Literature DB >> 26652454

A high sensitive label-free immunosensor for the determination of human serum IgG using overoxidized polypyrrole decorated with gold nanoparticle modified electrode.

Mahmoud Amouzadeh Tabrizi1, Mojtaba Shamsipur2, Ali Mostafaie3.   

Abstract

Herein, an electrochemical human immunoglobulin G (HIgG) immunosensor was fabricated using overoxidized polypyrrole decorated with gold nanoparticle (OPPy-Aunano) modified screen printed electrode (OPPy-Aunano/SPE). The results clearly demonstrate that OPPy-Aunano film is very permeable to [Fe(CN)6](3-/4-). Therefore, the fabrication of immunosensor based on permeability of OPPy-Aunano film to [Fe(CN)6](3-/4-) probe is a novel strategy for the fabrication of label free electrochemical immunosensor. The electrochemical impedance spectroscopy (EIS) techniques are used for the determination of HIgG in the concentration range 0.5 to 125.0ngmL(-1) and with a limit of detection of 0.02ngmL(-1), respectively.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  EIS; HIgG; Immunosensor; Label-free method; OPPy-Au(nano)

Mesh:

Substances:

Year:  2015        PMID: 26652454     DOI: 10.1016/j.msec.2015.10.093

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  7 in total

Review 1.  Recent Advances in Electrochemical Immunosensors.

Authors:  Benoît Piro; Steeve Reisberg
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

2.  An electrochemical aptamer-based assay for femtomolar determination of insulin using a screen printed electrode modified with mesoporous carbon and 1,3,6,8-pyrenetetrasulfonate.

Authors:  Mahmoud Amouzadeh Tabrizi; Mojtaba Shamsipur; Reza Saber; Saeed Sarkar; Maryam Besharati
Journal:  Mikrochim Acta       Date:  2017-12-18       Impact factor: 5.833

Review 3.  Overoxidation of Intrinsically Conducting Polymers.

Authors:  Rudolf Holze
Journal:  Polymers (Basel)       Date:  2022-04-13       Impact factor: 4.967

4.  A voltammetric immunoassay for the carcinoembryonic antigen using a self-assembled magnetic nanocomposite.

Authors:  Li Liu; Guanhui Zhao; Yueyuan Li; Xuan Li; Xue Dong; Qin Wei; Wei Cao
Journal:  Mikrochim Acta       Date:  2018-07-24       Impact factor: 5.833

5.  Ratiometric ultrasensitive electrochemical immunosensor based on redox substrate and immunoprobe.

Authors:  Zhongxue Tang; Zhanfang Ma
Journal:  Sci Rep       Date:  2016-10-14       Impact factor: 4.379

6.  Toward a Practical Impedimetric Biosensor: A Micro-Gap Parallel Plate Electrode Structure That Suppresses Unexpected Device-to-Device Variations.

Authors:  Haruka Honda; Yusuke Kusaka; Haiyun Wu; Hideaki Endo; Daiju Tsuya; Hitoshi Ohnuki
Journal:  ACS Omega       Date:  2022-03-23

7.  A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor.

Authors:  Sopit Phetsang; Duangruedee Khwannimit; Parawee Rattanakit; Narong Chanlek; Pinit Kidkhunthod; Pitchaya Mungkornasawakul; Jaroon Jakmunee; Kontad Ounnunkad
Journal:  Front Chem       Date:  2021-05-20       Impact factor: 5.221

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.