Literature DB >> 26733509

Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition Part 1 - history, mechanism, measurements, and pathophysiology.

A C Cheung1, S Banerjee2, J J Cherian2, F Wong1, J Butany1, C Gilbert1, C Overgaard1, K Syed3, M G Zywiel3, J J Jacobs4, M A Mont2.   

Abstract

UNLABELLED: Recently, the use of metal-on-metal articulations in total hip arthroplasty (THA) has led to an increase in adverse events owing to local soft-tissue reactions from metal ions and wear debris. While the majority of these implants perform well, it has been increasingly recognised that a small proportion of patients may develop complications secondary to systemic cobalt toxicity when these implants fail. However, distinguishing true toxicity from benign elevations in cobalt ion levels can be challenging. The purpose of this two part series is to review the use of cobalt alloys in THA and to highlight the following related topics of interest: mechanisms of cobalt ion release and their measurement, definitions of pathological cobalt ion levels, and the pathophysiology, risk factors and treatment of cobalt toxicity. Historically, these metal-on-metal arthroplasties are composed of a chromium-cobalt articulation. The release of cobalt is due to the mechanical and oxidative stresses placed on the prosthetic joint. It exerts its pathological effects through direct cellular toxicity. This manuscript will highlight the pathophysiology of cobalt toxicity in patients with metal-on-metal hip arthroplasties. TAKE HOME MESSAGE: Patients with new or evolving hip symptoms with a prior history of THA warrant orthopaedic surgical evaluation. Increased awareness of the range of systemic symptoms associated with cobalt toxicity, coupled with prompt orthopaedic intervention, may forestall the development of further complications. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Hip; Metal-on-metal; cobalt; tociity

Mesh:

Substances:

Year:  2016        PMID: 26733509     DOI: 10.1302/0301-620X.98B1.36374

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  26 in total

1.  Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs; Robert M Urban
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-11-30       Impact factor: 3.368

2.  Letter to the Editor: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases.

Authors:  Gulraj S Matharu; Michael R Whitehouse
Journal:  Clin Orthop Relat Res       Date:  2018-12       Impact factor: 4.176

3.  CORR Insights®: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases.

Authors:  Hilal Maradit Kremers
Journal:  Clin Orthop Relat Res       Date:  2018-07       Impact factor: 4.176

4.  The gut microbiota may be a novel pathogenic mechanism in loosening of orthopedic implants in rats.

Authors:  Meghan M Moran; Brittany M Wilson; Jun Li; Phillip A Engen; Ankur Naqib; Stefan J Green; Amarjit S Virdi; Anna Plaas; Christopher B Forsyth; Ali Keshavarzian; Dale R Sumner
Journal:  FASEB J       Date:  2020-09-15       Impact factor: 5.191

Review 5.  Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.

Authors:  Ming Han Lincoln Liow; Young-Min Kwon
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

6.  Drp-1-Dependent Mitochondrial Fragmentation Contributes to Cobalt Chloride-Induced Toxicity in Caenorhabditis elegans.

Authors:  Fuli Zheng; Pan Chen; Huangyuan Li; Michael Aschner
Journal:  Toxicol Sci       Date:  2020-09-01       Impact factor: 4.849

7.  Off-resonance based assessment of metallic wear debris near total hip arthroplasty.

Authors:  Kevin M Koch; Matthew F Koff; Thomas W Bauer; Parina H Shah; Andrew S Nencka; S Sivaram Kaushik; Hollis G Potter
Journal:  Magn Reson Med       Date:  2017-06-22       Impact factor: 4.668

8.  Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations.

Authors:  James H Ho; Jerrold B Leikin; Paul I Dargan; John R H Archer; David M Wood; Jeffrey Brent
Journal:  J Med Toxicol       Date:  2017-09-12

9.  Molecular pathology of adverse local tissue reaction caused by metal-on-metal implants defined by RNA-seq.

Authors:  Christopher G Salib; Eric A Lewallen; Christopher R Paradise; Meagan E Tibbo; Joseph X Robin; William H Trousdale; Logan M Morrey; Jason Xiao; Travis W Turner; Afton K Limberg; Anthony G Jay; Roman Thaler; Amel Dudakovic; Joaquin Sanchez-Sotelo; Mark E Morrey; Daniel J Berry; David G Lewallen; Andre J van Wijnen; Matthew P Abdel
Journal:  Genomics       Date:  2018-09-21       Impact factor: 5.736

10.  Chromium and Nickel Concentrations in Subjects with a Stainless Steel Metal-on-Metal Cervical Disc Arthroplasty: Results from a Prospective Longitudinal Study with 7 Years Follow-Up.

Authors:  Vaneet Singh; Anastasia K Skipor; Abdulhafez A Selim; Joshua J Jacobs
Journal:  Int J Spine Surg       Date:  2018-08-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.