Literature DB >> 26733512

Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.

S A Hanna1, L Somerville1, R W McCalden1, D D Naudie1, S J MacDonald1.   

Abstract

AIMS: The purpose of this study was to compare the long-term results of primary total hip arthroplasty (THA) in young patients using either a conventional (CPE) or a highly cross-linked (HXLPE) polyethylene liner in terms of functional outcome, incidence of osteolysis, radiological wear and rate of revision.
METHODS: We included all patients between the ages of 45 and 65 years who, between January 2000 and December 2001, had undergone a primary THA for osteoarthritis at our hospital using a CPE or HXLPE acetabular liner and a 28 mm cobalt-chrome femoral head. From a total of 160 patients, 158 (177 hips) were available for review (CPE 89; XLPE 88). The mean age, body mass index (BMI) and follow-up in each group were: CPE: 56.8 years (46 to 65); 30.7 kg/m(2) (19 to 58); 13.2 years (2.1 to 14.7) and HXLPE: 55.6 years (45 to 65); BMI: 30 kg/m(2) (18 to 51); 13.1 years (5.7 to 14.4).
RESULTS: The mean Harris hip score (HHS) at final follow-up was 89.3 for the CPE group and 90.9 for the HXLPE group (p = 0.078). Osteolysis was present around 15 acetabular (17%) and 16 femoral (18%) components in the CPE hips compared with none (0%) in the HXLPE hips. The mean radiological linear wear of the CPE liners was 0.11 mm/year compared with 0.035 mm/year for the HXLPE liners (p = 0.006). The cumulative implant survival, with revision for polyethylene wear as the endpoint, was 86% (95% confidence interval 78 to 94) in the CPE group and 100% in the HXLPE group at 13 years (numbers at risk at 13 years - CPE: 65, XLPE: 61). DISCUSSION: This study shows that HXLPE liners are associated with significantly less osteolysis and a lower rate of revision THA than CPE liners at long-term follow-up. TAKE HOME MESSAGE: The findings of this study highlight the clinical benefits of using HXLPE liners in THA and support the routine use of the material in order to improve implant longevity and to decrease the number of patients needing revision for aseptic osteolysis. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Conventional; Cross-Linked; Polyethylene; Revision; Total Hip Arthroplasty (THA); Wear

Mesh:

Substances:

Year:  2016        PMID: 26733512     DOI: 10.1302/0301-620X.98B1.36527

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  28 in total

1.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

2.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

Review 3.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

4.  Total hip arthroplasty using direct anterior approach and dual mobility cup: safe and efficient strategy against post-operative dislocation.

Authors:  Cécile Batailler; Camdon Fary; Pierre Batailler; Elvire Servien; Philippe Neyret; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-16       Impact factor: 3.075

5.  CORR Insights®: Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.

Authors:  Richard W McCalden
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

6.  CORR Insights®: Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study.

Authors:  Jonathan P Garino
Journal:  Clin Orthop Relat Res       Date:  2019-12       Impact factor: 4.176

7.  Patients 10 years after total hip arthroplasty have the deficits in functional performance, physical activity, and high fall rate compared to healthy adults.

Authors:  Kazunari Ninomiya; Kazuo Hirakawa; Takashi Ikeda; Nariaki Nakura; Koji Suzuki
Journal:  Phys Ther Res       Date:  2018-10-20

8.  Delay of total hip arthroplasty to advanced stage worsens post-operative hip motion in patients with femoral head osteonecrosis.

Authors:  Woo-Lam Jo; Young-Kyun Lee; Yong-Chan Ha; Tae-Young Kim; Kyung-Hoi Koo
Journal:  Int Orthop       Date:  2018-04-26       Impact factor: 3.075

9.  Less Midterm Damage and Oxidation Are Seen in Retrieved Highly Crosslinked Ultrahigh-Molecular-Weight Polyethylene Tibial Inserts than in Direct Compression Molded Polyethylene Inserts.

Authors:  Alexandra Stavrakis; Lydia Weitzler; Timothy Wright; Douglas E Padgett
Journal:  HSS J       Date:  2018-03-26

10.  Thirteen-year wear rate comparison of highly crosslinked and conventional polyethylene in total hip arthroplasty: long-term follow-up of a prospective randomized controlled trial.

Authors:  Matthew G Teeter; Xunhua Yuan; Lyndsay E Somerville; Steven J MacDonald; Richard W McCalden; Douglas D Naudie
Journal:  Can J Surg       Date:  2017-06       Impact factor: 2.089

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.