Literature DB >> 26656192

Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users.

Lidwien C E Veugen1, Josef Chalupper, Ad F M Snik, A John van Opstal, Lucas H M Mens.   

Abstract

OBJECTIVES: The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree.
DESIGN: Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and >1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings.
RESULTS: Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit insignificantly by 0.6 dB when noise was presented from the CI implanted side, or by 0.8 (single-talker noise) and 1.1 dB (stationary noise) in the more complex configurations with two simultaneous maskers from both sides. In questionnaires, subjects rated the AGC-matched HA higher than the standard HA for understanding of one person in quiet and in noise, and for the quality of sounds. Listening to a slightly raised voice, subjects indicated increased listening comfort with matched AGCs. At the end of the study, 9 of 15 subjects preferred to take home the AGC-matched HA, 1 preferred the standard HA and 5 subjects had no preference.
CONCLUSION: For bimodal listening, the AGC-matched HA outperformed the standard HA in speech understanding in noise tasks using a single competing talker and it was favored in questionnaires and in a subjective preference test. When noise was presented from the HA side, AGC matching resulted in a 1.9 dB SNR additional benefit, even though the HA was at the least favorable SNR side in this speaker configuration. Our results possibly suggest better binaural processing for matched AGCs.

Entities:  

Mesh:

Year:  2016        PMID: 26656192     DOI: 10.1097/AUD.0000000000000260

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  13 in total

1.  The Effect of Binaural Beamforming Technology on Speech Intelligibility in Bimodal Cochlear Implant Recipients.

Authors:  Jantien L Vroegop; Nienke C Homans; André Goedegebure; J Gertjan Dingemanse; Teun van Immerzeel; Marc P van der Schroeff
Journal:  Audiol Neurootol       Date:  2018-06-22       Impact factor: 1.854

2.  Bimodal Cochlear Implant Listeners' Ability to Perceive Minimal Audible Angle Differences.

Authors:  Ashley Zaleski-King; Matthew J Goupell; Dragana Barac-Cikoja; Matthew Bakke
Journal:  J Am Acad Audiol       Date:  2018-11-12       Impact factor: 1.664

Review 3.  Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf.

Authors:  Sabrina H Pieper; Noura Hamze; Stefan Brill; Sabine Hochmuth; Mats Exter; Marek Polak; Andreas Radeloff; Michael Buschermöhle; Mathias Dietz
Journal:  Trends Hear       Date:  2022 Jan-Dec       Impact factor: 3.496

Review 4.  Bimodal Hearing in Individuals with Severe-to-Profound Hearing Loss: Benefits, Challenges, and Management.

Authors:  Sarah E Warren; M Noelle Dunbar
Journal:  Semin Hear       Date:  2018-10-26

5.  The Benefits of Bimodal Aiding on Extended Dimensions of Speech Perception: Intelligibility, Listening Effort, and Sound Quality.

Authors:  Elke M J Devocht; A Miranda L Janssen; Josef Chalupper; Robert J Stokroos; Erwin L J George
Journal:  Trends Hear       Date:  2017 Jan-Dec       Impact factor: 3.293

6.  Self-Reported Usage, Functional Benefit, and Audiologic Characteristics of Cochlear Implant Patients Who Use a Contralateral Hearing Aid.

Authors:  Arlene C Neuman; Susan B Waltzman; William H Shapiro; Jonathan D Neukam; Annette M Zeman; Mario A Svirsky
Journal:  Trends Hear       Date:  2017-01       Impact factor: 3.293

7.  Effectiveness and efficiency of a dedicated bimodal fitting formula.

Authors:  Domenico Cuda; Alessandra Murri; Anna Mainardi; Josef Chalupper
Journal:  Audiol Res       Date:  2019-05-09

8.  Integrated Bimodal Fitting for Unilateral CI Users with Residual Contralateral Hearing.

Authors:  Gennaro Auletta; Annamaria Franzè; Carla Laria; Carmine Piccolo; Carmine Papa; Pasquale Riccardi; Davide Pisani; Angelo Sarnelli; Valeria Del Vecchio; Rita Malesci; Elio Marciano
Journal:  Audiol Res       Date:  2021-05-12

9.  Hearing aid fitting for visual and hearing impaired patients with Usher syndrome type IIa.

Authors:  B P Hartel; M J H Agterberg; A F Snik; H P M Kunst; A J van Opstal; A J Bosman; R J E Pennings
Journal:  Clin Otolaryngol       Date:  2016-11-06       Impact factor: 2.597

10.  Real-time loudness normalisation with combined cochlear implant and hearing aid stimulation.

Authors:  Dimitar Spirrov; Maaike Van Eeckhoutte; Lieselot Van Deun; Tom Francart
Journal:  PLoS One       Date:  2018-04-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.