Haemovigilance of reactions associated with red blood cell transfusion: comparison across 17 Countries.

M A M Rogers1,2, J M Rohde1, N Blumberg3.   

Abstract

BACKGROUND AND OBJECTIVES: The recent establishment of the National Healthcare Safety Network Hemovigilance Module in the United States affords an opportunity to compare results with those of other developed nations.
MATERIALS AND METHODS: Using data from national haemovigilance systems, reactions associated with red blood cell (RBC) transfusion and residual risks of transfusion-transmitted infectious diseases were assembled from 17 nations. Country-specific rates of adverse events were pooled using random-effects Poisson regression.
RESULTS: Febrile non-haemolytic and delayed serologic transfusion reactions were the most frequent adverse events reported after RBC transfusion, occurring in 26 patients per 100 000 RBC units and 25 patients per 100 000 RBC units administered, respectively. Rates of allergic, febrile non-haemolytic and delayed haemolytic transfusion reactions in the United States were significantly greater than the pooled rates from other countries. Frequencies of adverse events generated from the national haemovigilance programme in the United States were considerably lower than when obtained through active surveillance.
CONCLUSION: Haemovigilance reports of adverse events in the United States are comparable to, or greater than, reports from other developed countries. Rates generated from haemovigilance programmes are lower than those obtained through active surveillance. The lack of universal leucoreduction of RBC units may be a contributing factor to the higher rate of some adverse events in the United States.
© 2015 International Society of Blood Transfusion.

Entities:  

Keywords:  adverse reaction; haemovigilance; international; transfusion

Mesh:

Year:  2015        PMID: 26689441      PMCID: PMC7169273          DOI: 10.1111/vox.12367

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


Introduction

First established in France and Japan in 1993 as a response to the vulnerability of the blood supply after the emergence of HIV 1, 2, haemovigilance systems aim to improve the safety of the blood supply through systematic surveillance of transfusion‐related adverse events. Such systems generate recommendations so as to encourage safety throughout the entire process, from blood donation through monitoring of recipients. Several directives from the European Union relate to the regulation, monitoring and safety of blood products, with the haemovigilance component helping to direct member nations’ reporting of serious transfusion‐related adverse reactions and events 3. Therefore, haemovigilance systems are widespread in European nations, with prime examples being the United Kingdom with its voluntary Serious Hazards of Transfusion reporting system (99·5% participation in 2013) 4, and the Netherlands with its Transfusion and Transplantation Reactions in Patients haemovigilance programme (98% participation in 2013) 5. The USA opened its first nationwide haemovigilance system in 2010 as a voluntary module of the National Healthcare Safety Network 6. Results from this new system are now available and can be compared with existing haemovigilance programmes. As more nations begin to implement haemovigilance programmes, an assessment of the abilities of national systems to report reactions and a comparative review of event rates can be informative.

Methods

Haemovigilance data on transfusion‐related adverse reactions and transfusion‐transmitted infections were available from the national haemovigilance systems in each of the following countries: Australia 7, Canada 8, Denmark 9, Finland 10, France 11, Germany 12, Ireland 13, Japan 14, 15, 16, the Netherlands 5, New Zealand 17, Norway 18, Portugal 19, 20, Spain 21, Sweden 22, Switzerland 23, United Kingdom4 and the USA 6. Data regarding adverse events after RBC transfusion were collected: allergic reactions, anaphylactic reactions, febrile non‐haemolytic transfusion reactions (FNHTR), acute and delayed haemolytic transfusion reactions, hypotensive reactions, transfusion‐related acute lung injury (TRALI), transfusion‐associated dyspnoea, transfusion‐associated circulatory overload (TACO), delayed serologic transfusion reactions, post‐transfusion purpura and transfusion‐transmitted bacterial sepsis. Some countries reported additional categories and these were included as well (acute transfusion‐related pain, haemosiderosis). For each country, data from the most recently available report were utilized. Risks of transfusion‐transmitted viruses were available for agents with mandated testing. Reporting methods differ by country, although in the USA, data regarding residual risk of viral transmission were derived from donor testing since long‐term follow‐up of recipients is not feasible 24. Because it is theoretically possible that a donor could have newly acquired a virus but is sero‐negative at the time of the blood donation, seroconversion rates during this infectious window period are used to predict the residual risk of viral infection 24.

