Quantitative histologic study of the influence of spinal instrumentation on lumbar fusions: a canine model.

I D Farey1, P C McAfee, K R Gurr, M A Randolph.   

Abstract

UNLABELLED: Histomorphometric and microradiographic studies were performed on 28 beagle hounds 1 year of age, followed up for 6 months after an L5-L6 anterior and posterior spinal destabilization procedure--Group I (n = 7), destabilized surgical controls; Group II (n = 7), posterolateral bone grafting after destabilization; Group III (n = 7), Harrington rod instrumentation and posterolateral bone grafting after destabilization; and Group IV (n = 7), Luque instrumentation, and bone grafting after destabilization. Six months postoperatively, device-related osteoporosis occurred in spines treated with spinal instrumentation. Within the L5 vertebral body the mean trabecular width was less for the two groups with instrumentation (Groups III and IV) compared with the two groups without instrumentation (Groups I and II) (p less than 0.001). The bone formation rate [mm3/(mm3 x year)] x 10(3), which is based on the mean distance between sequenced fluorochrome labels, for Group I (destabilized, nonfused, noninstrumented dogs) was more than twice that of the other three groups, which were all equivalent (p less than 0.05). CLINICAL RELEVANCE: Stress shielding, or more correctly, device-related osteoporosis, probably can occur within vertebrae in response to rigid spinal instrumentation. However, the overall mechanical properties of vertebrae underlying spinal instrumentation are probably not at increased risk of fracture because the increase in cross-sectional area of the vertebra and incorporated fusion mass more than compensate for the loss of volumetric bone density.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2668473     DOI: 10.1002/jor.1100070512

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Strategies of spinal fusion on osteoporotic spine.

Authors:  Sung Bae Park; Chun Kee Chung
Journal:  J Korean Neurosurg Soc       Date:  2011-06-30

2.  In vitro testing of a new transpedicular stabilization technique.

Authors:  M Pfeiffer; H Hoffman; V K Goel; J N Weinstein; P Griss
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

3.  Evaluation of indication-based use of transpedicular instrumentations with different rigidity for lumbar spinal fusion: a prospective pilot study with 3 years of follow-up.

Authors:  Michael Pfeiffer; Ralph Hildebrand; Michael Grande; Peter Griss
Journal:  Eur Spine J       Date:  2003-02-11       Impact factor: 3.134

4.  Assessing the effects of lumbar posterior stabilization and fusion to vertebral bone density in stabilized and adjacent segments by using Hounsfield unit.

Authors:  Özgür Demir; Erol Öksüz; Fatih Ersay Deniz; Osman Demir
Journal:  J Spine Surg       Date:  2017-12
  4 in total