Literature DB >> 2667285

Stereotactically guided convergent beam irradiation with a linear accelerator: localization-technique.

O Pastyr1, G H Hartmann, W Schlegel, S Schabbert, H Treuer, W J Lorenz, V Sturm.   

Abstract

A stereotactic convergent beam irradiation technique using a linear accelerator has been developed in order to precisely apply single high doses of up to 50 gray and more to brain lesions (radiosurgery). Accurate positioning of the patient and the target point of irradiation is an absolute requirement for this method. The stereotactic localization system developed for this purpose is described.

Entities:  

Mesh:

Year:  1989        PMID: 2667285     DOI: 10.1007/bf01407778

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  9 in total

1.  The stereotaxic method and radiosurgery of the brain.

Authors:  L LEKSELL
Journal:  Acta Chir Scand       Date:  1951-12-13

2.  Stereotactic radiosurgery in intracranial arterio-venous malformations.

Authors:  L Steiner; L Leksell; D M Forster; T Greitz; E O Backlund
Journal:  Acta Neurochir (Wien)       Date:  1974       Impact factor: 2.216

3.  External stereotactic irradiation by linear accelerator.

Authors:  F Colombo; A Benedetti; F Pozza; R C Avanzo; C Marchetti; G Chierego; A Zanardo
Journal:  Neurosurgery       Date:  1985-02       Impact factor: 4.654

4.  Stereotactic computer tomography with a modified Riechert-Mundinger device as the basis for integrated stereotactic neuroradiological investigations.

Authors:  V Sturm; O Pastyr; W Schlegel; H Scharfenberg; H J Zabel; G Netzeband; S Schabbert; W Berberich
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

5.  Radiosurgical treatment of carotid-cavernous fistula.

Authors:  J L Barcia-Salorio; G Herandez; J Broseta; J Gonzalez-Darder; J Ciudad
Journal:  Appl Neurophysiol       Date:  1982

6.  Stereotactic percutaneous single dose irradiation of brain metastases with a linear accelerator.

Authors:  V Sturm; B Kober; K H Höver; W Schlegel; R Boesecke; O Pastyr; G H Hartmann; S Schabbert; K zum Winkel; S Kunze
Journal:  Int J Radiat Oncol Biol Phys       Date:  1987-02       Impact factor: 7.038

7.  Stereotactic heavy-ion Bragg peak radiosurgery for intra-cranial vascular disorders: method for treatment of deep arteriovenous malformations.

Authors:  J I Fabrikant; J T Lyman; Y Hosobuchi
Journal:  Br J Radiol       Date:  1984-06       Impact factor: 3.039

8.  Cerebral radiation surgery using moving field irradiation at a linear accelerator facility.

Authors:  G H Hartmann; W Schlegel; V Sturm; B Kober; O Pastyr; W J Lorenz
Journal:  Int J Radiat Oncol Biol Phys       Date:  1985-06       Impact factor: 7.038

9.  Bragg-peak proton-beam therapy for arteriovenous malformations of the brain.

Authors:  R N Kjellberg; T Hanamura; K R Davis; S L Lyons; R D Adams
Journal:  N Engl J Med       Date:  1983-08-04       Impact factor: 91.245

  9 in total
  3 in total

1.  Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery: Comparison of dosimetric treatment plan quality.

Authors:  Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian Ruge
Journal:  Strahlenther Onkol       Date:  2014-11-22       Impact factor: 3.621

Review 2.  [Stereotactic one-time irradiation (radiosurgery). The methods, indications and results].

Authors:  J Debus; A Pirzkall; W Schlegel; M Wannenmacher
Journal:  Strahlenther Onkol       Date:  1999-02       Impact factor: 3.621

3.  Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

Authors:  L R Schad; M Bock; K Baudendistel; M Essig; J Debus; M V Knopp; R Engenhart; W J Lorenz
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315