Impact of Acquisition Method and Region of Interest Placement on Inter-observer Agreement and Measurement of Tumor Response to Targeted Therapy Using Dynamic Contrast-Enhanced Ultrasound.

Mostafa Atri1, John M Hudson2, Mehrdad Sinaei3, Ross Williams4, Laurent Milot5, Hadas Moshonov3, Peter N Burns2, Georg A Bjarnason6.   

Abstract

This study evaluated the impact of different acquisition methods, user-directed region of interest placement and post-processing steps on the quantification of dynamic contrast-enhanced ultrasound measurements of blood volume in 29 patients with renal cancer, pre- and post-treatment. Specifically, we compared tumor quantification using multiple planes versus a single plane, breathhold versus free breathing and large region of interest versus a region targeting the area of highest vascularity. Performance was evaluated using area under the receiver operating characteristic curves to identify the method that best predicts progression-free survival. The intra-class correlation coefficient was also used to investigate how the same parameters affect inter-observer agreement. Of the different methods used to quantify blood volume in this study, the combination that had the highest level of inter-observer agreement (intra-class correlation coefficient = 0.8-0.97) and was the best predictor of progression-free survival was the change in blood volume measured (area under receiver operating characteristic curve = 0.77, p = 0.04) by a multiplane average, acquired during quiet breathing, quantified using a region of interest that encompassed the entire tumor.
Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Inter-observer agreement; Treatment evaluation; Tumor blood flow; Ultrasound contrast

Mesh:

Substances:

Year:  2015        PMID: 26712416     DOI: 10.1016/j.ultrasmedbio.2015.11.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  Interobserver Variation of the Bolus-and-Burst Method for Pancreatic Perfusion with Dynamic - Contrast-Enhanced Ultrasound.

Authors:  Marcus Stangeland; Trond Engjom; Martin Mezl; Radovan Jirik; Odd Helge Gilja; Georg Dimcevski; Kim Nylund
Journal:  Ultrasound Int Open       Date:  2017-09-12

Review 2.  A Narrative Review of Ultrasound Technologies for the Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer.

Authors:  Jing Wang; Yanhua Chu; Baohua Wang; Tianan Jiang
Journal:  Cancer Manag Res       Date:  2021-10-14       Impact factor: 3.989

  2 in total