Literature DB >> 26737443

A chair for cuffless real-time estimation of systolic blood pressure based on pulse transit time.

Zunyi Tang, Masaki Sekine, Toshiyo Tamura, Masaki Yoshida, Wenxi Chen.   

Abstract

This study presents an unobtrusive cuffless blood pressure (BP) monitoring system for estimating beat-by-beat systolic blood pressure (SBP) in real-time based on pulse transit time (PTT). The system mainly includes an electrocardiograph with three conductive textile electrodes, a pulse monitor with a LED and a photodetector, a control circuit with a Bluetooth module, and a battery, all of which are mounted on a common armchair to measure ECG and photoplethysmography (PPG) signals from users during sitting on the armchair. The measured ECG and PPG data are transmitted to the software terminal installed on a tablet PC and are further derived to obtain a series of PTT for estimating beat-by-beat BP using Chen's method. We had 9 healthy subjects undergo the BP monitoring experiments of still sitting on a chair for 3 minutes, lying on a bed for 10 minutes, and pedaling using ergometer for 11 minutes in order to assess the accuracy of the estimated BP. A Finometer and a cuff-type BP meter were used as references in the experiments. Preliminary results showed that the mean error and mean absolute difference (MAD) of estimated BP were within -0.5 ± 5.3 mmHg and 4.1 ± 3.4 mmHg, respectively, compared to references. The result suggests that the proposed BP estimation system has the potential for long-term home BP monitoring.

Entities:  

Mesh:

Year:  2015        PMID: 26737443     DOI: 10.1109/EMBC.2015.7319543

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Cuffless Blood Pressure Measurement Using a Smartphone-Case Based ECG Monitor with Photoplethysmography in Hypertensive Patients.

Authors:  Zhanna Sagirova; Natalia Kuznetsova; Nana Gogiberidze; Daria Gognieva; Aleksandr Suvorov; Petr Chomakhidze; Stefano Omboni; Hugo Saner; Philippe Kopylov
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

Review 2.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

3.  A Research Roadmap: Connected Health as an Enabler of Cancer Patient Support.

Authors:  Gabriel Ruiz Signorelli; Fedor Lehocki; Matilde Mora Fernández; Gillian O'Neill; Dominic O'Connor; Louise Brennan; Francisco Monteiro-Guerra; Alejandro Rivero-Rodriguez; Santiago Hors-Fraile; Juan Munoz-Penas; Mercè Bonjorn Dalmau; Jorge Mota; Ricardo B Oliveira; Bela Mrinakova; Silvia Putekova; Naiara Muro; Francisco Zambrana; Juan M Garcia-Gomez
Journal:  J Med Internet Res       Date:  2019-10-29       Impact factor: 5.428

4.  Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training.

Authors:  Treesukon Treebupachatsakul; Apivitch Boosamalee; Siratchakrit Shinnakerdchoke; Suejit Pechprasarn; Nuntachai Thongpance
Journal:  Biosensors (Basel)       Date:  2022-03-04
  4 in total