Literature DB >> 2670419

Skin reactions to irritants assessed by non-invasive bioengineering methods.

T Agner1, J Serup.   

Abstract

Pathophysiological components of irritant contact dermatitis caused by 3 chemically-different irritants were investigated. 20 healthy volunteers were patch tested with sodium lauryl sulphate, nonanoic acid and hydrochloric acid on the flexor side of the upper arm. The skin response was evaluated after 24, 48 and 96 h by visual scoring and measured by the following bioengineering methods: transepidermal water loss measurement, electrical conductance for measurement of skin hydration, laser Doppler flowmetry for measurement of cutaneous blood flow and 20 MHz ultrasound A-scan for measurement of skin thickness. In spite of homogeneous inflammatory responses, significant differences in the severity of the injury to the skin barrier function caused by the different irritants were found. Also significant differences between irritants were found in the time course of development of maximum irritant reactions. Bioengineering methods indicating inflammatory responses (measurement of blood flow and skin thickness) were helpful in quantifying the irritant response in general, while bioengineering methods indicating epidermal damage (measurement of TEWL and electrical conductance) were helpful in classifying the individual irritants.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2670419     DOI: 10.1111/j.1600-0536.1989.tb03172.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  3 in total

1.  International guidelines for the in vivo assessment of skin properties in non-clinical settings: Part 2. transepidermal water loss and skin hydration.

Authors:  Johan du Plessis; Aleksandr Stefaniak; Fritz Eloff; Swen John; Tove Agner; Tzu-Chieh Chou; Rosemary Nixon; Markus Steiner; Anja Franken; Irena Kudla; Linn Holness
Journal:  Skin Res Technol       Date:  2013-01-19       Impact factor: 2.365

2.  Assessment of skin erythema by eye, laser Doppler flowmeter, spectroradiometer, two-channel erythema meter and Minolta chroma meter.

Authors:  A Lahti; H Kopola; A Harila; R Myllylä; M Hannuksela
Journal:  Arch Dermatol Res       Date:  1993       Impact factor: 3.017

3.  Long-term reliable physical health monitoring by sweat pore-inspired perforated electronic skins.

Authors:  Hanwool Yeon; Haneol Lee; Yeongin Kim; Doyoon Lee; Youngjoo Lee; Jong-Sung Lee; Jiho Shin; Chanyeol Choi; Ji-Hoon Kang; Jun Min Suh; Hyunseok Kim; Hyun S Kum; Jaeyong Lee; Daeyeon Kim; Kyul Ko; Boo Soo Ma; Peng Lin; Sangwook Han; Sungkyu Kim; Sang-Hoon Bae; Taek-Soo Kim; Min-Chul Park; Young-Chang Joo; Eunjoo Kim; Jiyeon Han; Jeehwan Kim
Journal:  Sci Adv       Date:  2021-06-30       Impact factor: 14.136

  3 in total