Literature DB >> 2671166

3-D visualization of arterial structures using ultrasound and Voxel modelling.

R I Kitney1, L Moura, K Straughan.   

Abstract

In this paper, a new type of vascular imaging system is presented which is designed for use in conjunction with percutaneous transluminal treatment techniques (balloon and laser angioplasty, atherectomy etc). Three dimensional computer models of arterial sections are reconstructed in full voxel space from data acquired using a purpose-built, catheter-mounted ultrasound probe. The system is standalone, using commercially available computer hardware and specially written software. The software is equally compatible with source data from other modalities (e.g. CT and MR), and the system can therefore be incorporated into a PACS environment.

Mesh:

Year:  1989        PMID: 2671166     DOI: 10.1007/bf01745143

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  1 in total

1.  Three-dimensional visualization of the intact thorax and contents: a technique for cross-sectional reconstruction from multiplanar x-ray views.

Authors:  R A Robb; J F Greenleaf; E L Ritman; S A Johnson; J D Sjostrand; G T Herman; E H Wood
Journal:  Comput Biomed Res       Date:  1974-08
  1 in total
  5 in total

1.  3D-surface reconstruction of intravascular ultrasound images using personal computer hardware and a motorized catheter control.

Authors:  H M Klein; R W Günther; M Verlande; W Schneider; D Vorwerk; J Kelch; M Hamm
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Mar-Apr       Impact factor: 2.740

2.  Intravascular ultrasound imaging for guidance of atherectomy and other plaque removal techniques.

Authors:  P G Yock; P J Fitzgerald; K Sudhir; D T Linker; W White; A Ports
Journal:  Int J Card Imaging       Date:  1991

3.  The effect of vascular curvature on three-dimensional reconstruction of intravascular ultrasound images.

Authors:  S P Wiet; M J Vonesh; M J Waligora; B J Kane; D D McPherson
Journal:  Ann Biomed Eng       Date:  1996 Nov-Dec       Impact factor: 3.934

4.  In vivo volumetric intravascular ultrasound visualization of early/inflammatory arterial atheroma using targeted echogenic immunoliposomes.

Authors:  Hyunggun Kim; Melanie R Moody; Susan T Laing; Patrick H Kee; Shao-Ling Huang; Melvin E Klegerman; David D McPherson
Journal:  Invest Radiol       Date:  2010-10       Impact factor: 6.016

5.  Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo.

Authors:  C von Birgelen; G S Mintz; E A de Vrey; T Kimura; J J Popma; S G Airiian; M B Leon; M Nobuyoshi; P W Serruys; P J de Feyter
Journal:  Heart       Date:  1998-02       Impact factor: 5.994

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.