| Literature DB >> 26689926 |
M G Compier1, J Braun2, A Tjon3, K Zeppenfeld1, R J M Klautz2, M J Schalij1, S A Trines4.
Abstract
INTRODUCTION: Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block. METHODS ANDEntities:
Keywords: Atrial fibrillation; Box isolation; Posterior left atrium; Surgical ablation
Year: 2016 PMID: 26689926 PMCID: PMC4722013 DOI: 10.1007/s12471-015-0785-3
Source DB: PubMed Journal: Neth Heart J ISSN: 1568-5888 Impact factor: 2.380
Fig. 1Creation of the box including the left atrial posterior wall and pulmonary veins. (Medtronic Inc., Minneapolis)
Baseline characteristics
| Baseline characteristics | |
|---|---|
| Male % ( | 76 (19) |
| Age at operation (years, ± SD) | 58 ± 7 |
| Body mass index (kg/m2, ± SD) | 26 ± 3 |
| LA size (mm, ± SD) | 45 ± 5 |
| AF duration (years, ± SD) | 1.8 ± 0.9 |
| Previous ablations % ( | 12 (3) |
| Structural heart disease % ( | |
| - Mitral valve disease | 4 (1) |
| - Aortic valve disease | 8 (2) |
| - Cardiomyopathy | 4 (1) |
| Coronary artery disease % ( | 12 (3) |
| Hypertension % ( | 28 (7) |
| Diabetes mellitus % ( | 4 (1) |
| AADs before surgery ( | 2 ± 1 |
| CHA2DS2-VASc (score, ±SD) | 1.2 ± 1 |
AAD antiarrhythmic drug, AF atrial fibrillation, LA left atrium, SD standard deviation.
Procedural characteristics
| Procedural characteristics | |
|---|---|
| Ablation time (min, ± SD) | 9.3 ± 1.7 |
| Procedure time (min, ± SD) | 223 ± 54 |
| Entrance block box % ( | 100 (25) |
| Exit block box % ( | 80 (20) |
| Electrocardioversion % ( | 76 (19) |
| SR achieved during surgery % ( | 80 (20) |
SD standard deviation, SR sinus rhythm.
Fig. 2Survival curve of sinus rhythm maintenance during follow-up. SR sinus rhythm
Studies including patients with (longstanding) persistent atrial fibrillation treated with catheter-guided box isolation
| Study | Number of patients | Follow-up period (months) | % SR maintenance after 1 procedure | % SR maintenance after > 1 procedure |
|---|---|---|---|---|
| Sanders et al. [ | 27 | 24 | 44 | 63 |
| Chen et al. [ | 24 | 12 | 50 | – |
| Kumagai et al. [ | 24 | 12 | 46 | – |
SR sinus rhythm.