial smooth structures as the CSF or
dura compartment. This is indeed what we observed from the percentage of
non-negligible forward errors (Table 3).
A similar effect was also observed in the spatial distribution of errors
throughout the volume conductor. As highlighted by the black boxes in Figs. 5–8, non-negligible errors due to dipolar sources aligned along small
blood vessels and mostly disappeared when switching to extended sources. In
contrast, non-negligible errors of the large sources close to large blood
vessels were enhanced. Our findings point towards complex interactions between
spatial properties of source and volume conductor models, which have received
little attention so far but may be practically important, as not all brain
activation may be well approximated by dipolar sources and may rather involve a
wide range of different spatial scales (Ball et
al., 2012).We showed that FEM modeling based on submillimeter 7 T MRI data with
more than 17 Mio. voxels is possible with current workstations and using
Open-Source software (cf. FEM methods section). Improving the speed and memory
usage of FEM computations is an important goal in FEM research (Lew et al., 2009; Wolters et al., 2004; Nuno et al.,
1997; Wolters et al., 2002).
With the chosen solver technique and parameterizations and the current
implementation in SimBio-NeuroFEM, computing one row of a transfer matrix (Wolters et al., 2004) in a model with
about 17 Mio. nodes took about half an hour, resulting in an overall computation
time for the full 329 electrodes transfer matrix of about five days. However,
this computation step only needs to be performed once per model and
sensor-configuration. Afterwards, forward simulation can be performed in just
about a hundred of milliseconds per dipole. For our high source space resolution
with more than 2 Mio. nodes, the computation of the leadfield for all dipoles
still took 3 days. Without calculating a transfer matrix beforehand, one forward
simulation for a model with about 17 Mio. unknowns would have lasted
approximately half an hour, which would have resulted in an excessive
computational amount of more than 70 years. The transfer matrix technique (Wolters et al., 2004) was hence crucial
for the computational feasibility of our study.In the future, computation times may still significantly be reduced: for
example, a lower IC(0)-CG solver accuracy might be sufficient for nearly all
applications (Lew et al., 2009) which
would be interesting to evaluate. The setup of the transfer matrix could be sped
up by more than ten-fold when using the faster Algebraic MultiGrid
preconditioned Conjugate Gradient (AMG-CG) FEM solver (Lew et al., 2009; Wolters et al., 2002; Stüben, 2001), at the cost of higher memory usage in the
current implementation in SimBio-NeuroFEM. Parallelization on distributed memory
machines (Wolters et al., 2002; Krechel and Stüben, 2001) could
still significantly reduce both computation time and memory load. Most
importantly, in routine source analysis scenarios, usually no more than 30,000
source space nodes are used, which would reduce the forward modeling computation
time from 3 days down to about an hour. With such optimization, together with
increased hardware performance, we anticipate that sub-mm FEM head modeling may
become amendable for routine applications in science and neurological
diagnostics.
Limitations and further perspectives
Several limitations have to be considered when interpreting the
presented results. First, our results are based on only one subject, and blood
vessels show inter-individual variability (Benninghoff, 1993; Boyd,
1930; van der Zwan and Hillen,
1991; Tatu et al., 2012). Yet,
the general layout of the cerebral vasculature is quite similar across
individuals, both with respect to the major vessels and the location of brain
regions with a dense vasculature, such as the insular region (Benninghoff, 1993; Netter, 1987). Hence, as the strongest errors were located in these
regions, we expect that vessel-related errors will be present at similar levels
and locations in other subjects as well.Second, the accuracy of the presented model could still be improved. As
mentioned before, few superficial cortical and dura vessels and no draining
sinuses (Nowinski et al., 2011) were
included in the model because of their lower CNR. Incorporating these vessels is
expected to even further increase the proportion of the potentially-affected
brain regions, particularly in the cortex, which would be highly relevant for
source reconstruction. We expect that, due to blood-volume conservation,
including missing veins into our model would substantially increase the volume
occupied by blood vessels. Such extended models could use susceptibility
weighted imaging data at 7 T, for segmenting veins. Also co-registration of a 7
T blood vessel atlas (Nowinski et al.,
2011) with our model could possibly enable us to better evaluate the
true extent of blood vessels to be included in an enhanced model. Likewise, not
all blood vessel foramina and intraosseous veins could be segmented in our
current model, resulting in a likely underestimation of the resulting modeling
errors. We segmented 4 out of 9 and 3 out of 4 previously described foramina
containing blood vessels (Boyd, 1930;
Benninghoff, 1994) and intraosseous
veins (Benninghoff, 1993; Netter, 1987), respectively. The foramina
mastoide, condyloide, vesalius,
caecum and squamosale as well as the venae
diploicae temporalis anterior could not be segmented. This might be
due to the interindividual variability of diploe veins (Benninghoff, 1993) and foramina size and location
(Boyd, 1930).Moreover, there are several areas where the current segmentation could
still be improved. For example, hyperintensities in the temporal lobe and local
susceptibility artifacts above the lamina cribosa of the ethmoid sinuses created
small segmentation errors. The spongy bone, here modeled as intraosseous and
emissary veins, could be further improved. The choroid plexus was modeled with
gray matter conductivity for lack of tissue specific values, but due to the deep
location of the plexus we expect small model errors. Other areas with possible
segmentation improvements are due to the lower CNR in the ventral part of the
imaging volumes (below cortex levels) and affected facial bones, buccal air,
muscle and the spinal cord (the last two were completely left out of the model).
