PURPOSE: Different results have been reported on the internal colonization of Cone Morse connections under in vitro dynamic loading. The aim of the present in vitro study was to evaluate the bacterial leakage in Cone Morse implant-abutment connections, both under loaded and unloaded conditions.
METHODS: A total of 20 implants with a Cone Morse taper internal connection were used in this study. Ten were loaded under a special testing equipment (Test Group), while 10 were left unloaded (Control Group). The inner part of all implants was inoculated with 0.1 μl of a viable Enterococcus faecalis suspension. A force of 120 N was applied to the loaded implants, for a total of 500,000 cycles at 1 Hz. All the samples were checked daily, for a total of 14 days, and presence or absence of turbidity recorded.
RESULTS: In the unloaded assemblies, bacterial contamination was found in 2 out of 10 implant-abutment junctions, on the 12th and 13th days. In the loaded implant-abutment connections, bacterial contamination was found in 2 out of 10 implant-abutment assemblies, on the 13th and on the 14th days.
CONCLUSIONS: The resistance of the Cone Morse implant-abutment junction reported in the literature and confirmed in the present study, where no differences in the percentages of microbial leakage were found in assemblies unloaded and in those subjected to a dynamic loading procedure, could help to explain the histological results in man of a lack of peri-crestal bone resorption in Cone Morse implants, placed below the level of the alveolar crest.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26660625     DOI: 10.5301/jabfm.5000247

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  8 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection.

Authors:  Hooman Khorshidi; Saeed Raoofi; Afagh Moattari; Atoosa Bagheri; Mohammad Hassan Kalantari
Journal:  Int J Biomater       Date:  2016-05-03

3.  The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study.

Authors:  Mehrak Amjadi; Azadeh Khajavi; Navid Youssefi; Negar Barjini; Zahra Kazemi
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

4.  Bacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns.

Authors:  Peter Gehrke; Simon Burg; Ulrike Peters; Thomas Beikler; Carsten Fischer; Frank Rupp; Ernst Schweizer; Paul Weigl; Robert Sader; Ralf Smeets; Sogand Schäfer
Journal:  Clin Oral Investig       Date:  2021-08-16       Impact factor: 3.573

5.  Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study.

Authors:  Simonetta D'Ercole; Tatiane Cristina Dotta; Marzieh Ramezani Farani; Niloofar Etemadi; Giovanna Iezzi; Luca Comuzzi; Adriano Piattelli; Morena Petrini
Journal:  Bioengineering (Basel)       Date:  2022-06-26

6.  Bacterial infiltration and detorque at the implant abutment morse taper interface after masticatory simulation.

Authors:  Ana Paula Granja Scarabel Nogueira Bella; Alessandra Sayuri Tuzita; Ivana Barbosa Suffredini; Alberto Noriyuki Kojima; Elcio Magdalena Giovani; Alfredo Mikail Melo Mesquita
Journal:  Sci Rep       Date:  2022-10-12       Impact factor: 4.996

7.  Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections.

Authors:  Hakimeh Siadat; Hossain Najafi; Marzieh Alikhasi; Babak Falahi; Elaheh Beyabanaki; Farid Zayeri
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18

8.  Comparative study of bacterial microfiltration in the implant-abutment interface, with straight and conical internal connections, in vitro.

Authors:  Larrucea V Carlos; Navarro C Carlos; Larrucea Sm Karina; Boda K Sunil; Padilla E Carlos; Lobos G Olga
Journal:  Clin Exp Dent Res       Date:  2021-06-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.