Statistical analyses

Rates of non‐infectious adverse events were calculated for each country using the number of events (numerator) and the number of RBC units administered (denominator). Rates were reported for each country as events per 100 000 RBC units for non‐infectious adverse events and events per million RBC units for infectious adverse events. Canada and Spain were exceptions; adverse events were recorded for components combined (RBCs, platelets, plasma). In the USA, TACO was the only event in which reporting was performed for components combined (RBCs, platelets, plasma). In secondary analyses, adverse event rates from active surveillance in the USA were compared with the rates generated from the passive haemovigilance programme; in these instances, the rates were given using several denominators (per patient, per unit and per transfusion‐related hospital stay). Following current recommendations for summarizing rates 25, random‐effects Poisson regression models were generated to pool rates of transfusion‐related adverse events with 95% confidence intervals. That is, the numbers of events were fit to a Poisson distribution with the number of RBC units included as an offset. Countries that reported zero events were included and, in such instances, a one‐sided exact Poisson 97·5% confidence interval was used for the country‐specific rate. Heterogeneity was assessed using a gamma density function (shape parameter = 2, scale = 0·5) for the variance of the random intercept (between‐country variance) in the Poisson model. This Rate Index of Heterogeneity (RIH) is unit‐independent, encompasses a range from 0% to 100% heterogeneity and is directly derived from the underlying random‐effects Poisson model for assessment of rates. Analyses were conducted using Stata/MP 13·1 (College Station, Texas, USA).

Results

Allergic reactions after RBC transfusion occurred in 11 patients per 100 000 RBC units administered (95% CI: 6·55/100 000 to 18·08/100 000) with a RIH of 58·5% (Fig. 1). The rate of allergic reactions in the USA was significantly greater (53·61/100 000; 95% CI: 49·59/100 000–57·87/100 000) than the pooled rate of the other developed countries combined (9·7/100 000; 95% CI: 5·93/100 000–15·85/100 000). Some countries reported anaphylactic reactions separately and these occurred at a lower rate of 0·9 per 100 000 RBC units (RIH = 17·1%). In the United Kingdom, acute transfusion reactions were defined as instances of anaphylaxis or severe allergic reactions, severe febrile reactions, severe hypotensive reactions and severe mixed reactions; these occurred at a rate of nine patients per 100 000 RBC units.
Figure 1

Rates of allergic reactions in haemovigilance reports, by Country.

Rates of allergic reactions in haemovigilance reports, by Country. There was variability in the rates of FNHTR across countries (RIH = 94·0%). Overall, the rate was 26 patients per 100 000 RBC units, although the Netherlands, New Zealand and the USA recorded rates in excess of 100 patients per 100 000 RBC units, or approximately one in one‐thousand units (Fig. 2). The rate of FNHTR in the USA was significantly greater (106·32/100 000; 95% CI: 100·63/100 000–112·25/100 000) than the pooled rate of the other developed countries combined (22·85/100 000; 95% CI: 9·74/100 000–53·63/100 000). Hypotensive reactions after RBC transfusion occurred less frequently, in 2 patients per 100 000 RBC units (RIH = 34·3%). In Spain, hypotensive reactions were combined with FNHTR, yielding a rate of 48 patients in 100 000 RBC units.
Figure 2

Rates of acute transfusion reactions in haemovigilance reports, by Country.

