Literature DB >> 26744180

Quantitative in vivo biocompatibility of new ultralow-nickel cobalt-chromium-molybdenum alloys.

Kazuaki Sonofuchi1, Yoshihiro Hagiwara1, Yuichiro Koizumi2, Akihiko Chiba2, Mitsuko Kawano3, Masafumi Nakayama3, Kouetsu Ogasawara3, Yutaka Yabe1, Eiji Itoi1.   

Abstract

Nickel (Ni) eluted from metallic biomaterials is widely accepted as a major cause of allergies and inflammation. To improve the safety of cobalt-chromium-molybdenum (Co-Cr-Mo) alloy implants, new ultralow-Ni Co-Cr-Mo alloys with and without zirconium (Zr) have been developed, with Ni contents of less than 0.01%. In the present study, we investigated the biocompatibility of these new alloys in vivo by subcutaneously implanting pure Ni, conventional Co-Cr-Mo, ultralow-Ni Co-Cr-Mo, and ultralow-Ni Co-Cr-Mo with Zr wires into the dorsal sides of mice. After 3 and 7 days, tissues around the wire were excised, and inflammation; the expression of IL-1β, IL-6, and TNF-α; and Ni, Co, Cr, and Mo ion release were analyzed using histological analyses, qRT-PCR, and inductively coupled plasma mass spectrometry (ICP-MS), respectively. Significantly larger amounts of Ni eluted from pure Ni wires than from the other wires, and the degree of inflammation depended on the amount of eluted Ni. Although no significant differences in inflammatory reactions were identified among new alloys and conventional Co-Cr-Mo alloys in histological and qRT-PCR analyses, ICP-MS analysis revealed that Ni ion elution from ultralow-Ni Co-Cr-Mo alloys with and without Zr was significantly lower than from conventional Co-Cr-Mo alloys. Our study, suggests that the present ultralow-Ni Co-Cr-Mo alloys with and without Zr have greater safety and utility than conventional Co-Cr-Mo alloys.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1505-1513, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  cobalt-chromium-molybdenum alloy; metal ions; nickel

Mesh:

Substances:

Year:  2016        PMID: 26744180     DOI: 10.1002/jor.23150

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Zirconium Nitride Coating Reduced Staphylococcus epidermidis Biofilm Formation on Orthopaedic Implant Surfaces: An In Vitro Study.

Authors:  Magdalena Pilz; Kevin Staats; Selma Tobudic; Ojan Assadian; Elisabeth Presterl; Reinhard Windhager; Johannes Holinka
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

2.  Evaluation of Topographical Co-Cr-Mo Alloy Surface Changes After Various Finishing Treatments.

Authors:  Ştefan Ţălu; Sebastian Stach; Boris Klaić; Asja Čelebić
Journal:  Acta Stomatol Croat       Date:  2019-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.