Literature DB >> 26726098

Cementless Corail™ femoral stems with laser neck etching: Long-term survival, rupture rate and risk factors in 295 stems.

A Merini1, A Viste2, R Desmarchelier1, M-H Fessy3.   

Abstract

INTRODUCTION: Implant neck fracture involving a non-modular femoral stem is rare in primary total hip arthroplasty (THA). Occasional cases have been reported following laser etching of the Corail(tm) stem, but risk factors have not been precisely determined. We therefore performed a retrospective study on a series of Corail(tm) stems with laser neck etching, in order to: (1) determine the exact implant neck fracture rate at 10 years, and (2) identify associated risk factors. HYPOTHESIS: Laser etching increases the rate of implant neck fracture.
MATERIALS AND METHODS: Between October 2002 and December 2003, 295 THAs were consecutively performed using the Corail(tm) stem with laser neck etching, in 286 patients: 151 male (53%), 135 female (47%); mean age, 63 years (range, 18-89 years); mean weight, 73kg (range, 45-120kg). Stems were standard in 240 cases (81%) and lateralized in 55 (19%). The main assessment criterion was stem replacement for implant neck fracture.
RESULTS: At a mean 10 years' follow-up (range, 1-11 years), 11 patients were lost to follow-up (4%) and 35 had died (12%) (with stem in situ). Overall 10-year stem survival was 91% (95% CI: [87-94%]). Sixteen patients (5.4%) underwent revision surgery for implant neck fracture, 6 (2%) bone and joint infection and in 4 cases (1.3%) the stem was replaced preventively for fracture risk suspected during a revision procedure on the cup. All fractures were of the fatigue type, implicating implant neck laser etching. Mean time to fracture was 4.5 years (range, 1.4-9.8 years). Risk factors comprised: weight>80kg (P=0.002) (OR=5.7; 95% CI: 1.9-17), age<60 years (P=0.02) (OR=3.4; 95% CI: 1.2-9.6), male gender (P=0.01) (OR=14.8; 95% CI: 1.9-113) and lateralized stem (P<0.001) (OR=6.5, 95% CI: 2.3-18).
CONCLUSION: The present 5.4% fracture rate was higher than in registry data (<1%). Fracture mechanisms involved excessive stress in an area under tension, leading to fatigue fracture. Male gender, high weight and young age were risk factors, as in the literature for fatigue fracture. Location and depth of laser etching induced fatigue fracture. The study demonstrated that laser etching creates an area of weakness in the implant neck and should therefore be eschewed in this part of the femoral stem. LEVEL OF EVIDENCE: IV, retrospective study.
Copyright © 2015 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Corail(tm) stem; Laser etching; Stem neck fracture; Total hip arthroplasty

Mesh:

Year:  2015        PMID: 26726098     DOI: 10.1016/j.otsr.2015.10.009

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  4 in total

1.  The Actis and Corail Femoral Stems Provide for Similar Clinical and Radiographic Outcomes in Total Hip Arthroplasty.

Authors:  Stephanie V Kaszuba; Nancy Cipparrone; Alexander C Gordon
Journal:  HSS J       Date:  2020-09-10

Review 2.  Long-term survival of CLS Spotorno femoral stem: a systematic review of literature.

Authors:  Mandeep Singh Dhillon; Karan Jindal; Prasoon Kumar; Rajesh Kumar Rajnish; Deepak Neradi
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-06       Impact factor: 3.067

3.  Fracture of the Neck of a Modern Cementless, Titanium Femoral Stem.

Authors:  Emmanuel Gibon; Justin T Deen
Journal:  Arthroplast Today       Date:  2020-05-11

4.  Femoral Stem Fracture in Hip Revision Arthroplasty: A Systematic Literature Review of the Real-World Evidence.

Authors:  Matthias Sukopp; Dominic Taylor; Raimund Forst; Frank Seehaus
Journal:  Z Orthop Unfall       Date:  2021-04-13       Impact factor: 0.923