Rates of acute transfusion reactions in haemovigilance reports, by Country. Acute transfusion‐related pain was reported separately in the Swedish haemovigilance system, occurring in one patient per 100 000 RBC units (Fig. 2). Rates of acute and delayed haemolytic transfusion reactions are shown in Fig. 3. Acute haemolytic transfusion reactions occurred in 1 patient per 100 000 RBC units administered (RIH = 8·3%), while a delayed haemolytic transfusion reaction occurred in approximately two patients per 100 000 RBC units (RIH = 37·6%). In Germany, Spain and the United Kingdom, both acute and delayed haemolytic transfusion reactions were combined, yielding a pooled rate of 1·4/100 000 units (RIH = 57·0%). Both Ireland and the USA tended to have delayed haemolytic transfusion reactions at a greater frequency than other countries, although the confidence intervals for Ireland were wide indicating fewer RBC units due to a smaller population. The rate of delayed haemolytic transfusion reactions in the USA was significantly greater (6·94/100 000; 95% CI: 5·54/100 000–8·58/100 000) than the pooled rate of the other developed countries combined (1·6/100 000; 95% CI: 0·9/100 000–2·8/100 000).
Figure 3

Rates of haemolytic reactions in haemovigilance reports, by Country.

Rates of haemolytic reactions in haemovigilance reports, by Country. Respiratory reactions to RBC transfusion are shown in Fig. 4. Transfusion‐associated dyspnoea was reported in two patients per 100 000 RBC units (RIH = 77·4%). New Zealand was an outlier in this category. TRALI associated with RBC units was quite low (Fig. 4), at a pooled rate of 0·35 per 100 000 RBC units (RIH = 73·2%).
Figure 4

Rates of respiratory transfusion reactions in haemovigilance reports, by Country.

Rates of respiratory transfusion reactions in haemovigilance reports, by Country. TACO occurred in approximately three patients for each 100 000 RBC units transfused, although there was some variation in rates across countries (Fig. 5; RIH = 76·9%). Haemosiderosis was reported separately in France and Spain and occurred at a rate of 0·3 for every 100 000 units transfused (RIH = 99·6%).
Figure 5

Rates of circulatory overload in haemovigilance reports, by Country.

Rates of circulatory overload in haemovigilance reports, by Country. The results for delayed serologic transfusion reactions are given in Fig. 6, showing heterogeneity across countries (RIH = 91·5%; rate = 24·6/100 000 units), with elevated rates in the Netherlands and Switzerland. Post‐transfusion purpura occurred rarely, at a rate of 0·08 per 100 000 RBC units administered (Fig. 6; RIH = 0%). Other transfusion‐related reactions, as shown in Fig. 6, varied by country and were not described in great detail in the country‐specific annual reports.
Figure 6

Rates of other transfusion reactions in haemovigilance reports, by Country.

Rates of other transfusion reactions in haemovigilance reports, by Country. Documented cases of transfusion‐transmitted bacterial sepsis occurred rarely, approximately once in every million RBC units administered (Fig. 7; RIH = 57·8%).
Figure 7

Rates of transfusion‐transmitted bacterial sepsis in haemovigilance reports, by Country.

Rates of transfusion‐transmitted bacterial sepsis in haemovigilance reports, by Country. Table 1 displays the estimate residual risk of viral transmission due to RBC transfusion. Rates were very low. HIV and hepatitis B and C viruses were most often monitored through haemovigilance, while data regarding other viruses (cytomegalovirus, Epstein–Barr, etc.) were available from only a few countries.
Table 1

