Handheld Fluorescence Microscopy based Flow Analyzer.

Manish Saxena1,2, Nitin Jayakumar3, Sai Siva Gorthi4.   

Abstract

Fluorescence microscopy has the intrinsic advantages of favourable contrast characteristics and high degree of specificity. Consequently, it has been a mainstay in modern biological inquiry and clinical diagnostics. Despite its reliable nature, fluorescence based clinical microscopy and diagnostics is a manual, labour intensive and time consuming procedure. The article outlines a cost-effective, high throughput alternative to conventional fluorescence imaging techniques. With system level integration of custom-designed microfluidics and optics, we demonstrate fluorescence microscopy based imaging flow analyzer. Using this system we have imaged more than 2900 FITC labeled fluorescent beads per minute. This demonstrates high-throughput characteristics of our flow analyzer in comparison to conventional fluorescence microscopy. The issue of motion blur at high flow rates limits the achievable throughput in image based flow analyzers. Here we address the issue by computationally deblurring the images and show that this restores the morphological features otherwise affected by motion blur. By further optimizing concentration of the sample solution and flow speeds, along with imaging multiple channels simultaneously, the system is capable of providing throughput of about 480 beads per second.

Entities:  

Keywords:  Fluorescence imaging; Microfluidics; Microscopy; Opto-fluidics

Year:  2015        PMID: 26715517     DOI: 10.1007/s10895-015-1749-0

Source DB:  PubMed          Journal:  J Fluoresc        ISSN: 1053-0509            Impact factor:   2.217


  13 in total

1.  Microfabricated multiple field of view imaging flow cytometry.

Authors:  Ethan Schonbrun; Sai Siva Gorthi; Diane Schaak
Journal:  Lab Chip       Date:  2011-10-31       Impact factor: 6.799

Review 2.  Fluorescence microscopy.

Authors:  Jeff W Lichtman; José-Angel Conchello
Journal:  Nat Methods       Date:  2005-12       Impact factor: 28.547

Review 3.  Fluorescence microscopy today.

Authors:  Rafael Yuste
Journal:  Nat Methods       Date:  2005-12       Impact factor: 28.547

4.  An integrated fluorescence detection system for lab-on-a-chip applications.

Authors:  Lukas Novak; Pavel Neuzil; Juergen Pipper; Yi Zhang; Shinhan Lee
Journal:  Lab Chip       Date:  2006-11-21       Impact factor: 6.799

5.  Cellular image analysis and imaging by flow cytometry.

Authors:  David A Basiji; William E Ortyn; Luchuan Liang; Vidya Venkatachalam; Philip Morrissey
Journal:  Clin Lab Med       Date:  2007-09       Impact factor: 1.935

6.  A light sheet based high throughput 3D-imaging flow cytometer for phytoplankton analysis.

Authors:  Jianglai Wu; Jianping Li; Robert K Y Chan
Journal:  Opt Express       Date:  2013-06-17       Impact factor: 3.894

7.  Sheathless inertial cell ordering for extreme throughput flow cytometry.

Authors:  Soojung Claire Hur; Henry Tat Kwong Tse; Dino Di Carlo
Journal:  Lab Chip       Date:  2009-12-18       Impact factor: 6.799

8.  Fluorescence imaging of flowing cells using a temporally coded excitation.

Authors:  Sai Siva Gorthi; Diane Schaak; Ethan Schonbrun
Journal:  Opt Express       Date:  2013-02-25       Impact factor: 3.894

9.  Optofluidic fluorescent imaging cytometry on a cell phone.

Authors:  Hongying Zhu; Sam Mavandadi; Ahmet F Coskun; Oguzhan Yaglidere; Aydogan Ozcan
Journal:  Anal Chem       Date:  2011-08-02       Impact factor: 6.986

10.  Microfluidic CD4+ and CD8+ T lymphocyte counters for point-of-care HIV diagnostics using whole blood.

Authors:  Nicholas N Watkins; Umer Hassan; Gregory Damhorst; Hengkan Ni; Awais Vaid; William Rodriguez; Rashid Bashir
Journal:  Sci Transl Med       Date:  2013-12-04       Impact factor: 17.956

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.