Literature DB >> 26718786

Immediate postarousal sleep dynamics: an important determinant of sleep stability in obstructive sleep apnea.

Magdy Younes1, Patrick J Hanly2.   

Abstract

Arousability from sleep is increasingly recognized as an important determinant of the clinical spectrum of sleep disordered breathing (SDB). Patients with SDB display a wide range of arousability. The reason for these differences is not known. We hypothesized that differences in the speed with which sleep deepens following arousals/awakenings (postarousal sleep dynamics) is a major determinant of these differences in arousability in patients with SDB. We analyzed 40 preexisting clinical polysomnography records from patients with a range of SDB severity (apnea-hypopnea index 5-135/h). Sleep depth was determined every 3 s using the odds ratio product (ORP) method, a continuous index of sleep depth (0 = deep sleep, 2.5 = full wakefulness) that correlates strongly (r = 0.98) with arousability (Younes M, Ostrowski M, Soiferman M, Younes H, Younes M, Raneri J, and Hanly P. Sleep 38: 641-654, 2015). Time course of ORP was determined from end of arousal until the next arousal. All arousals were analyzed (142 ± 65/polysomnogram). ORP increased from 0.58 ± 0.32 during sleep to 1.67 ± 0.35 during arousals. ORP immediately (first 9 s) following arousals/awakenings (ORP-9) ranged from 0.21(very deep sleep) to 1.71 (highly arousable state) in different patients. In patients with high ORP-9, sleep deepened slowly (over minutes) beyond 9 s but only if no arousals/awakenings recurred. ORP-9 correlated strongly with average non-rapid eye movement sleep depth (r = 0.87, P < 2E-13), the arousal/awakening index (r = 0.68, P < 5E-6), and with the apnea-hypopnea index (r = 0.60, P < 0.001). ORP-9 was consistent within each patient and did not change on continuous positive airway pressure despite marked improvement in sleep architecture. We conclude that postarousal sleep dynamics are highly variable among patients with sleep-disordered breathing and largely determine average sleep depth and continuity.
Copyright © 2016 the American Physiological Society.

Entities:  

Keywords:  arousal index; obstructive sleep apnea sleep quality; odds ratio product

Mesh:

Year:  2015        PMID: 26718786     DOI: 10.1152/japplphysiol.00880.2015

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  18 in total

1.  Performance of a New Portable Wireless Sleep Monitor.

Authors:  Magdy Younes; Marc Soiferman; Wayne Thompson; Eleni Giannouli
Journal:  J Clin Sleep Med       Date:  2017-02-15       Impact factor: 4.062

Review 2.  Opportunities for utilizing polysomnography signals to characterize obstructive sleep apnea subtypes and severity.

Authors:  Diego R Mazzotti; Diane C Lim; Kate Sutherland; Lia Bittencourt; Jesse W Mindel; Ulysses Magalang; Allan I Pack; Philip de Chazal; Thomas Penzel
Journal:  Physiol Meas       Date:  2018-09-13       Impact factor: 2.833

3.  The Odds Ratio Product (An Objective Sleep Depth Measure): Normal Values, Repeatability, and Change With CPAP in Patients With OSA.

Authors:  Charles Gerhard Penner; Bethany Gerardy; Rob Ryan; Mark Williams
Journal:  J Clin Sleep Med       Date:  2019-08-15       Impact factor: 4.062

4.  Reliability of the American Academy of Sleep Medicine Rules for Assessing Sleep Depth in Clinical Practice.

Authors:  Magdy Younes; Samuel T Kuna; Allan I Pack; James K Walsh; Clete A Kushida; Bethany Staley; Grace W Pien
Journal:  J Clin Sleep Med       Date:  2018-02-15       Impact factor: 4.062

5.  Impaired central control of sleep depth propensity as a common mechanism for excessive overnight wake time: implications for sleep apnea, insomnia and beyond.

Authors:  Danny J Eckert; Alexander Sweetman
Journal:  J Clin Sleep Med       Date:  2020-01-14       Impact factor: 4.062

6.  Mechanism of excessive wake time when associated with obstructive sleep apnea or periodic limb movements.

Authors:  Magdy Younes; Eleni Giannouli
Journal:  J Clin Sleep Med       Date:  2020-01-14       Impact factor: 4.062

7.  Arousal Intensity is a Distinct Pathophysiological Trait in Obstructive Sleep Apnea.

Authors:  Jason Amatoury; Ali Azarbarzin; Magdy Younes; Amy S Jordan; Andrew Wellman; Danny J Eckert
Journal:  Sleep       Date:  2016-12-01       Impact factor: 5.849

Review 8.  Reinventing polysomnography in the age of precision medicine.

Authors:  Diane C Lim; Diego R Mazzotti; Kate Sutherland; Jesse W Mindel; Jinyoung Kim; Peter A Cistulli; Ulysses J Magalang; Allan I Pack; Philip de Chazal; Thomas Penzel
Journal:  Sleep Med Rev       Date:  2020-03-20       Impact factor: 11.609

9.  Nocturnal swallowing augments arousal intensity and arousal tachycardia.

Authors:  P G R Burke; S G Carter; F Knapman; J Patti; M Butlin; S C Gandevia; J E Butler; D J Eckert; L E Bilston
Journal:  Proc Natl Acad Sci U S A       Date:  2020-03-30       Impact factor: 11.205

10.  Sleep Architecture in Night Shift Workers Police Officers with Obstructive Sleep Apnea-hypopnea Syndrome.

Authors:  Selene Verde-Tinoco; Rafael Santana-Miranda; Romel Gutiérrez-Escobar; Reyes Haro; Joana Miranda-Ortiz; Talia Berruga-Fernandez; Ulises Jimenez-Correa; Adrián Poblano
Journal:  Sleep Sci       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.