Risk of transfusion‐transmitted viruses in haemovigilance reports, by Country

VirusCountryYearsRate
CytomegalovirusFrance20091 in 1·5 million
The Netherlands2012<1 in 620 000
Norway2004–20101 in 1·4 million
Epstein–Barr VirusThe Netherlands2012<1 in 620 000
Hepatitis A VirusFrance2009<1 in 3 million
The Netherlands2012<1 in 620 000
Norway2004–20101 in 1·4 million
Hepatitis B VirusAustralia2012–20131 in 720 000
Canada2006–20091 in 1·7 million
Denmark20091 in 270 000
Finland2007<1 in 450 000
France2009<1 in 3 million
Germany20101 in 6·1 million
Ireland2010–2011<1 in 190 000
Japan20121 in 880 000
The Netherlands2012<1 in 620 000
New Zealand20131 in 68 000
Spain20131 in 1·9 million
Switzerland20131 in 400 000
UK20131 in 2·8 million
USA2006–20081 in 300 000
Hepatitis C VirusAustralia2012–2013<1 in 1 million
Canada2006–20091 in 6·7 million
Denmark2009<1 in 540 000
Finland2007<1 in 450 000
France2009<1 in 3 million
Germany2010<1 in 6·1 million
Ireland2010–2011<1 in 190 000
The Netherlands2012<1 in 620 000
Sweden2013<1 in 460 000
Switzerland20131 in 6·7 million
UK2013<1 in 2·8 million
USA2007–20081 in 1·1 million
Hepatitis E VirusFrance2009<1 in 3 million
Japan20121 in 1·3 million
UK20131 in 2·8 million
Human Immunodeficiency VirusAustralia2012–2013<1 in 1 million
Canada2006–20091 in 8 million
Denmark2009<1 in 540 000
Finland2007<1 in 450 000
France2009<1 in 3 million
Germany20101 in 6·1 million
Ireland2010–2011<1 in 190 000
The Netherlands2012<1 in 620 000
New Zealand2013<1 in 140 000
Switzerland20131 in 4·1 million
UK2013<1 in 2·8 million
USA2007–20081 in 1·5 million
Human T‐Lymphotropic VirusAustralia2012–2013<1 in 1 million
The Netherlands2012<1 in 620 000
USA2000–20011 in 2·1 million
Parvovirus B19France20091 in 3 million
The Netherlands2012<1 in 620 000
Norway2004–20101 in 1·4 million
Varicella Zoster VirusNorway2004–20101 in 1·4 million
Risk of transfusion‐transmitted viruses in haemovigilance reports, by Country Rates of adverse reactions in the USA, as generated through haemovigilance, were compared to documented rates obtained through active surveillance. Published frequency rates of TACO are shown in Table 2 26, 27, 28, 29, 30, 31, 32. When units were used as the denominator, the pooled rate of TACO was 368 per 100 000 units or one in every 271 units from active surveillance. This compares with one in 10942 units from passive surveillance through the haemovigilance programme in the USA.
Table 2

Incidence of transfusion‐associated circulatory overload in the United States

Author, yearSourceType of studyIncidenceIncidenceComponentsYear
Frequency per patient
Popovsky 26, 19965 Massachusetts hospitals, total hip or knee replacementsRetrospective cohort1·0% of patients1 in 95 patientsAll1992–1993
Bierbaum 27, 1999235 hospitals, total hip or knee arthroplastyProspective cohort8·0% of patients1 in 12 patientsAll1996–1997
Rana 28, 2006Mayo Clinic, intensive care unitsProspective cohort1·85% of patients1 in 54 patientsAll2003
Li 29, 2011Mayo Clinic, medical intensive care unitProspective cohort5·7% of patients1 in 18 patientsAll2 years, before 2007
Andrzejewski 30, 2012Hospital in Massachusetts, all agesRetrospective cohort0·6% of patients1 in 166 patientsRBCs2005–2008
Clifford 31, 2015Mayo Clinic, adults, non‐cardiac surgeryRetrospective cohort5·5% of patients1 in 18 patientsAll2004
3·0% of patients1 in 33 patientsAll2011
Frequency per unit:
Rana 28, 2006Mayo Clinic, intensive care unitsProspective cohort281/100 000 units1 in 356 unitsAll2003
Andrzejewski 30, 2012Hospital in Massachusetts, all agesRetrospective cohort189/100 000 units1 in 530 unitsRBCs2005–2008
Harvey 6, 2014National Healthcare Safety Network, 77 facilitiesVoluntary haemovigilance9/100 000 units1 in 10942 unitsAll2010–2012
Clifford 31, 2015Mayo Clinic, adults, non‐cardiac surgeryRetrospective cohort4000/100 000 units1 in 25 unitsRBCs2004
1087/100 000 units1 in 92 unitsRBCs2011
Frequency per hospital stay
Menis 32, 2014Medicare administrative databaseRetrospective0·06% of stays1 in 1602 staysAll2011
Incidence of transfusion‐associated circulatory overload in the United States In general, rates of FNHTR were lower in leucoreduced versus non‐leucoreduced products within the same population (Table 3) 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44. With prospective surveillance, the pooled rate of FNHTR was 1191/100 000 units or one in every 84 units; this compares with one case in 3885 RBC units from haemovigilance. The rates tended to be greater in children than adults; one in 20 children who received a transfusion developed FNHTR (all component types combined). FNHTR rates also appeared higher in patients with cancer.
Table 3

