Literature DB >> 26723340

Simulating environmental and psychological acoustic factors of the operating room.

Christopher L Bennett1, Roman Dudaryk2, Andrew L Ayers3, Richard R McNeer4.   

Abstract

In this study, an operating room simulation environment was adapted to include quadraphonic speakers, which were used to recreate a composed clinical soundscape. To assess validity of the composed soundscape, several acoustic parameters of this simulated environment were acquired in the presence of alarms only, background noise only, or both. These parameters were also measured for comparison from size-matched operating rooms at Jackson Memorial Hospital. The parameters examined included sound level, reverberation time, and predictive metrics of speech intelligibility in quiet and noise. It was found that the sound levels and acoustic parameters were comparable between the simulated environment and the actual operating rooms. The impact of the background noise on the perception of medical alarms was then examined, and was found to have little impact on the audibility of the alarms. This study is a first in kind report of a comparison between the environmental and psychological acoustical parameters of a hospital simulation environment and actual operating rooms.

Mesh:

Year:  2015        PMID: 26723340     DOI: 10.1121/1.4936947

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  4 in total

1.  Acoustic features of auditory medical alarms-An experimental study of alarm volume.

Authors:  Joseph J Schlesinger; Sarah H Baum Miller; Katherine Nash; Marissa Bruce; Daniel Ashmead; Matthew S Shotwell; Judy R Edworthy; Mark T Wallace; Matthew B Weinger
Journal:  J Acoust Soc Am       Date:  2018-06       Impact factor: 1.840

2.  Factors Affecting Acoustics and Speech Intelligibility in the Operating Room: Size Matters.

Authors:  Richard R McNeer; Christopher L Bennett; Danielle Bodzin Horn; Roman Dudaryk
Journal:  Anesth Analg       Date:  2017-06       Impact factor: 5.108

3.  Modifications of Surgical Suction Tip Geometry for Flow Optimisation: Influence on Suction-Induced Noise Pollution.

Authors:  M G Friedrich; T Tirilomis; J M Kollmeier; Y Wang; G G Hanekop
Journal:  Surg Res Pract       Date:  2018-11-21

4.  Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator.

Authors:  Richard R McNeer; Roman Dudaryk; Nicholas B Nedeff; Christopher L Bennett
Journal:  Anesthesiol Res Pract       Date:  2016-05-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.