The Effect of Implant Failure After Symphyseal Plating on Functional Outcome and General Health.

Bas Frietman1, Jan Verbeek, Jan Biert, Jan-Paul Frölke.   

Abstract

OBJECTIVES: To relate the incidence of implant failure after internal anterior fixation of the pelvic ring to functional outcome and the health-related quality of life in patients.
DESIGN: Retrospective chart and radiographic review.
SETTING: Level I Trauma center.
METHODS: We retrospectively identified all patients who were treated with symphyseal plating for traumatic symphyseal diastasis between January 2003 and December 2013. Patients were asked to complete 2 questionnaires, the SF-36 and the Majeed score. A retrospective chart and radiographic control review were performed on all patients. The following data were collected: demographic data and details regarding the pelvic surgery. Computed tomograms were used to determine fracture classification and quality of reduction. Conventional radiographic follow-up were used to detect implant failure.
RESULTS: A total of 37 patients enrolled the study. Implant failure occurred in 11 (30%) patients resulting in the identification of 2 groups, "implant failure" (n = 11) and "intact implants" (n = 26). The baseline characteristics were equal in both groups. The analysis of the questionnaires revealed that the SF-36 score was not significantly different in any of the dimensions between the both groups. Patients in the implant failure group scored higher on all of the Majeed items, including the total Majeed score, but the difference did not reach statistical significance of P < 0.05.
CONCLUSIONS: Our study showed comparable results regarding the general health measured by the SF-36 for both groups and higher Majeed scores for patients with implant failure compared with patients with intact implants. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2016        PMID: 26655520     DOI: 10.1097/BOT.0000000000000501

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  4 in total

1.  INFIX versus plating for pelvic fractures with disruption of the symphysis pubis.

Authors:  Rahul Vaidya; Adam Jonathan Martin; Matthew Roth; Kerellos Nasr; Petra Gheraibeh; Frederick Tonnos
Journal:  Int Orthop       Date:  2017-01-11       Impact factor: 3.075

2.  Fixation failure in patients with traumatic diastasis of pubic symphysis: impact of loss of reduction on early functional outcomes.

Authors:  Claudio Rojas; Ernesto Ewertz; Jose Miguel Hormazábal
Journal:  J Orthop Surg Res       Date:  2021-11-06       Impact factor: 2.359

3.  Functional outcome of unstable pelvic fractures treated in a level III hospital in a developing country: a 10-year prospective observational study.

Authors:  Chunteng Theophile Nana; M A Ngo-Yamben; Pius Fokam; Ali Mahamat; F M Bombah; M Ekani Boukar; Muluem Kenedy; A Chichom-Mefire
Journal:  J Orthop Surg Res       Date:  2022-04-04       Impact factor: 2.359

4.  Plate fixation of the anterior pelvic ring in patients with fragility fractures of the pelvis.

Authors:  Michiel Herteleer; Mehdi Boudissa; Alexander Hofmann; Daniel Wagner; Pol Maria Rommens
Journal:  Eur J Trauma Emerg Surg       Date:  2021-03-11       Impact factor: 2.374