Incidence of febrile non‐haemolytic transfusion reaction in the United States

Author, yearSourceType of studyIncidenceIncidenceComponentsYear
Frequency per patient
Paglino 33, 2004Yale‐New Haven Hospital, Connecticut, all agesRetrospective cohort1·33% of patients1 in 75 patients25% leucoreduced RBCs1995–1998
0·79% of patients1 in 127 patients99% leucoreduced RBCs2000–2002
Sanders 34, 2005St. Jude Children's Research HospitalRetrospective cohort4·94% of children1 in 20 childrenAll2002
Kennedy 35, 2008Wake Forest University, Comprehensive Cancer CenterProspective active surveillance8·70% of patients1 in 11 patientsRBCs and PLTs, leucoreduced1993–1997
Frequency per unit
Menitove 36, 198233 Hospitals in South‐eastern Wisconsin, all agesRetrospective cohort478/100 000 units1 in 209 unitsRBCs and whole blood1980
Dzieczkowski 37, 1995Dana‐Farber Cancer Institute, Boston, MassachusettsProspective cohort2147/100 000 units1 in 47 unitsRBCs, leucoreduced after storage1993
Federowicz 38, 1996Dana‐Farber Cancer Institute, Boston, MassachusettsProspective cohort1109/100 000 units1 in 90 unitsRBCs, leucoreduced before storageBefore 1995
Uhlman 39, 2001Barnes‐Jewish Hospital, St. Louis, MissouriRetrospective cohort124/100 000 units1 in 809 unitsNon‐leucoreduced RBCs1999
81/100 000 units1 in 1238 unitsLeucoreduced RBCs2000
Domen 40, 2003Cleveland Clinic, Ohio, all agesRetrospective cohort30/100 000 units1 in 3293 unitsRBCs1993–2001
Paglino 33, 2004Yale‐New Haven Hospital, Connecticut, all agesRetrospective cohort340/100 000 units1 in 294 units25% leucoreduced RBCs1995–1998
180/100 000 units1 in 556 units99% leucoreduced RBCs2000–2002
King 41, 2004The Johns Hopkins Hospital, all agesRetrospective cohort369/100 000 units1 in 271 units4% leucoreduced RBCs1994
186/100 000 units1 in 538 units99·5% leucoreduced RBCs2001
Ezidiegwu 42, 2004State University of New York, Syracuse, adults, nonsurgicalRetrospective cohort162/100 000 units1 in 619 unitsRBCs1998–2000
79/100 000 units1 in 1259 unitsLeucoreduced RBCs2001–2002
Sanders 34, 2005St. Jude Children's Research HospitalRetrospective cohort360/100 000 units in children1 in 278 units in childrenRBCs2002
Kennedy 35, 2008Wake Forest University, Comprehensive Cancer CenterProspective active surveillance639/100 000 units1 in 156 unitsRBCs and PLTs, leucoreduced1993–1997
Harvey 6, 2014National Healthcare Safety Network, 77 facilitiesVoluntary haemovigilance106/100 000 units1 in 941 unitsRBCs2010–2012
Oakley 43, 2015Vanderbilt University Medical Center, all agesRetrospective cohort184/100 000 units in children1 in 545 units in childrenLeucoreduced RBCs2011–2013
36/100 000 units in adults1 in 2775 units in adultsLeucoreduced RBCs2011–2013
Frequency per hospital stay
Menis 44, 2015Medicare administrative databaseRetrospective0·07% of stays1 in 1419 staysRBCs2011–2012
Incidence of febrile non‐haemolytic transfusion reaction in the United States

