Literature DB >> 26654141

Effect of Different Torque Settings on Crack Formation in Root Dentin.

Asım Dane1, Ismail Davut Capar2, Hakan Arslan3, Merve Akçay4, Banu Uysal2.   

Abstract

INTRODUCTION: The aim of the present study was to observe the incidence of cracks in root canal dentin using the ProTaper Universal system (Dentsply Maillefer, Ballaigues, Switzerland) at low- and high-torque settings.
METHODS: Sixty-nine mandibular premolar teeth that had been extracted for different reasons were selected. The teeth were divided into 3 groups: an unprepared control group, a low-torque settings group (SX = 3, S1 = 2, S2 = 1, F1 = 1.5, F2 = 2, F3 = 2, F4 = 2 N/cm), and a high-torque settings group (SX = 4, S1 = 4, S2 = 1.5, F1 = 2, F2 = 3, F3 = 3, F4 = 3 N/cm). After a root canal procedure, all the teeth were horizontally sectioned at 2, 4, 6, and 8 mm from the apex. Then, under a stereomicroscope, all the slices were examined to determine the presence of cracks. A chi-square test was used for data analysis. The significance level was set at P = .05.
RESULTS: There were no cracks in the unprepared control group. Vertical root fractures were not observed in any of the groups. There were significantly fewer cracks (17.4% of the sections) in the low-torque group than in the high-torque group (29.4% of the sections) (P < .05).
CONCLUSIONS: In this in vitro study, the instrumentation of root canals with the ProTaper Universal instrument caused more crack formation in root canal dentin at high-torque than at low-torque settings.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cracks; ProTaper Universal; controlled memory; dentinal damage; root canal instrumentation; root fracture; rotary nickel-titanium instruments

Mesh:

Substances:

Year:  2015        PMID: 26654141     DOI: 10.1016/j.joen.2015.10.024

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Influence of Optimum Torque Reverse Motion on Dentinal Cracks after Root Canal Preparation with Two Nickel-Titanium Rotary Systems.

Authors:  Maram Khallaf; Reham Hassan
Journal:  Contemp Clin Dent       Date:  2022-06-21

2.  In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation.

Authors:  Gianluca Gambarini; Massimo Galli; Marco Seracchiani; Dario Di Nardo; Marco A Versiani; Lucila Piasecki; Luca Testarelli
Journal:  Eur J Dent       Date:  2019-12-31

3.  Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM.

Authors:  Sanjib Das; Prasanti Kumari Pradhan; S Lata; Sachidananda Prasad Sinha
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

4.  Ex-Vivo Comparison of Torsional Stress on Nickel-Titanium Instruments Activated by Continuous Rotation or Adaptive Motion.

Authors:  Joo Yeong Lee; Sang Won Kwak; Jung-Hong Ha; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

5.  Comparative evaluation of dentinal crack formation after root canal preparation with Neoendo Flex and Mani Silk files: An in vitro study.

Authors:  Ananya Guha; Richa Pandharikar; Shreya Shivangi; Rahul D Rao; Meenakshi Verma; Ashish K Jain
Journal:  J Conserv Dent       Date:  2021-02-10

6.  Dynamic torque analysis of rotary and reciprocating instruments during root canal instrumentation in simulated canals by an endodontist or a general dentist.

Authors:  Marco Antonio Z Loureiro; Giampiero Rossi-Fedele; Octavio G Amezcua; Paulo O Carmo Souza; Julio A Silva; Carlos Estrela; Daniel A Decurcio
Journal:  J Conserv Dent       Date:  2020-11-05

7.  Longitudinal craze line propagation in human root dentin after instrumentation with NiTi rotary files of different instrument tapers after long-term chewing simulation.

Authors:  Marie-Therese Heberer; Hubert C Roggendorf; Franz-Josef Faber; Nicolai-Alexander Lawrenz; Roland Frankenberger; Matthias J Roggendorf
Journal:  Clin Oral Investig       Date:  2021-11-17       Impact factor: 3.573

8.  Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study.

Authors:  Galvin Sim Siang Lin; Kiran Prabhakar Singbal; Tahir Yusuf Noorani; Raghavendra Penukonda
Journal:  Odontology       Date:  2021-07-16       Impact factor: 2.634

Review 9.  Torque Generation of the Endodontic Instruments: A Narrative Review.

Authors:  Sang Won Kwak; Ya Shen; He Liu; Hyeon-Cheol Kim; Markus Haapasalo
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.