Manual segmentation by neuroradiologists (current gold standard) could probably
have recovered most of the missing tissues, but is impractical for whole head
segmentation with a submillimeter resolution. Advances in high-field imaging, MR
sequence development and creating automated segmentation software optimized for
7 T MRI data should level these limitations in the near future.Finally, the use of homogeneous, standard conductivity values also
represents a limitation, since the values can be expected to be inhomogeneous in
the living brain and will vary from standard values acquired ex-vivo. Including
anisotropic conductivities in the model would be a first step to address this
issue. The increase in computational load induced by anisotropic conductivities
might be a limiting factor for 7 T-based head modeling. Because only a minority
of the blood vessels included in our model was within the white matter
compartment, we expect no major insights for the questions addressed in the
present study from modeling white matter anisotropy. Recent advances in
electrical impedance tomography (EIT) and more specifically in magnetic
resonance EIT (Zhang et al., 2008; Woo and Seo, 2008; Meng et al., 2013; Degirmenci and Eyuboglu, 2013; Kim
et al., 2008) suggest that using individualized anisotropic and
inhomogeneous conductivities for head modeling may be possible in the future,
opening up exciting new possibilities in volume conductor head modeling.
Conclusions & outlook
For applications directed at regions with little vasculature we would
suggest that, if the skull is modeled correctly and CSF, dura and anisotropy are
present in a VCHM, the modeling of blood vessels is a possible next step towards an
even lower model error that may or may not be necessary, depending on the accuracy
requirements of a study. For applications where high forward and/or inverse solution
accuracies are necessary and which address areas close to the interhemispheric
fissure, the temporal pole and the insula, the inclusion of blood vessels may be
highly relevant and as important as considering the CSF, dura, and white matter
anisotropy.Finding the most suitable modeling techniques for blood vessels requires
further attention. Depending on which conductivities are assumed for vessels, we
found different mechanism of error generation. As researchers (Butt et al., 1990; Crone
and Olesen, 1982) have measured the electrical
resistance of the brain endothelium (although in rat and frog),
two paths towards a solution are currently investigated: (i) implementing separate
compartments for blood vessel endothelium and lumen, requiring a volume mesh with
local resolution approaching the single μm, making the development of new
FEM technologies necessary; (ii) modeling the resistive properties of the
endothelium as electrical boundary conditions. Developing algorithms required for
both approaches and making resistances compatible with software is the subject of
our ongoing research. Once established, these methods will permit to investigate the
effect of the blood-CSF (choroid plexus) and arachnoid barriers, which are also a
combination of highly isolating tight junctions and conductive fluids. Further
investigations will also be needed to clarify the role of the apparent dependence of
blood conductivity and anisotropy relative to flow velocity and vessel diameter
observed in impedance — plethysmography and cardiology (Wtorek and Polinski, 2005; Sakamoto and Kanai, 1979). In this context, direct
measurements in animal models would also be highly useful to resolve the current
lack of data on the exact conductivity of cerebral vessels, which led us to model a
wide range of conductivity values in the present study.Beyond EEG, we can envision multiple applications which could benefit from
modeling blood vessels, also at submillimeter resolution. For example, submillimeter
head modeling could be especially well suited for modeling of transcranial
magnetic/direct current/alternating current stimulation to optimize the current flow
in targeted brain areas (Wagner et al.,
2014). Other applications like traumatology and fNIRS could profit even more
from the precise modeling of blood vessels. Furthermore, fMRI acquired at 7 T could
make use of the high blood vessel contrast in anatomical data to mask BOLD effects
arising from superficial cortical vessels which are often misinterpreted as cortical
activity.
Authors: Bryony C Heasman; Antonio Valentín; Gonzalo Alarcón; Jorge J García Seoane; Colin D Binnie; Chris N Guy Journal: J Clin Neurophysiol Date: 2002-04 Impact factor: 2.177
Authors: Stefan Maderwald; Susanne C Ladd; Elke R Gizewski; Oliver Kraff; Jens M Theysohn; Karsten Wicklow; Christoph Moenninghoff; Isabel Wanke; Mark E Ladd; Harald H Quick Journal: MAGMA Date: 2008-01-04 Impact factor: 2.310
Authors: T D Waberski; R Gobbelé; G Herrendorf; B J Steinhoff; R Kolle; M Fuchs; W Paulus; H Buchner Journal: Epilepsia Date: 2000-12 Impact factor: 5.864
Authors: Seyhmus Guler; Moritz Dannhauer; Burak Erem; Rob Macleod; Don Tucker; Sergei Turovets; Phan Luu; Deniz Erdogmus; Dana H Brooks Journal: J Neural Eng Date: 2016-05-06 Impact factor: 5.379
Authors: Steven Beumer; Paul Boon; Debby C W Klooster; Raymond van Ee; Evelien Carrette; Maarten M Paulides; Rob M C Mestrom Journal: Brain Sci Date: 2022-05-07
Authors: Lukas Dominique Josef Fiederer; Jacob Lahr; Johannes Vorwerk; Felix Lucka; Ad Aertsen; Carsten Hermann Wolters; Andreas Schulze-Bonhage; Tonio Ball Journal: IEEE Trans Biomed Eng Date: 2016-07-19 Impact factor: 4.538
Authors: Ü Aydin; S Rampp; A Wollbrink; H Kugel; J -H Cho; T R Knösche; C Grova; J Wellmer; C H Wolters Journal: Brain Topogr Date: 2017-05-16 Impact factor: 3.020
Authors: Maria Carla Piastra; Andreas Nüßing; Johannes Vorwerk; Maureen Clerc; Christian Engwer; Carsten H Wolters Journal: Hum Brain Mapp Date: 2020-11-06 Impact factor: 5.399