Discussion

Haemovigilance systems in developed nations report low rates of adverse events after RBC transfusion. For anaphylaxis, hypotension and purpura, the rates were quite consistent across countries. Rates of some reactions, however, were notably elevated in particular countries. Rates of allergic reactions were higher in the USA and New Zealand; rates of FNHTR were elevated in the USA, the Netherlands and New Zealand; and TACO was more commonly reported in Canada, France, Ireland, the Netherlands and the USA. New Zealand reported a greater rate of transfusion‐associated dyspnoea in 2013. However, in a recent report, more than half of the dyspnoea cases were reclassified when additional information was retrieved (many being reclassified as TACO) 45. Overall, TACO occurred at a rate of three cases per 100 000 units when pooled from haemovigilance reports, with the incidence of TACO in the USA alone being one in 10942 units. However, based on active surveillance studies from the USA, 0·6% to 8% of patients receiving RBC transfusions develop TACO. This disparity between active and passive surveillance rates may stem from insufficient reporting of reactions to haemovigilance systems. For example, researchers from the Mayo Clinic noted that there were 176 cases of TACO in their investigation but only three were in the transfusion database that housed adverse reactions – and even then, these three cases were not labelled as TACO 31. Given the more comprehensive monitoring of fever after RBC transfusion, the variability of rates of FNHTR across countries may be a reflection of dissimilarities in patient populations, differential use of pretransfusion antipyretic medications or the preparation of RBC units. Of note, the USA has not adopted universal leucoreduction (70·5% RBC units leucoreduced in 2011)46 and FNHTR has been reported more frequently in patients receiving non‐leucoreduced products 33, 39, 41, 42, 47. FNHTR rates in the USA are higher than the pooled FNHTR rates in other developed countries and the use of non‐leucoreduced products could partially account for these findings. The variability in rates of allergic reactions across nations may stem from differences in case definitions. In Australia, for example, a severe allergic reaction would be recorded if rash, allergic dyspnoea, angioedema, generalized pruritis or uticaria occurred within 24 h of the transfusion 7. In the USA, a severe allergic reaction would be recorded if two or more symptoms (conjunctival oedema; oedema of lips, tongue and uvula; erythema and oedema of the periorbital area; generalized flushing; hypotension; localized angioedema; maculopapular rash; pruritus; respiratory distress or bronchospasm; urticaria) occurred during or within 4 h of the cessation of transfusion 48. Moreover, in some countries such as New Zealand, both non‐severe and severe allergic reactions are reported17 (perhaps reflecting their higher rates as shown in Fig. 1) while in the USA, reporting of non‐severe allergic reactions is not required 48. Other reasons for differences in rates may be variations in hospital‐specific reporting practices and the mandatory/voluntary nature of the reporting. For events such as delayed serologic transfusion reaction and delayed haemolytic transfusion reaction, the definition hinges on laboratory testing and not symptoms. Rate differences may be a reflection of the resources afforded for testing of alloantibodies and the feasibility of longitudinal observation. Information regarding follow‐up procedures or standardization of procedures would enhance the interpretability of rates. Alternatively, haemovigilance programmes may reconsider the usefulness of expending resources to capture such data when the likelihood of consistent, meaningful information is low. Perhaps periodic systematic testing in high users of transfusion would be more appropriate such as in patients with sickle‐cell disease or cancer, or in participants of cardiovascular disease registries. Results from this investigation indicate that the residual risks from currently tested infectious agents are very low and, in many instances, could be considered negligible. However, it is the potential risks from other infectious agents (not yet tested) which are more pertinent at this time. These include vCJD, hepatitis E virus, dengue viruses, chikungunya virus, Babesia spp., West Nile virus and Middle East respiratory syndrome coronavirus – although the list of potential threats includes approximately 70 such agents 49. For example, in the USA, transfusion‐transmitted babesiosis has been documented in more than 200 instances and is associated with the greatest case fatality rate of transfusion‐related infections 50. Haemovigilance for transfusion‐transmitted infection is meant to capture pathogen transmission from donor to recipient. The requirements include the demonstration of the pathogen in the transfused component, or in the donor at the time of donation, or in an additional component from the same donation, or in an additional recipient of a component from the same donation 48. Also required is documentation that there are no other potential exposures to the pathogen that could be identified in the recipient and either evidence that the recipient was not infected with the pathogen prior to transfusion or evidence that the pathogen strains are related by molecular or extended phenotypic comparison testing 48. This is a difficult target to reach when such in‐depth testing is not usually conducted with each transfusion. Therefore, the pooled rate of transfusion‐transmitted bacterial sepsis was very low (0·83/1 million RBC units). There are few published reports of prospective surveillance for comparison purposes. Barrett and colleagues51 found a bacterial contamination rate of 3·2/100 000 RBC units, while Dzieczkowski and colleagues37 reported this rate to be 14·1/100 000 RBC units. In a more recent report from Denmark, 35% of RBC units contained viable bacteria which were obtained from donors 50 years of age or older 52. There are avenues for improvement in existing haemovigilance systems. The addition of active surveillance components may enhance reporting. Expansion of electronic medical records to incorporate more information regarding blood administration may augment comprehensiveness. Adjunct programming routines could be enacted to capture pre‐ and post‐transfusion temperatures so that detection of FNHTR could be improved. Likewise, electronic capture of pre‐ and post‐transfusion blood pressures could assist the detection of hypotensive reactions. Some have already merged records from transfusion and apheresis medicine with the main electronic medical record 53, 54, 55. The SCANDAT2 is a successful example of linked donor and recipient health information in Sweden and Denmark 55. In addition, international networks (e.g. International Haemovigilance Network 56, Global Vigilance and Surveillance Database for Medical Products of Human Origin 57, World Health Organization Global Database on Blood Safety58) provide opportunities for surveillance and the improvement of blood safety. National haemovigilance programmes afford an important aspect of patient safety. Such systems generally capture serious transfusion reactions but, with improvement, could generate more comprehensive information. Cross‐country comparisons can provide the basis for discovery and continuous process improvement.
  32 in total

