Literature DB >> 26661902

Nerve-muscle activation by rotating permanent magnet configurations.

Peter A Watterson1, Graham M Nicholson2.   

Abstract

KEY POINTS: The standard method of magnetic nerve activation using pulses of high current in coils has drawbacks of high cost, high electrical power (of order 1 kW), and limited repetition rate without liquid cooling. Here we report a new technique for nerve activation using high speed rotation of permanent magnet configurations, generating a sustained sinusoidal electric field using very low power (of order 10 W). A high ratio of the electric field gradient divided by frequency is shown to be the key indicator for nerve activation at high frequencies. Activation of the cane toad sciatic nerve and attached gastrocnemius muscle was observed at frequencies as low as 180 Hz for activation of the muscle directly and 230 Hz for curved nerves, but probably not in straight sections of nerve. These results, employing the first prototype device, suggest the opportunity for a new class of small low-cost magnetic nerve and/or muscle stimulators. ABSTRACT: Conventional pulsed current systems for magnetic neurostimulation are large and expensive and have limited repetition rate because of overheating. Here we report a new technique for nerve activation, namely high-speed rotation of a configuration of permanent magnets. Analytical solutions of the cable equation are derived for the oscillating electric field generated, which has amplitude proportional to the rotation speed. The prototype device built comprised a configuration of two cylindrical magnets with antiparallel magnetisations, made to rotate by interaction between the magnets' own magnetic field and three-phase currents in coils mounted on one side of the device. The electric field in a rectangular bath placed on top of the device was both numerically evaluated and measured. The ratio of the electric field gradient on frequency was approximately 1 V m(-2) Hz(-1) near the device. An exploratory series of physiological tests was conducted on the sciatic nerve and attached gastrocnemius muscle of the cane toad (Bufo marinus). Activation was readily observed of the muscle directly, at frequencies as low as 180 Hz, and of nerves bent around insulators, at frequencies as low as 230 Hz. Nerve-muscles, with the muscle elevated to avoid its direct activation, were occasionally activated, possibly in the straight section of the nerve, but more likely in the nerve where it curved up to the muscle, at radius of curvature 10 mm or more, or at the nerve end. These positive first results suggest the opportunity for a new class of small, low-cost devices for magnetic stimulation of nerves and/or muscles.
© 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

Entities:  

Mesh:

Year:  2016        PMID: 26661902      PMCID: PMC4818594          DOI: 10.1113/JP271743

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  25 in total

Review 1.  Transcranial magnetic stimulation in neurology.

Authors:  Masahito Kobayashi; Alvaro Pascual-Leone
Journal:  Lancet Neurol       Date:  2003-03       Impact factor: 44.182

Review 2.  An introduction to the basic principles of magnetic nerve stimulation.

Authors:  A T Barker
Journal:  J Clin Neurophysiol       Date:  1991-01       Impact factor: 2.177

Review 3.  Peripheral nerve stimulation by induced electric currents: exposure to time-varying magnetic fields.

Authors:  J P Reilly
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

4.  The role of tissue heterogeneity in neural stimulation by applied electric fields.

Authors:  Pedro C Miranda; Ludovic Correia; Ricardo Salvador; Peter J Basser
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

5.  A generalized cable equation for magnetic stimulation of axons.

Authors:  S S Nagarajan; D M Durand
Journal:  IEEE Trans Biomed Eng       Date:  1996-03       Impact factor: 4.538

Review 6.  Transcutaneous electrical nerve stimulation: review of effectiveness.

Authors:  Mark Johnson
Journal:  Nurs Stand       Date:  2014-06-10

7.  Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation.

Authors:  P J Maccabee; V E Amassian; L P Eberle; R Q Cracco
Journal:  J Physiol       Date:  1993-01       Impact factor: 5.182

Review 8.  Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research.

Authors:  Simone Rossi; Mark Hallett; Paolo M Rossini; Alvaro Pascual-Leone
Journal:  Clin Neurophysiol       Date:  2009-10-14       Impact factor: 3.708

Review 9.  Reversible nerve conduction block using kilohertz frequency alternating current.

Authors:  Kevin L Kilgore; Niloy Bhadra
Journal:  Neuromodulation       Date:  2013-08-07

10.  A pilot study of the use of EEG-based synchronized Transcranial Magnetic Stimulation (sTMS) for treatment of Major Depression.

Authors:  Yi Jin; Bill Phillips
Journal:  BMC Psychiatry       Date:  2014-01-18       Impact factor: 3.630

View more
  2 in total

1.  Letter to the Editor.

Authors:  Anton Kordić; Vedran Deletis
Journal:  J Physiol       Date:  2016-07-01       Impact factor: 5.182

2.  Reply from Peter A. Watterson and Graham M. Nicholson.

Authors:  Peter A Watterson; Graham M Nicholson
Journal:  J Physiol       Date:  2016-07-01       Impact factor: 5.182

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.