Literature DB >> 26684975

Accurate Quantification Methods for Aortic Insufficiency Severity in Patients With LVAD: Role of Diastolic Flow Acceleration and Systolic-to-Diastolic Peak Velocity Ratio of Outflow Cannula.

Jonathan Grinstein1, Eric Kruse1, Gabriel Sayer1, Savitri Fedson1, Gene H Kim1, Ulrich P Jorde2, Colleen Juricek3, Takeyoshi Ota3, Valluvan Jeevanandam3, Roberto M Lang1, Nir Uriel4.   

Abstract

OBJECTIVES: The aim of this study was to develop a technique to measure regurgitant flow throughout the entire cardiac cycle that would more accurately measure aortic insufficiency (AI) severity in patients with continuous-flow left ventricular assist devices (CF-LVADs).
BACKGROUND: AI is a common problem after CF-LVAD implantation. Current echocardiographic evaluation of AI does not take into account the unique flow properties present in patients with CF-LVADs.
METHODS: In this prospective study, patients with LVADs who had varying degrees of AI (N = 20) underwent simultaneous right-sided heart catheterization (RHC) and transthoracic echocardiography (TTE). Regurgitant fraction (RF) across the aortic valve was calculated by subtracting the cardiac output obtained using the Fick method from the total systemic flow measured using the sum of the product of the velocity time integral and the cross-sectional area of the LVAD outflow cannula and aortic valve, respectively. The RFs were then compared with the following: 1) traditional TTE grading parameters; and 2) new TTE parameters unique to LVAD physiology, namely the diastolic flow acceleration and the systolic-to-diastolic peak velocity (S/D) ratio of the LVAD outflow cannula.
RESULTS: Patients without evidence of AI had an RF approaching zero (2.4 ± 4.6%). Patients with trace and mild AI had an RF of 31.0 ± 5.4%, whereas patients with moderate or severe AI had an RF of 45.8 ± 3.6%. RF correlated better with pulmonary capillary wedge pressure (PCWP) than with vena contracta (correlation coefficient [R] = 0.73 vs. 0.56). The new TTE parameters (S/D ratio and diastolic acceleration) highly correlated with RF (R = 0.91 and 0.94, respectively) and more strongly correlated with PCWP than did vena contracta (R = 0.82 and 0.65 vs. 0.56).
CONCLUSIONS: RF measured by simultaneous RHC and TTE better correlates with clinical filling pressures than do traditional TTE parameters and may identify significant AI that could be underestimated using conventional measures. Novel TTE parameters, unique to CF-LVAD physiology, better correlate with RF and filling pressures than do our current TTE measurements.
Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  LVAD; aortic insufficiency; heart failure

Mesh:

Year:  2015        PMID: 26684975     DOI: 10.1016/j.jcmg.2015.06.020

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  11 in total

Review 1.  Contemporary Perspectives in Durable Mechanical Circulatory Support: What Did We Learn in the Last 3 Years?

Authors:  Jayant Raikhelkar; Nir Uriel
Journal:  Curr Cardiol Rep       Date:  2018-01-29       Impact factor: 2.931

2.  Aortic Insufficiency and Hemocompatibility-related Adverse Events in Patients with Left Ventricular Assist Devices.

Authors:  Teruhiko Imamura; Gene Kim; Daisuke Nitta; Takeo Fujino; Bryan Smith; Sara Kalantari; Ann Nguyen; Nikhil Narang; Luise Holzhauser; Jonathan Grinstein; Colleen Juricek; Daniel Rodgers; Tae Song; Takeyoshi Ota; Valluvan Jeevanandam; Gabriel Sayer; Nir Uriel
Journal:  J Card Fail       Date:  2019-08-13       Impact factor: 5.712

Review 3.  Percutaneous Transcatheter Therapies for the Management of Left Ventricular Assist Device Complications.

Authors:  Rohan J Kalathiya; Jonathan Grinstein; Nir Uriel; Atman P Shah
Journal:  J Invasive Cardiol       Date:  2017-02-15       Impact factor: 2.022

Review 4.  Physiology and Clinical Utility of HeartMate Pump Parameters.

Authors:  Mark N Belkin; Viktoriya Kagan; Colleen Labuhn; Sean P Pinney; Jonathan Grinstein
Journal:  J Card Fail       Date:  2021-12-31       Impact factor: 6.592

5.  Screening for Outflow Cannula Malfunction of Left Ventricular Assist Devices (LVADs) With the Use of Doppler Echocardiography: New LVAD-Specific Reference Values for Contemporary Devices.

Authors:  Jonathan Grinstein; Eric Kruse; Keith Collins; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Nir Uriel; Roberto M Lang
Journal:  J Card Fail       Date:  2016-06-08       Impact factor: 5.712

6.  Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome.

Authors:  Jonathan Grinstein; Eric Kruse; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Roberto M Lang; Nir Uriel
Journal:  J Heart Lung Transplant       Date:  2016-05-20       Impact factor: 10.247

7.  Estimation of the Severity of Aortic Insufficiency by HVAD Flow Waveform.

Authors:  Teruhiko Imamura; Nikhil Narang; Daniel Rodgers; Daisuke Nitta; Takeo Fujino; Sara Kalantari; Bryan Smith; Gene Kim; Ann Nguyen; Ben Chung; Luise Holzhauser; Tae Song; Takeyoshi Ota; Valluvan Jeevanandam; Gabriel Sayer; Nir Uriel
Journal:  Ann Thorac Surg       Date:  2019-11-19       Impact factor: 4.330

8.  Echocardiographic Predictors of Hemodynamics in Patients Supported With Left Ventricular Assist Devices.

Authors:  Jonathan Grinstein; Teruhiko Imamura; Eric Kruse; Sara Kalantari; Daniel Rodgers; Sirtaz Adatya; Gabriel Sayer; Gene H Kim; Nitasha Sarswat; Jayant Raihkelkar; Takeyoshi Ota; Valluvan Jeevanandam; Daniel Burkhoff; Roberto Lang; Nir Uriel
Journal:  J Card Fail       Date:  2018-07-24       Impact factor: 5.712

Review 9.  Hemodynamic Pump-Patient Interactions and Left Ventricular Assist Device Imaging.

Authors:  Nikhil Narang; Jayant Raikhelkar; Gabriel Sayer; Nir Uriel
Journal:  Cardiol Clin       Date:  2018-11       Impact factor: 2.213

Review 10.  Implication of Hemodynamic Assessment during Durable Left Ventricular Assist Device Support.

Authors:  Teruhiko Imamura; Nikhil Narang
Journal:  Medicina (Kaunas)       Date:  2020-08-15       Impact factor: 2.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.