1.  Prestorage universal WBC reduction of RBC units does not affect the incidence of transfusion reactions.

Authors:  E J Uhlmann; E Isgriggs; M Wallhermfechtel; L T Goodnough
Journal:  Transfusion       Date:  2001-08       Impact factor: 3.157

2.  Febrile non-haemolytic transfusion reaction occurrence and potential risk factors among the U.S. elderly transfused in the inpatient setting, as recorded in Medicare databases during 2011-2012.

Authors:  M Menis; R A Forshee; S A Anderson; S McKean; R Gondalia; R Warnock; C Johnson; P D Mintz; C M Worrall; J A Kelman; H S Izurieta
Journal:  Vox Sang       Date:  2014-12-03       Impact factor: 2.144

3.  Transfusion-associated dyspnea--shadow or substance?

Authors:  K G Badami; E Joliffe; M Stephens
Journal:  Vox Sang       Date:  2015-04-08       Impact factor: 2.144

4.  Strategies for the avoidance of bacterial contamination of blood components.

Authors:  B B Barrett; J W Andersen; K C Anderson
Journal:  Transfusion       Date:  1993-03       Impact factor: 3.157

5.  Transfusion-related acute lung injury and pulmonary edema in critically ill patients: a retrospective study.

Authors:  Rimki Rana; Evans R Fernández-Pérez; S Anjum Khan; Sameer Rana; Jeffrey L Winters; Timothy G Lesnick; S Breanndan Moore; Ognjen Gajic
Journal:  Transfusion       Date:  2006-09       Impact factor: 3.157

6.  Transfusion-associated circulatory overload in orthopedic surgery patients: a multi-institutional study.

Authors:  M A Popovsky; A M Audet; C Andrzejewski
Journal:  Immunohematology       Date:  1996

7.  A prospective, randomized, double-blind controlled trial of acetaminophen and diphenhydramine pretransfusion medication versus placebo for the prevention of transfusion reactions.

Authors:  LeAnne D Kennedy; L Douglas Case; David D Hurd; Julia M Cruz; Gregory J Pomper
Journal:  Transfusion       Date:  2008-07-30       Impact factor: 3.157

8.  Hemotherapy bedside biovigilance involving vital sign values and characteristics of patients with suspected transfusion reactions associated with fluid challenges: can some cases of transfusion-associated circulatory overload have proinflammatory aspects?

Authors:  Chester Andrzejewski; Mark A Popovsky; Theresa C Stec; Jean Provencher; Lynne O'Hearn; Paul Visintainer; Jay Steingrub
Journal:  Transfusion       Date:  2012-03-12       Impact factor: 3.157

9.  Reduction of febrile but not allergic reactions to RBCs and platelets after conversion to universal prestorage leukoreduction.

Authors:  Justin C Paglino; Gregory J Pomper; Gene S Fisch; Melanie H Champion; Edward L Snyder
Journal:  Transfusion       Date:  2004-01       Impact factor: 3.157

10.  Current perspectives in transfusion-transmitted infectious diseases: emerging and re-emerging infections.

Authors:  S L Stramer
Journal:  ISBT Sci Ser       Date:  2014-07-28
View more
  6 in total

1.  Incidence and risk factors of transfusion reactions in postpartum blood transfusions.

Authors:  Lars Thurn; Agneta Wikman; Magnus Westgren; Pelle G Lindqvist
Journal:  Blood Adv       Date:  2019-08-13

2.  Incidence and clinical characteristics of transfusion-associated circulatory overload using an active surveillance algorithm.

Authors:  N H Roubinian; J E Hendrickson; D J Triulzi; J L Gottschall; D Chowdhury; D J Kor; M R Looney; M A Matthay; S H Kleinman; D Brambilla; E L Murphy
Journal:  Vox Sang       Date:  2016-12-21       Impact factor: 2.144

3.  Epidemiology and Associated Factors in Transfusion Management in Intensive Care Unit.

Authors:  Raúl Juárez-Vela; Eva María Andrés-Esteban; Ivan Santolalla-Arnedo; Regina Ruiz de Viñaspre-Hernández; Carmen Benito-Puncel; Ainhoa Serrano-Lázaro; Pilar Marcos-Neira; Alba López-Fernández; Clara Isabel Tejada-Garrido; Juan Luis Sánchez-González; Manuel Quintana-Díaz; José Antonio García-Erce
Journal:  J Clin Med       Date:  2022-06-20       Impact factor: 4.964

4.  Transfusion reactions in pediatric and adolescent young adult haematology oncology and immune effector cell patients.

Authors:  Mira A Kohorst; Sajad J Khazal; Priti Tewari; Demetrios Petropoulos; Benjamin Mescher; Jian Wang; Kris M Mahadeo; James M Kelley
Journal:  EClinicalMedicine       Date:  2020-09-09

Review 5.  Blood Transfusion Reactions-A Comprehensive Review of the Literature including a Swiss Perspective.

Authors:  Theresa Ackfeld; Thomas Schmutz; Youcef Guechi; Christophe Le Terrier
Journal:  J Clin Med       Date:  2022-05-19       Impact factor: 4.964

6.  Incidence of transfusion reactions: a multicenter study utilizing systematic active surveillance and expert adjudication.

Authors:  Jeanne E Hendrickson; Nareg H Roubinian; Dhuly Chowdhury; Don Brambilla; Edward L Murphy; Yanyun Wu; Paul M Ness; Eric A Gehrie; Edward L Snyder; R George Hauser; Jerome L Gottschall; Steve Kleinman; Ram Kakaiya; Ronald G Strauss
Journal:  Transfusion       Date:  2016-07-26       Impact factor: 3.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.